Hot Sale Snl7 3p Series (MCB) Miniature Circuit Breaker 63A 10ka​

 

GENERAL
 

SNL7 series high breaking capacity mini circuit breaker is used in AC50/60Hz, rated voltage of 230V

3, 4 poles 400V, rated current to 63A for overload and short-circuit protection as well as for unfrequented switching under normal case.It is used extensively for industry, commercial and household.This product conform to IEC60898 standard.

 

 1.Application:For protecting cables and equipments against overload and short circuit.

 2.General rules for choosing MCB.

      a.Technical data of the network at the point considered

The earthing systems,short-circuit current at the circuit breaker installation point,which must always be less than the breaking capacity of this device,network normal voltage.

      b.There are 3 curvve characteristics for magnetic operation:

B curve (3-5In) protection and control of the circuits against length cables in TN and IT systems.

C curve (5-10In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.

D curve (10-14In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps.)

 

Advantages:


 

High breaking capacity , all rated current can reach 6KA;


Many kinds of accessories can be chosen, in modularize and flexibility combine that make the customer install conveniently;


The cover and function parts both are made of inflaming retarding, bear high temperature and bear impact plastic;


The breaker is applicable to lighting distribution system in industrial enterprise, commercially district, high-rise building and dwelling house.

 

 

Specifications

 

 

Model

SNL7
Pole1p,2p,3p,4p
Rated Current(In)1,2,4,6,10,16,20,25,32,40,50,63A
Rated Voltage(Un)AC230(240)/400(415)V
Rated Frequency50/60HZ
Tripping curveB,C,D
Magnetic releasesB curve: between 3and 5 In
C curve: between 5and 10In
D curve: between 10 and 14In
Electro-mechanical enduranceover 6000 cycles

 

 

 Standard IEC/EN 60898-1
Electrical
features
Rated current InA1,2,4,6,10,16,20,25,32,40,50,63
PolesP1,2,3,4
Rated voltage UeVAC 240/415
Insulation voltage UiV500
Rated frequencyHz50/60
Rated breaking capacityA45,006,000
Rated impulse withstand voltage(1.2/50)UimpV4000
Dielectric test voltage at ind.Freq.for 1 minKv2
Pollution degree 2
Thermo-magnetic release characteristic B,C,D
Mechanical
features
Electrical lifet4000
Mechanical lifet10000
Protection degree IP20
Reference temperature for setting
of thermal element
30
Ambient temperature
(with daily average ≤35℃)
-5~+40(Special application please refer to
temperature compensation correction)
Storage temperature-25~+70
InstallationTerminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cablemm225
AWG18-3
Therminal size top/bottom for busbarmm225
AWG18-3
Tightening torqueN*m2
In-lbs18
Mounting on DDIN rail EN 60715(35mm)by means of fast clip device
Connection From top and bottom

 

Product Usage:

 

 

General rules for choosing MCB,For protecting cables and equipments against overload and short circuit.

 

a. Technical date of network at the point considered:

The earthing systems,short-circuit current at the circuit breaker installation point ,which must always be less than the breaking capacity of this device,network normal voltage.

 

b. There are 3 curve characteristics for magnetic operation:

B curve (3-5 ln) protection and control of the circuits against length cables in TN and IT systems.

C curve (5-10 ln) protection and control of the circuits against overloads and short-circuits; protecton for resistive and inductive loads with low inrush current.

D curve (10-20 ln) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps)

 

 

Our services have competitively price,we can provide after sale service,our product quality are very good,it has a long life<br>

Hot Products

2 Pole ELCB Earth Leakage Circuit Breaker , White Voltage Operated ELCB GENERAL STG series ...
BHC Adjustable ELCB Circuit Breaker 4 Pole 300 Ma NFC61450 Fixed Install GENERAL STG series ...
Pg Series Adjustable RCBO 4pole Earth Leakage Circuit Breaker NFC61450 NFC62411 IEC60947. GENERAL An ...
Adjustable Current ELCB Circuit Breaker NFC61450 / NFC62411 IEC60947 Standard GENERAL An Earth...
Hot Sale Snl7 3p Series (MCB) Miniature Circuit Breaker 63A 10ka​ GENERAL SNL7 series high breaking ...
Stm13-63 Series ( MCB ) MINIATURE CIRCUIT BREAKER Protection circuit STM13-63 series high breaking ...