2 Position 4 Way Diaphragm Solenoid Valve For Medical Oxygen Generator

Country/Region china
InquireNow

Product Details

Diaphragm Solenoid Valve For Oxygen Generator System Of Medical Industrial

 

 

Two Position Four Way Small Volume Light Weight Oxygen Generator Diaphragm Pilot Valve For Oxygen Machine


0.05Mpa~0.35Mpa Low working pressure two position four way Diaphragm pilot Solenoid valve for application to Oxygen Generator body material aluminum alloy 
 
Quick Detail:

  •  Aluminum alloy material Valve Body.
  •  Completely range of flow rate capacity for Oxygen Generator 1L,2L,3L,5L,8L,10L,20L etc
  •  Small volume in design, light weight for a most compact space-saving for convenient and portable concentrator.
  •  Fast and high sensitive action ensure smooth sustaining compressed clean air inlet and Nitrogen pumping out.
  •  Long service life cycles ,Continuously working at more than 30 Million times

 

Description:

PSA principle medical usage oxygen concentrator

 

Air source is compressed by the air compressor, after dust removal, oil removal, and refrigerated/Adsorption drying, it passes through the diaphragm oxygen concentrator solenoid valve, the oxygen generator diaphragm normally in 4 way or 5 way (dual exhausting type),the compressed and filtrated air enters into the left adsorption Tank, the tank inside pressure increasing, and the nitrogen molecules in the compressed air due to volume size and pressurizing factors, they are adsorbed by zeolite Molecular sieve bedding at the bottom of adsorption tank , the un-adsorbed oxygen molecules passes through the adsorption molecular sieve bed, enters into oxygen storage tank. This process is called left adsorption.

 

After the left adsorption process is over, the left and right adsorption tanks connected by a valve to balance the two tank inner pressure, actually the left tank high pressure drop equal to the right tank inner pressure. This process is called pressure equalization, and the duration is about 3-5 seconds. After the pressure equalization process is over, the compressed clean air passes through the diaphragm oxygen generator solenoid valve, and enters into the right adsorption column and inside the adsorption column pressure increasing. The nitrogen molecules of the air are adsorbed by zeolite Molecular sieve bedding at the bottom of right adsorption column, oxygen molecules due to size of volume could not be adsorbed, it will pass through the molecular sieve bed and enters into the oxygen reservoir tank. This process is called right adsorption ,it lasts for tens of seconds. At the mean time, the nitrogen molecules which adsorbed in the zeolite molecules of the left adsorption tower is released because of depressurizing state in the tower, pumps out and exhausting to atmosphere, This process is called desorption, desorption process result in the starting over and renew capacity of zeolite molecular sieve in the tower, VICE VERSA, When the left adsorption tower is adsorbed, the right adsorption tower is desorbed. In order to completely exhausting the nitrogen released from the molecular sieve to the atmosphere, the oxygen The desorption tower is blowed through a normally open back-flush valve. This process is called backflushing. It carries out at the same time with desorption. After the right adsorption is completed, it runs the process of pressure equalization, and after that comes the process of switching to the left adsorption, so on the system continues to circulate, which enable high-purity and big flow oxygen to be produced continuously.

 

Applications:
DSV series Diaphragm solenoid valve used in the low pressure system especially use for Oxygen Generator system of medical Industrial
 

Ordering Code:

DSV3R5LDC12V 
DSV:DSV Series 4/2 Diaphragm Solenoid valveSize Code

Applicable Oxygen Generator Flow Capacity

 

12VDC/24VDC

Customized Code

Blank: Not Specific


Specification:

Model noDSV-3R-5L-DC12V
Working MediumCompressed Filtered Clean Air
Body MaterialAluminum Alloy
Position And Way NumbersTwo Position Four Way
Coil VoltageStandard:12VDC/24VDC
Motion PatternDiaphragm Pilot
Working Pressure0.05~0.35MPa
Operating Temperature-20~70℃
Voltage Tolerance±10%
Insulation&Protection ClassF Class IP65



Pneumatic valve,Diaphragm solenoid valve,Oxygen Generator Solenoid valve

Hot Products

Vacuum Generator Vacuum Ejector Pump Compressed Air Vacuum With Nozzle And Muffler NV series vacuum ...
4.5Bar - 5.0 Bar Multistage Energy Saving Vacuum Pump , Vacuum Generator TM Series Multistage type ...
4Bar - 6 Bar Multistage Compact mini Vacuum Pump , Vacuum Generator BM Series Multistage vacuum pump ...
0.4Mpa- 0.6 Mpa Multistage Energy Saving Vacuum Pump , Vacuum Generator VTS Series Multistage type ...
Pneumatic Stainless Steel Pneumatic Angle Seat Valve With Stainless Steel Polished Actuator ESV ...
DN15-DN100 2 Way Stainless Steel Pneumatic Actuated Flange Ball Valve 2 way double flange stainless ...