Hunan Lanly Network Technology Co., Ltd. |
|
Putzmeister Concrete Boom Pump 736
1. Putzmeister 42 meters concrete pump, Volvo chassis, 4 axle
x-leg, classical 4 booms, high working stability.
2. Manufacture Date is November of the year 2005.
3. Maintenance completed new tires of the complete machine. Hopper
maintenance; Finishing lubrication pipeline, circuit, and hydraulic
circuit. Whole line arrangement, old pipe and line changed,
pressure debugging for 8 hrs and in very excellent condition.
4. Import quality, trustworthy. No formalities and higher cost
performance.
5. The first class of machine and make sure each of everything is
in good condition, must zero fault when leaving the factory, reduce
working pressure and cost from clients.
Technical Parameter | ||
Whole machine profile | Condition | Remanufactured |
Model | SG5332THB42 | |
S.N. | 211800308 | |
Brand | Putzmeister | |
Manufacture Year and Month | November of 2005 | |
Boom Length (M) | 42 | |
Chassis | VOLVO | |
Pumping system | Max.Theor.output (m3/h) | 140/100 |
Max.Theor.concrete output Pressure (MPa) | 7/12 | |
Max Concrete Pressure (bar) | 70 | |
Pumping frequency (min-1) | 24/14 | |
Hopper capacity (L) | 600 | |
Filling height (mm) | 1430 | |
Hydraulic system type | Open | |
Max Hydraulic Pressure (bar) | 360 | |
Valve | S Valve | |
Oil cylinder dia.x stroke (mm) | φ140×2000 | |
Concrete cylinder dia.x stroke (mm) | φ230×2000 | |
Hydraulic oil cooling | Air cooling | |
Placing boom | Max.aggregate dimension (mm) | 40 |
Structure type | M42-4R | |
Placing depth (m) | 42 | |
horizontal length | 38 | |
vertical height | 42 | |
Slewing angle | ±365° | |
Boom section | 4 | |
Pipe diameter (mm) | 125 | |
Chassis and the whole machine | End hose length (mm) | 4000 |
Cab type | FM 9-12 | |
Approval number | 107Fh | |
Engine type | D12 | |
Serial number | 7102091 | |
Process colour | D 1103-2 | |
Drive mode | 8X4 | |
Prod.type | FM 84R B | |
VIN NO. | YV2JN50G85A608730* | |
Maximum engine power | 279KW | |
Maximum speed | 80 km/h | |
Maximum RPM | 1685 rpm | |
Weight of chassis and cab (kg) | 10040 | |
Total weight (kg) | 32960 | |
Overall dimensions (mm) | 12981x2490x3867 | |
Other | No. of Seats | 2 |
Lubrication mode | Energy-saving automatic lubrication | |
Control mode | Manual+ Remote control | |
Water tank volume (L) | 600 | |
Pipe cleaning mode | Washing and dry cleaning |
Only with the stable lower plate is the pump truck safe. The
arm-frame pump truck supporting leg should be paid much attention.
Just like kung fu, if your "lower plate" is not strong enough, you
can easily be pushed down. Whether Putzmeister second hand pump trucks' legs can firmly "plunge" on the ground, is the
priority of the safe operation of the arm gantry pump truck.
1. Protect yourself and others from dangerous areas
When opening or closing the leg of the gantry Putzmeister stationary concrete pump, the rotation range is a dangerous area. People may be hurt in the
range. When carrying out this operation, you should be careful of
yourself and the people nearby.
2. To strengthen of the overlapping location is great. The
supporting legs should be extended in place.
The legs of the arm pump truck all have fixed strengthening
positions. Only when the legs are opened and extended in place can
these strengthening positions give full play to the strength.
Otherwise, the supporting legs will be in danger of breaking. Pay
attention to the arrows on the legs and ears as you extend them.
3. Communicate with construction personnel in advance and don't
"step on empty"
The gantry pump truck must be supported on a solid ground. If the
maximum pressure of the supporting leg is greater than the
allowable pressure on the ground, the supporting plate or auxiliary
square shall be used to increase the supporting surface area. In
addition, communicate with the person familiar with the
construction site before supporting the leg, and make sure the leg
is not above the sewer.
4. Keep a safe distance to prevent ground collapse
Adequate safety distance should be set aside to prevent ground
collapse when support is near a pit or ramp.
5. The arm pump truck must be leveled and must not exceed 3 degrees
After the support is completed, make sure that the maximum
horizontal deflection of the gantry Putzmeister truck mounted concrete pump is no more than 3 degrees. Generally speaking, the direction of the
extension of the arm frame will be raised higher during the
construction process, leaving a surplus for the subsidence after
the extension of the arm frame. Currently, the arm mounted pump
truck is usually equipped with an electronic level and alarm
device. Once the arm mounted pump truck tilts too high, the alarm
will sound to remind the operator. Before extending the armrest,
make sure the legs are properly attached.
6. Remote control ensures the safety. Do not be too high from the
ground
Upon confirmation of all the leg under the condition of reliable
and efficient, make confirmation on the leg safety with the first
and second boom. The specific approach is to stretch one arm frame,
making the open Angle at 90 degrees. Then let two booms in one
meter off the ground. Move one arm up and down in the position of
four legs, check whether the corresponding arm bracket and diagonal
arm bracket are safe.
7. If water enters under the leg, the arm shall be returned for
safety
In case of the occurrence of rain water, oil cylinder leakage of
supporting legs and factors reducing the stability of supporting
legs, the arm shelf should be closed immediately. After the problem
is eliminated, the supporting legs should be put up again according
to the requirements.
In addition, when supporting the arm pump truck, it is better to
keep the tire off the ground by 5 cm or so. Otherwise, the swing of
the s swing tube of the arm pump vehicle and the shaking of the
vehicle caused by the impact of pressure in the tube will damage
the vehicle driving mechanism.