Home Companies Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

Copper 6/10 (12 ) KV 3 Core XLPE Insulated Cable MV Power Cables Screened Unarmored Electrical Cable

Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Chengtiantai industry park, Bahang road, Lisonglang community, Gongming block, Guangming district, Shenzhen city, Guangdong province, China.

Contact name:Alex Xie

Inquir Now

Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Copper 6/10 (12 ) KV 3 Core XLPE Insulated Cable MV Power Cables Screened Unarmored Electrical Cable

Country/Region china
City & Province shenzhen guangdong
Categories Power Cables
InquireNow

Product Details

6/10(12)kV 3 core XLPE Insulated Medium Voltage Power Cable

 

Introduction

 

XLPE Insulated, Copper conductor, 3 core, screened, PVC sheathed

 

The 3 cores copper conductor XLPE Insualted screened unarmoured cables are designed for distribution of electrical power with nominal voltage Uo/ U: 6/10 KV and frequency 50Hz.

 

Copper Conductor XLPE MV power cables are widely used in the building and construction, renewable energy, and power transmission industries where the cables can be laid directly into the ground or cable ducts.

 

  CONSTRUCTION:

1. CONDUCTOR

– Bare copper class 2 to IEC 60228, round, multiwire stranded and compact

2. CONDUCTOR SCREEN

– Inner semi-conducting coating

3. INSULATION

– Core insulation of cross-linked polyethylene (XLPE)

4. INSULATION SCREEN

– Outer conductive layer extruded and per-manently welded with the core insulation

Semi-conducting type
– Over the outer semi-conducting layer, a semiconducting tape must be used.

5. METAL SCREEN

– copper tapes helically with a minimum thickness of 0,1 mm.

Separator
– Over the screen as well as under outer sheath, a separating layer must be used (e. g. taping).

6. FILLER

– PP filler

7. WRAPPING TAPE

8. SHEATH

– Outer sheath of PVC compound

Core identification:

– colored tapes under screen.

  STANDER

International:IEC60502-2

National:GB/T 12706.1-2008

  TECHNICAL DATA

Temperature range
– during installation up to -5°C

 

Operating temperature
– max. +90°C

Short circuit temperature
+250°C (short circuit duration max. 5 s)

 

Minimum bending radius
– 15 x cable Ø

Tensile strength:

– min. 12,5 N/mm2

Nominal voltage
– U0/U 6/10 kV

 

Operating voltage, 50 Hz
– for 6/10 kV = max. 12 kV

 

Test voltage(V/5 min)
– for 6/10 kV = 21 kV

 

Breaking strength:

– min. 200%

 

  6/10 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

 

No.cores x
cross-sec.

Operation
voltage
max.

Nominal
voltage
U0/U

Insulation
thickness

Sheath
thickness
Nominal
value

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

kV

kV

mm

mm

mm

kg / km

A

A

Ω/km

3 x 35 rm

12

6/10

3.4

2.3

42.8

2354

144

184

0.52

3 x 50 rm

12

6/10

3.4

2.4

45.8

2900

174

217

0.39

3 x 70 rm

12

6/10

3.4

2.5

49.7

3350

215

264

0.27

3 x 95 rm

12

6/10

3.4

2.7

53.3

4200

262

317

0.19

3 x 120 rm

12

6/10

3.4

2.8

56.5

5050

303

361

0.15

3 x 150 rm

12

6/10

3.4

2.9

60.2

6000

345

406

0.12

3 x 185 rm

12

6/10

3.4

3.0

63.8

7200

494

459

0.10

3 x 240 rm

12

6/10

3.4

3.1

69.0

9000

464

532

0.08

3 x 300 rm

12

6/10

3.4

3.3

74.1

11183

531

601

0.06

3 x 400 rm

12

6/10

3.4

3.5

84.0

14587

626

690

0.05

 

*Dimensions and specifications may be changed without prior notice.

