Home Companies Ningbo Tianan (Group) Co.,Ltd.

Smart Grid Device And Systems Prefabriated Substation Electric Protector TA-D3000 Series

Ningbo Tianan (Group) Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: 3/F, Building B7 , 999 Yangfan Road,High-tech Zone, Ningbo, China 315040

Contact name:Lian Huanhuan

Inquir Now

Ningbo Tianan (Group) Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Smart Grid Device And Systems Prefabriated Substation Electric Protector TA-D3000 Series

Country/Region china
City & Province ningbo zhejiang
Categories Battery Chargers
InquireNow

Product Details

Overview

TA-D3000 Series Box Transformer Substation Intelligent Measuring and Monitoring Protection Device is widely used in 35KV and below box-type substation of different voltage classes, wind power plant, solar power station and other equipment’s complete measuring and monitoring protection device. It combines protection, measurement, communications functions, so as to achieve the high/middle/low transformer or line of measuring and monitoring protection function.

 

Feature

1. 4U standard aluminium classis, combination of plug-in structure, back swap classis, independent function module design, strong and weak electricity separated completely, strong anti-interference capacity, convenient on-site maintenance;

2. It is multi-CPU intelligent plug-in design, switch plug-in realize the real-time entirely self-test; it can detect each relay coil;

3. Contact between plug-ins based on CANBUS bus, reducing the connection between plug-in, realizing plug-in trouble real-time detection;

4. Dual 32-bit system, system redundancy ; protection produced using the Texas Instruments 32-bit floating point DSP processor, the program and data run on the chip; quickly and high reliability;

5. HMI, network communications and other management functions achieved by Philips 32 ARM MCU run fast, with large on-chip memory capacity and strong network interface capabilities;

6. 16 AD sampling, high accuracy; 48 points per cycle sampling, strong harmonic processing capability;

7. Protection modules use computer auxiliary graph interface design principles to facilitate the secondary development of products and functional modifications. Engineering design is flexible and fast;

8. Complete circuit breaker operating circuit with remote tripping and closing, pressure lockout, spring un-stored energy latching switch functions;

9. Flexibility to choose monochrome or large color LCD, Chinese interface menu; flexibility to choose dual Ethernet, dual CANBUS, dual 485;

10. It can save at least 500 incident reports and run reports recently;

11. Human management module use real-time multitasking operating system, tasks such as interface and network have good real-time performance;

12. Able to store 10 sets of protection settings, dual setting area combination of self-test and mutual inspection, safe and convenient setting switch;

13. Standard communication protocol based power industry DL / T667-1999 (IEC 60870-5-103) to facilitate network communication with the computer monitor or the protection manager.

 

Parameter

Device functionFunctional description

TA-D

3010

TA-D

3011

TA-D

3020

TA-D

3021

TA-D

3001

TelemeteringThree-phase current, three-phase voltage, frequency, power factor, active power, reactive power, active energy, reactive energy. Straight flow input, 3-way, each optional: 4 ~ 20mA or heat resistance can be used to measure the ambient temperature, transformer oil and the like.   
Telemetering extension6-channel current, 6-channel voltage, used in the photovoltaic double transformer monitoring. Direct flow input, 2-way 4 ~ 20mA or heat resistance.   
Remote signaling20-way switch output measurement, AC / DC220V external active open into, 1-6 way switch output fixed non power protection signal 
Remote control4-channnels switch output 
ProtectionLight gas, heavy gas, transformer high temperature, transformer ultra-high temperature, transformer oil level low, SF6 exception, three-stop current protection, zero-sequence current protection, over voltage protection, low voltage protection. 
Error recordingRecord failure information and operational information recently occurred 25 times 
An electric portOptionalOptional  
Two optical ports, single mode, multimode optional   
RS485 series port ,1 RS485
Display panel

 

Hot Products

20KV Electrical Distribution Step Down Dry Type Electrical Transformers Basic Info. Model NO.: SG (H...
Insulating Non-encapsulated Environmental Cast Resin Dry Type Transformer Overview: Insulating Non...
35KV Transformer Station Resin Insulation Dry - Type Power Transformer Overview SCB series resin ...
35KV Transformer Station Resin Insulation Dry - Type Power Transformer Overview This product adopts ...
6 ~ 35 KV / 30 ~ 2500 KVA Resin Casting Dry Type Distribution Transformer ​ General: As the ...
30 ~ 2500 KVA Thin - Insulation Resin Cast Dry Type Power Transformer General: 10 KV grade SCB10, ...