Home Companies Ningbo Tianan (Group) Co.,Ltd.

Indoor Electric Cabinet Distribution Low Voltage And Mv Switchgear

Ningbo Tianan (Group) Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: 3/F, Building B7 , 999 Yangfan Road,High-tech Zone, Ningbo, China 315040

Contact name:Lian Huanhuan

Inquir Now

Ningbo Tianan (Group) Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Indoor Electric Cabinet Distribution Low Voltage And Mv Switchgear

Country/Region china
City & Province ningbo zhejiang
Categories Other Chargers
InquireNow

Product Details

Indoor Electric Cabinet Distribution Low Voltage And Mv Switchgear

Product Description:

This product is suitable for power distribution systems of power plants, oil and chemical industry, metallurgy industry and high-rise buildings, especially in some places where requires for high automation and connection to computers such as larger power plants and petrochemical industry. It adapts to 3-phase system with frequency 50 (60) Hz, rated voltage 380V (400), (600), rated current 4000A (Max), and is used for low voltage distribution equipment of power supply system, motor control center and reactive power compensation.

 

Features:

a. The main structure is made of shaped steel of type 8MF with two mounting holes

    (m=20mm, 100mm, and diameter=9.2mm). On both sides. It is flexible and convenient to assemble.

b. The function units are divided into three compartments: Function compartment, busbar compartment

    and cable compartment, each has independent function.

c. The horizontal busbars are arranged in parallel at the back of cubicle to strength their resistance

    to electric power, which is the basic measure to make main circuit have high intensity of short circuit.

d. The design of disconnected unit for cable makes it convenient for cable's use.

 

Reference specification:

Rated voltage of main circuit( V)400, 690
Rated insulation voltage( V)690, 1000
Rated frequency( Hz)50
Rated insulation voltage( V)660( 1000)
Rated current ( A)Horizontal busbar< =4000
Vertical busbar1000
Rated short time withstand current of busbar( kA/1s)80
Rated peak withstand current of busbar( kA/0.1s)176
Power frequency testing voltage (V/1min)Main circuit2500
Auxiliary circuit1760
Busbar3-phase and 4-wireA. B. C. PEN
3-phase and 5-wireA. B. C. PE. N
Protection degreeIP30. IP40
Dimensions2200x (600 800 1000)x600(800 1000)

 

Reference data for Breaker:

TypeTANW1-2000TANW1-3200TANW1-4000TANW1-6300
Frame rated current
Inm(A)
2000320040006300
Rated current In(A)630,800,
1000,1250,1600,2000
2000,2500,2900,32003200,3600,
4000
4000,5000,
6300
Rated insulation voltage Ui(V)1000
Rated operational voltage Ue(V)AC400,AC690
Rated limit short circuit breaking capacity Icu(kA)AC400V80100100120
AC690V50657585
Rated running short circuit breaking capacity Ics(kA)AC400V506580100
AC690V40656575
Rated short time withstand current 1cw,1sAC400V506565/8085/100
Rated impulse withstand current Uimp(V)8000
Dielectric property(V)3000

 

Hot Products

20KV Electrical Distribution Step Down Dry Type Electrical Transformers Basic Info. Model NO.: SG (H...
Insulating Non-encapsulated Environmental Cast Resin Dry Type Transformer Overview: Insulating Non...
35KV Transformer Station Resin Insulation Dry - Type Power Transformer Overview SCB series resin ...
35KV Transformer Station Resin Insulation Dry - Type Power Transformer Overview This product adopts ...
6 ~ 35 KV / 30 ~ 2500 KVA Resin Casting Dry Type Distribution Transformer ​ General: As the ...
30 ~ 2500 KVA Thin - Insulation Resin Cast Dry Type Power Transformer General: 10 KV grade SCB10, ...