 

  MEDIUM VOLTAGE CABLE TESTING

 

Routine tests:

Sample tests:

Type tests:

These non-destructive tests are normally carried out on all lengths manufactured.
- Conductor resistivity
- Spark test on oversheath
- Voltage tests on sheath
- D.C. voltage test on oversheath

These potentially destructive tests are normally carried out on every production run.
- Examination of conductor and dimensions
- Hot set test for XLPE insulation
- Insulation and oversheath thickness
- Four hour voltage test

These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
- Electrical type tests including bending and heat cycle
- Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.

 

  Similary Products

 

Copper conductor XLPE Insulated

MV Power Cable

Voltage

Rating

cross-sectional

size ranges

Links

single copper core XLPE insulated with PVC oversheath

3.6/6 kV

35mm2 to 630mm2

view details

6/10 kV

35mm2 to 630mm2

view details

8.7/15 kV

35mm2 to 630mm2

view details

12/20 kV

35mm2 to 630mm2

view details

18/30 kV

50mm2 to 630mm2

view details

3 copper core XLPE insulated with PVC oversheath

3.6/6 kV

35mm2 to 400mm2

view details

6/10 kV

35mm2 to 400mm2

view details

8.7/15 kV

35mm2 to 400mm2

view details

12/20 kV

35mm2 to 400mm2

view details

 

  PACKAGING AND SHIPPING

 

Packaging: steel wooden drum, other as required ; standard delivery length is 300 m

 

Packaging details :

Delivery :

Steel Wooden Drums

Cable Drum In container 

shipped in 15 days after payment

 

  Cable Drum Data

 

CABLE DRUMS

D1=Flange Diameter(mm)

W=Useful Width (mm)

D2=Barrel Diameter(mm)

1000

700

500

1100

700

550

1200

700

600

1400

750

710

1600

900

900

1800

1120

1000

2400

1150

1300

 

 

  Delivery Port:

 

Port of Shenzhen 

Port of Hongkong 

Port of Guangzhou

 

  Shenzhen chengtiantai cable operates certified management systems compliant with:

 

 

Certificat

Information

ISO 9001:2008

Quality management systems

 

Certificat ISO 9001:2008
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 9th January 2022

ISO 14001:2004

Environmental management systems

Certificat ISO 14001:2004

- Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 9th January 2022

OHSAS 18001:2007

Assessment specification for occupational health & safety management systemsenvironmental management systems

Certificat OHSAS 18001:2007
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 9th January 2022

 

  Manufacturing Process Of Medium Voltage Power Cable

 

1. copper rod

2. wire drawing

3. wire stranding

4.Triple Extrusion Insulation

5.Screening Process

6. outer covering Process

7. Sheath Marking

8. Packaging

9. Partial discharge Inspection

 

  Some great shot on our manufacturing plant

Located in: Chengtiantai Industrial Park, Guangming New District, Shen zhen P. R. China 518106

 

Our production in numbers

 

● Cable production started 1983
● 35 years of cable manufacturing experience

● Sales in 2016 about 500 million USD

● 100,000 m2 Production area
● 350 Will-trained employees
● Exported more than 22 countries
● 2 Manufacturing plant
● 1 R&D Center

● 200 Sets Of Testing Equipment

● 100 Testing Items
● 8 workshop
● 40 wire drawing machines
● 10 bunching machines
● 28 Extruder system
● 42 stranding machines
● 10 Braiding machines

 

 

  RECOMMENDED ORDERING PARAMETERS

  CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

 

  WARRANTY

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

Hot Products

3*240 sq.mm PVC Multi-core cable to IEC 60502-1 Cu-conductor, PVC Insulated and sheathed 0.6/1kV, ...
0.6/1kV, PVC Insulated Cables according to IEC 60502-1 (unarmoured) CTT Power cables for energy ...
Low Voltage STA Armoured Power Cable , LV Electrical Armoured Cable For Switching Stations IEC60502...
Round Standed / Shaped 2 Core PVC Cable , Two Core Power Cable Flameproof Power Cable IEC 60502-1 ...
Electric Cable Durable 600v XLPE Power Cable , 3 Core Copper STA Armoured Cable 3*16sq Mm 3*16sq. mm ...
3*240 sq.mm PVC Multi-core cable to IEC 60502-1 Cu-conductor, PVC Insulated and sheathed 0.6/1kV, ...