145kV Tested High Voltage AC Circuit Breaker SF6 Type With 3 Pole

Country/Region china
City & Province ningbo zhejiang
Categories Other Roadway Products
InquireNow

Product Details

145kV Tested High Voltage AC Circuit Breaker SF6 Type With 3 Pole

 

Overview

LW36-145/T3150-40 HV AC SF6 circuit breaker is an outdoor product.It can also be used as a connection circuit breaker.

1. Altitudes :  2000m (product designs for 3000m are available)

2. Environment temperautere: -30ºC~+40ºC

3. Pollution grade: Class iV 

Parameters

Table 1

 

No.ItemsUnitParameters
1System nominal voltagekV145
2Rated voltagekV132
3Rated frequencyHz50
4Rated currentA3150
5Rated short-circuit breaking currentkA31.540
6Rated short-circuit making currentkA80100
7Rated short time withstand current/timekA/s31.5/440/3
8Rated peak withstand currentkA80100
9First-pole-to-clear factor 1.5
10Lightning impulse withstand voltagekV650
111min power frequency withstand voltagekV275
12Creepage distance fracture/to earthcm/kV250/250
13Rated operation order O-0.3s-CO
-180s-CO
14Making timems≤110
15Breaking timems≤65
16Closing-opening timems≤100
17Closing non-simultaneityms≤5
18Opening non-simultaneityms≤3
19Fracture no of per polepiece1
20Mechanical endurancetime6000
21SF6 gas pressure Rated value
(20ºC) Alarm value
The lowest function pressure
MPa
MPa
MPa
0.55
0.50
0.45
0.60
0.55
0.50
 

 

22SF6 moisture contentppm(V/V)≤150
23SF6 yearly air leakage percentage ≤1%
24Per set circuit-breaker SF6 gas charging weightkg911
25Gross weight of per set circuit-breakerkg2200
26Sub-static pull on wiring longitudinal
terminal of circuit-breaker horizontal
vertical
N
N
N
1250
750
1000
27Voltage of auxiliary circuitVAC220
28Opening-closing coil rated voltage
rated current
V
A
DC220 or DC110
1.29
29Energy Storage motor rated voltage
rated power
V
W
AC220 or DC 220
700
30Energy storage times≤15
31Heater voltage
power
V
W
AC220
100
32Standards GB1984


3.2 Mechanical parameters of circuit breaker
Table 2

No.NameUnitParameters
1Contact travel of moving-contactmm38~42
2Main drive lever travel of mechanismmm113~118
3Distance between opening movable and static contactmm75~80

 

Hot Products

20KV Electrical Distribution Step Down Dry Type Electrical Transformers Basic Info. Model NO.: SG (H...
Insulating Non-encapsulated Environmental Cast Resin Dry Type Transformer Overview: Insulating Non...
35KV Transformer Station Resin Insulation Dry - Type Power Transformer Overview SCB series resin ...
35KV Transformer Station Resin Insulation Dry - Type Power Transformer Overview This product adopts ...
6 ~ 35 KV / 30 ~ 2500 KVA Resin Casting Dry Type Distribution Transformer ​ General: As the ...