QM3G-50FH Plc Automation Control Panel 32bit CPU 408MHz 151*96*36mm Single Phase 6 Channel 60KHz TYPE-C RS232 RS
The all-in-one solution is to integrate the controller, operation interface, input/output, analog input/output, high-speed counting/pulse and communication port into a compact unit to meet the needs of customer equipment automation control.
PRODUCT DESCRIPTION of HMI PLC ALL IN ONE
Feature:
1.32K step program capacity, 32K power-off holding registers, supporting interrupts, linear arc interpolation, and PID self-tuning.
2. Special encryption is possible. The touch screen and PLC can be encrypted separately, and setting the PLC password to 12345678 can completely prohibit reading programs.
[Note: PLC only supports 8-bit password encryption]
3. PLC programming is compatible with software GX Developer 8.86Q and GX Works2, and the touch screen uses TPWorks1.39 editing software.
4. Network modules can be installed according to customer requirements to achieve remote control. More specifications can be customized in bulk.
Model | QM3G-50FH |
Dimension | 151*96*36mm |
Cutout size | 143*86mm |
Input | 24VDC |
Power Consumption | 4-6W |
HMI | |
Feature | 60K colors resistive touch screen, supports portrait display |
Type | 5"TFT |
Display size | 108*65mm |
Resolution(pixels) | 800*480 |
RAM | 64MB (Please inquire if requires storing historical data) |
ROM | NOR Flash 8MB |
CPU | 32bit CPU 408MHz |
COM ports | Type-C HMI download port (can download PLC program through the USB penetrating function), RS232 port |
Software | Coolmay TPWorks HMI Programming Software |
PLC | |
I/O level | - Input: Passive NPN, public terminal isolated - Transistor output: Low level NPN, COM connect to negative - Relay output: Normally open dry contact |
DO type and load |
- MT: 2A/point, 4A/4 point COM, 5A/12 point COM MR: 2A/point, 5A/12 point COM |
High-speed counting | Single phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz, or 2 ABZ 60KHz + 1 AB phase 10KHz |
High-speed pulse (Only for MT models) | 8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz. High-speed counting + high-speed pulse < 480KHz |
COM port | 1x TYPE-C, 1x RS232, 1x RS485 |
Software | Compatible with GX Developer8.86 and GX WORKS 2 |
Detailed info. refer to: “Coolmay QM3G-FH All-in-One User Manual”, “Coolmay CX3G/FX3GC PLC Programming Manual”, “Coolmay TP HMI User Manual” |
Coolmay PLCs are widely used in different automation industries. Their multiple functions, excellent performance, easy installation, etc.. offers customers more conveniences.
1.Precautions of using PLC transistor and relay
The PLC output is a common cathode output, the theoretical value is
1A, the actual use is less than 500mA, the COM wiring is negative,
please use 24V voltage, there is no voltage output when it is used
as a switch. If an external relay, the relay needs an external
power supply.
The relay has a contact life, the theoretical value is 30W times,
and the theoretical value of the external load does not exceed 5A.
Frequently, the full load current may affect the service life, and
there is no voltage out.
2.Precautions of Coolmay PLC output type selection
MT: indicates the transistor output, MR: indicates the relay
output, and MRT: indicates the relay transistor mixed output.
The main differences between transistor output and relay output
are:
(1)The difference in current load. At present, we use a transistor
with a maximum current load of 500MA, and the maximum current load
of the relay is 5A (the maximum relay current of the
EX2N(S)/DX2N(S) series PLC is 3A);
(2)Output power: The transistor can only be connected to the DC24V
power supply , and the relay can be connected to the DC24V and
AC220V power supply ;
(3)Functional characteristics: If you need to send a pulse to drive
a stepper motor, you should use the transistor output or the mixed
output. Also if the output switch is active, it is recommended to
use a transistor output;
(4)If both the relay and the transistor are available, it is
recommended to use a transistor output because the transistor has
no contact life limit and the lifetime will be longer than the
relay as long as the current does not exceed the limit.