GC-MS 6800 Gas Chromatograph Mass Spectrometer(GC-MS Analysis)
 
 
 
Introduction
 
GC-MS 6800 GC-MS Analysis is a cost-effective gas chromatograph mass spectrometer.
GC-MS 6800 GC-MS Analysis holds several patented technologies, and are widely used in industrial inspection, food hygiene, environmental protection, etc.
 
 
Hardware
 
Electronic pressure/flow control system (EPC/EFC) for self-developed GC 6800 system;
Patented EI filament set provides highly efficient electron emission, a maximum of 350μA;
Quality mass analyzer with pre-filter reduces quadrupole pollution;
High-energy dynode electron multiplier ensures good sensitivity;
Vacuum system with quality mechanical and turbo molecular pumps guarantees stability and reliability;
Full scale gauges monitor vacuum states in real time;
Self protection system guarantees safety of operators and core parts under abnormal conditions;
RF power supply digital compensation technology ensures better sensitivity and resolution in full mass range.
 
 
Software
 
The software “ChemAnalyst” controls auto sampler (AS), gas chromatograph (GC) and mass spectrometer (MS); data are acquired and transferred by high-speed network card;
Full Scan and selective Ion Monitoring (SIM) modes are available;
the system supports manual and automatic tuning, display of total ion current (TIC) and mass chromatogram (MC);
Skyray Instrument is the only legal distributor authorized by NIST/EPA/NIH in China mainland, which guarantees the latest version and free online upgrade of NIST (current version NIST 2011).
The data processing section searches target compounds in NIST 2011 based on mass spectra of samples, displays search results which include retention times, structural formula and standard mass spectra, and compares the abundances of standard and real target ions. Users can make accurate qualitative and quantitative analyses;
Superior quality: it uses high-end core parts, which ensures GC-MS 6800 high quality.
Meeting high demands: Skyray provides necessity parts, and meets multiple requirements from clients in different fields;
User-friendly design: it facilitates easy operation and convenient maintenance;
High-efficiency ionization source: modularization design, employing Skyray patented ion source, having high ionization efficiency, and enhancing sensitivity;
ChemAnalyst software: convenient operation, data acquisition and processing;
Highly cost-effective: offering more benefits while meeting all application demands;
Scientific solutions: We offer customers perfectly customized solutions;
Consumables with favorable price: most consumables and parts are self-developed, which save a lot of maintenance cost, while providing high performance;
Satisfactory post-sale service: Skyray makes a quick response to client’s demands, with professional technicians offering 24-hour services.
 
 
GC Specification
 
Inlet temperature: Max. 450oC
Pressure range: 0-100psi,±0.002psi
Pressure control mode: Electronic pressure control (EPC), support CV and CC
Split mode: Split/splitless, max. split ratio: 1000:1
Column oven working temperature: Room temperature+4°C~450°C
Heating rate: Up to 120°C/min
Temperature programming: 7 stages/ 8 platforms
Auto Sampler: Optional
 
 
MS Specification
 
EI source ionization energy: 5 eV ---250 eV (Adjustable)
Mass range: 1.5- 1000amu
Resolution: Unit resolution (full width at half maximum)
Ion source temperature: 100—350°C
Filament emission current: 0-350 μA
GC-MS Interface Temperature: Max. 450°C
stability: ±0.10 amu/48 hrs
Sensitivity: Full scan, 1pg OFN at m/z 272 with S/N ≥30:1 (RMS)
Scan rate: Up to 10000 amu/s
Vacuum: Turbo molecular pump(67 L/s)
Detector: High-energy dynode electron multiplier
 
 
Current Customers
 
1. Industrial inspection: textile, electricity & electronics, plastic cement, cosmetics;
2. Food hygiene: pesticide residues, flavors and fragrances;
3. Environmental protection: air, water, soil, solid waste;
4. Pharmaceutical: pharmaceutical industries, drug inspection;
5. Petrochemical: oil refineries, chemical plants;
6. Public security organ: explosives, forensic evidence
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 





























































































































































Hot Products

GD-752N Lab Multifunctional UV-Visible Spectrophotometer by UV-vis Spectrophotometry Characteristics...
GD-752N Ultraviolet and Visible Spectrophotometer for Quantitative Analysis Characteristics: The ...
EDX1800B Professional XRF RoHS/Precious Metals Analyzer Introduction • EDX1800B X-ray Fluorescence ...
GC-MS 6800 Gas Chromatograph Mass Spectrometer(GC-MS Analysis) Introduction GC-MS 6800 GC-MS ...
GC-MS 6800 Gas Chromatograph Mass Spectrometer(GC-MS Analysis) Introduction GC-MS 6800 GC-MS ...
LC-310 High-performance Liquid Chromatograph with Wide Application Performance Characteristics LC...