Home Companies Hangzhou Hangyang Cryogenic Liquefaction Equipment Co., Ltd

Cryogenic Air Separation Plant Nm3/h KDON -1600 / 5600 ASU Molecular Sieve

Active Member

Contact Us

[China]

Address: No.592 Zhongshan North Road, Hangzhou, China

Contact name:Lou Yizhen

Hangzhou Hangyang Cryogenic Liquefaction Equipment Co., Ltd

Cryogenic Air Separation Plant Nm3/h KDON -1600 / 5600 ASU Molecular Sieve

Country/Region china
City & Province hangzhou zhejiang

Product Details

 

Cryogenic Air Separation Plant Nm3/h KDON-1600/5600 ASU Molecular Sieve

 

Specifications:

 

Standard Product for Cryogenic Air Separation Plant KDON 40~3860 Nm3/h (GAN)

 

MODEL

CONTENTS  

KDON-1600 (50Y)/5600(50Y)

KDON-1540/3860

KDON-1700/1700

KDON-1700(120Y)/40Y

KDON-1800(40Y)/40Y

GOX flow

Nm3/h

1600

1540

1700

1700

1800

LOX flow

 

50Nm3/h

/

/

120Nm3/h

40Nm3/h

GOX purity

%

99.6%

≥95%O2

≥99.5%O2

99.5%O2

99.5%O2

LOX purity

%

99.6%

/

/

99.6%

99.6%

 GOX pressure

kPa

150

25

20

15

15

LOX pressure

kPa

200

/

/

150

150

GAN flow

Nm3/h

5600

3860

1700

/

/

LIN flow

 

50Nm3/h

/

/

40Nm3/h

40Nm3/h

GAN  purity

%

≤3ppm O2

≥95%O2

≤10ppmO2

/

/

LIN purity

%

≤3ppm O2

/

/

≤5ppmO2

≤5ppmO2

 GAN pressure

kPa

29

10

15

/

/

LIN pressure

kPa

400

/

/

200

200

 

 

Typical Product: KDON-1500(30Y)/1000(30Y) Cryogenic Air Separation Plant

 

Output, purity and pressure

 

Product

Output (Nm3/h)

Purity

Pressure kPa(G)

GOX

1500

99.6%

30

LOX

30

99.6%

150

GAN

1000

≤5ppm O2

15

LIN

30

≤5ppm O2

200

 

 

Description:

 

      1. Feed air compression, pre-cooling and purification systems

      Feed air from atmosphere is removed dust and mechanical impurity through air filter then enters into Air Compressor. Compressed air is sent into Air Pre-cooling System to be cooled.

Cooled air enters into Molecular Sieve Purification System for adsorption where moistures, carbon dioxide, acetylene and other hydrocarbons impurities are adsorbed. There are two alternative working adsorbers. When one adsorber works, the other is in regeneration.

 

      2. Air rectification

     Purified air from Molecular Sieve Purification System is sent into Main Heat-exchanger in where the purified air is cooled down by reflux cryogenic flow to saturation, and then flows into rectification column.

 

     The liquid air we got in the bottom of column is sent to condenser-vaporizer on the top of column as condensate liquid after throttling. The oxygen enriched liquid air in the condenser -vaporizer is sent to main heat exchanger and rewarmed and then goes into turbo expander for expansion. The oxygen enriched air returns back to the cold end of heat exchanger after expansion, where oxygen enriched air is rewarmed to normal atmospheric temperature and then goes out of cold box. Part will be used as regeneration gas and other will be vent.

 

     The product nitrogen drawn from the top of column flows to heat exchanger for rewarming and then send out of cold box to nitrogen consumer.

 

 

 

Applications:

  1. We supplied many countries (USA, Germany, Mexico, Indonesia, North Korea, Kazakhstan, Iran, Saudi Arabia, Egypt, Brazil, Hungary, Malaysia, Czech, Switzerland, Spain, Myanmar, Vietnam, Thailand, Russia, Mongolia, Syria, India, etc.)
  2. Pharmaceutical and biotechnology
  3. Papermaking
  4. Glassmaking
  5. Petroleum and natural gas

 

Competitive Advantage:

  1. Our company owns the most advanced technological level
  2. Powerful manufacturing capacity
  3. Short time delivery
  4. Good service
  5. No gas loss and high yield
  6. Low Maintenance Cost

 

 

Hot Products

2000~3000Nm3/h Series Liquid Air Separation Plant KDONAr-3000Y/4750Y/100Y, LOX, LIN, LAr, Industry ...
Cryogenic Air Separation Plant 1250/2000 Nm3/h KDON-1250/2000 Standard Gas Industry Liquid ...
Cryogenic Air Separation Plant 200/100Y/25Y Nm3/h KDON-200/100Y/25Y Steelmaking Industry Balance Gas ...
Cryogenic Air Separation Plant Nm3/h KDON-350/900 Process Gas Liquid Nitrogen Oxygen Gas Specificati...
Cryogenic Air Separation Plant KDON-400/2500 Nm3/h Petroleum and natural gas Specifications: ...
Cryogenic Air Separation Plant Nm3/h KDON-1600/5600 ASU Molecular Sieve Specifications: Standard ...