Home Companies Shanghai Zhoubo welding & cutting technology CO.,LTD.

Komatsu Gas Guide A 969-95-24320 For Komatsu Plasma Cutting Machine Consumables

Shanghai Zhoubo welding & cutting technology CO.,LTD.

Contact Us

[China] country

Trade Verify

Contact name:

Inquir Now

Shanghai Zhoubo welding & cutting technology CO.,LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Komatsu Gas Guide A 969-95-24320 For Komatsu Plasma Cutting Machine Consumables

Country/Region china
InquireNow

Product Details

Komatsu Gas Guide A 969-95-24320 For Komatsu Plasma Cutting Machine Consumables
 
We are a professional manufacturer of plasma cutter consumables.
1. Can supply various models of plasma Consumables electrode, nozzle, shield, swirl ring, inner cap, retaining cap, water tube, torch body, such as HT4400, HPR400XD, HPR260XD, HPR130XD, HPR260, HPR130, HSD130, HD3070, HD4070, HT2000, MAX200, POWERMAX1650, POWERMAX1250, POWERMAX65, POWERMAX85, POWERMAX45, POWERMAX30 and so on.
 
2. Can make as per customer's requirements. Almost Every Parts Have A Lot Of Stock.
3.The strict quality control. Our products processed are using CNC machines, we have fifteen sets of high-precision testing equipment and Eighty experienced skilled workers.
 
4. Welcome to contact us. You Can Send Us E-Mail, Skype, WhatSapp, Wechat or Call us.
5.Outer packing:standard export carton.
6.Have any questions, pls feel free to inform us.
Customer Satisfaction
If you worry about our products’ quality, I can give you some samples to test by free. Please don't hesitate to contact us if you have any questions or concerns before or after your purchase. We are committed to your 100% satisfaction.
Shipping and handing
1. DHL is our preferred shipping method. Meanwhile TNT, EMS, Fedex, UPS are available.
2. Make sure to leave telephone number when filling your buyer information.
3.You can check the goods where it is in transit through tracking NO .
Refund(Echange Only)
1.If you are not satisfied with your purchase, you can echange the items received. you must contact us within 5 days of the receipt
of your order. And you should pay all additional shipping fees incurred and the items returned should be kept in their original
status.
2.If you wish to echange defective or incorrect shipped goods, please contact us within 5 days after receiving the goods.
Notes
1. The buyer are responsible for any insurance you think necessary.
2. The processing time for a specific order varies with the product type and stock status. Mostly, processing time can be 3 to 15 working days.
Feedback
1.Since your feedback is very important to our business's development, we sincerely invite you to leave positive feedback for us if
you are satisfied with our product and service. It'll just take you 1 minute.
2.Please contact us before leaving any negative or neutral feedback. We will work with you to solve any problems.Thank you!

 

MachineHEC NO.Ref NO.Description
30KWL41470969-95-24470Outer Cap
L21750969-95-24750Shield Cap (<t6mm)
L21810969-95-24810Shield Cap (>t6mm)
L31141969-95-24141Ring
L11130969-95-24130Nozzle 1.3mm
L11190969-95-24180Nozzle 1.1mm
L11180969-95-24190Nozzle 0.8mm
L11770969-95-24770Nozzle 0.6mm
L71320969-95-24320Guide A (Nozzle 1,3,1,1mm)
L71780969-95-24780Guide B (Nozzle 0.8,0.6mm)
L01310969-95-24310Electrode
L91410969-95-24410Shim for Outer cap
L91162969-94-24162Center pipe
L91163969-94-24163Center pipe
L81311969-94-24311Torch Body Kit
L81312969-94-24312Torch Body Kit
L90990969-95-10990Cooling water
L01910969-95-24910Electrode
L11920969-95-24920Nozzle 1.6
L11930969-95-24930Nozzle 1.4
L21950969-95-24950Shield Cap 1.6
L21960969-95-24960Shield Cap 1.4
    


 
Technical Support:
Common problems in the application of plasma cutting machine
 
Plasma cutting electrical arc stability directly affect the cutting quality, plasma arc unstable phenomenon, lead to incision is uneven, product of melanoma defects, may also lead to the decrease of the control system of the related components life, nozzle and electrode frequent replacement. In view of this phenomenon, analyze and propose solutions.
1 low pressure
"Plasma cutting machine work, such as work pressure far below specifications required pressure, which means of the arc plasma jet velocity weakening, input the air flow is less than the specified value, this form of high energy and high speed of plasma arc, causing the incision quality is poor, cut through, incision tumor of the product phenomenon. Insufficient pressure of the reasons are: air compressor input, cutting machine, air regulator low voltage, electromagnetic valve oil, gas path is obstructed etc..
"The solution is, before use to observe the air compressor output pressure display, if not meet the requirements, adjust the pressure or the maintenance of air compressor. If the input pressure has reached the requirements, should be properly adjusted check air filter relief pressure valve, gauge display can meet the cutting requirements. Otherwise deal with air filter relief pressure valve for routine maintenance, ensure that the air dry, no oil. If the input can cause poor air quality, oil solenoid valve, the valve opening, the valve port is not fully open. In addition, torch nozzle pressure is too low, also need to replace the solenoid valve; gas road section variable is caused by pressure is too low, according to the specifications for tracheal replacement.
2 high pressure
"If the input air pressure far exceed 0.45MPa, after the formation of the plasma arc, the large flow of air will blow concentrated arc column, the energy of arc column dispersion, decreased the plasma arc cutting intensity. Cause the pressure is too high, the reasons are: improper input air conditioning, air filter regulator is too high or air filter valve failure.
The solution is to check whether the pressure of the air compressor is adjusted properly, air compressor and air filter pressure relief valve is dysfunctional. After startup, such as rotating air filter relief pressure valve adjusting switch, gauge unchanged, indicating that the air filter relief pressure valve failure, need to be replaced.
3 cutting torch nozzle and electrode
"Since the nozzle installation is improper, such as threads are not tightened, equipment of each block bit improper adjustment, need water cooling of the torch at work, not in accordance with the requirements of pass into the flow of cooling water and frequent arcs, will cause premature failure of the nozzle.
"The solution is, in accordance with the requirement of technology of the workpiece cutting and the correct adjustment of equipment gear, check the torch nozzle is installed firmly is, through the cooling water nozzle should be made in advance in cooling water circulation up. When cutting, cutting torch and workpiece thickness adjustment according to workpiece distance.
4 input AC voltage is too low
Plasma cutting machine using the site has a large power use facilities, cutting machine internal main circuit components, etc., will make the input AC voltage is too low.
The solution is to check whether there is sufficient capacity of the plasma cutting machine access to the power grid, the power line specifications are in line with the requirements. Plasma cutting machine installation location, should be far away from large electrical equipment and often have electrical interference place. The use of the process, to regularly clean the dirt and dust cutting machine components, check the wiring is aging etc..
5 poor contact with the ground
"The ground is essential preparation before cutting work a. Without the use of special grounding tool, workpiece surface insulation and long-term aging serious ground, will cause poor contact with the ground.
Should use special grounding tool, and check whether the insulation effect of the ground contact with the workpiece surface, avoid the aging ground.
 

Hot Products

Powermax1250 Shield Cap 120930 / 120929 Plasma Cutter Consumables We can offer you all plasma ...
Powermax1650 Shield Cap 220047 Plasma Cutter Consumables We can offer you all plasma consumables for ...
Electrode 120926 Powermax1250 Plasma Consumables For Plasma Cutting Machine We can offer you all ...
Powermax1250 Nozzle 120927 Plasma Consumables For Plasma Cutting Machine We can offer you all plasma ...
Nozzle 220011 Plasma Consumables For Powermax1650 Plasma Cutting Machine We can offer you all plasma ...
Electroce 220037 PowerMax1650 / PowerMax1250 Plasma consumables We can offer you all plasma ...