INAB706C White PFE Particle Electrostatic Charge device Filtration Efficiency Tester 2.83L/min ±5%

Country/Region china
City & Province hangzhou zhejiang
Categories Analyzers
InquireNow

Product Details

INAB706C

Particle filtration efficiency tester(PFE)

 

INAB706C PFE Particle 100cm² Filtration Efficiency Tester

Product overview】: 

Particle filtration efficiency tester,suitable to test the filter material efficiency of 45-99.9% grade,test the filter according to international standard.The test bench is designed to be compact, lightweight, and during the test run, only suitable power and compressed air (no water, no oil) are needed. It is suitable for use in laboratory, factory, etc.

Test philosophy】:

The test sample is fixed on the fixture, and the test air volume corresponds to the required filtration speed.The aerosol produced by the aerosol generator is adjusted, then electrostatic neutralization (PSL), and then mixed with the filtered test air evenly, and then entered the test area through the filter material.In addition, it is necessary to measure the resistance of the filter material during the test and manually adjust the control flow.The product conforms to jjf1190-2008.

Reference standard】:

GB/T 32610-2016 Technical specifications for daily protective masks

GB 2626-2006 Respirator - self - imbibition filter respirator against particulate matter

 

GB19082-2009Technical requirements for disposable protective clothing for medical use
GB19083-2010Technical requirements for medical protective masks
YY0969-2013Disposable surgical mask

 

YY 0469-2011 Medical surgical masks

ISO-29463 Use hepa filters and filtration media to remove particulate matter from the air

Particle filtration efficiency tester【Constituent part】:

1. Aerosol generator

It is mainly used for the test of high concentration aerosol,PSL standard particles of 0.3um are used, and the particle size range of the main particles emitted is ≥0.3um, accounting for more than 70% of the total, which can continuously and stably produce aerosols. Upstream of the filter material, the test particles are provided.

2. Particle counter

It is mainly used to monitor the concentration of upstream and downstream particles of the measured filter material and obtain the efficiency of the measured filter material.

3.Differential pressure transducer

It is mainly used to test the pressure difference (or resistance) of the measured filter material under a certain test flow rate.

4.Stainless Steel Clamps

Mainly used for the pressure and sealing of the measured filter material.

5.Air pump

Mainly used for the test flow through the filter material, stable flow, green energy saving, small vibration noise.

6.Electrical control and software

Circuit control and operation of equipment, calculation and data processing of software, stability judgment of upstream concentration, operation control, parameter setting.

 

 

 

Particle filtration efficiency tester【Functional description】:

A. Filtration efficiency test and airflow resistance:

1. The whole test equipment adopts negative pressure system.

2. Air and aerosols enter through the test chamber and flow through the mask according to the standard

3. Two particle counters are used to detect the concentration of upstream and downstream and calculate the filtration efficiency. The pressure difference between upper and lower parts of the mask was detected by the pressure difference meter.

4. The rated flow rate is achieved by pumping.

5. Produce standard aerosol materials by aerosol generator.

6. Through the PLC and the display screen to carry out the operation of the equipment and the efficiency of the calculation of resistance.

 

 

 

 

 

 

 

 

 

 

 

 

Technical parameters】:

 

Test efficiency range45%-99.9%@≥ 0.3μ m
Test area100cm²
Test differential pressure range0-50pa± 1% , 50-500pa± 1.5%
Test flow of measured filter material25-100L/min±2.5%(adjustable)
Test aerosol typesPSL
Counter sampling flow2.83L/min ±5%
Particle size display@≥0.3um
Counter laser sourceLaser diode
Air pumpContinuous working stability
Data memory capacity1∽ 1000 sets of measurement data, can be exported
Screen displayColor 7-inch touch screen
Printing methodBuilt-in thermal printer
Power supplyAC 220V/50Hz
Power1kw
Data export interfaceUSB

 

Environment

Operating environment: 0∽ 40℃ Relative humidity: 10∽ 70%
Storage environment: 0℃∽ 45℃Relative humidity: 0∽ 70%

 

Standard accessories

Thermosensitive printing paper, hose (Outer diameter 6mm and 15mm), operating instruction, test report, qualification certificate
Overall dimensionsL 1000X W 760X H 1750(mm)
MaterialShell steel coating, test unit SUS304 stainless steel
weight150Kg
Accessories:
PSL Aerosol generator
Electrostatic neutralizer
Diluter

 

 

 

 

Hot Products

JXPM-F003 48w Filter Tester For Melt Blown Fabric Product overview Compared with the traditional ...
INCW30G 30g 0.001g 120m Per Min Check Weigher Machine The high-precision weighing scale developed ...
INCW-100 Biscuit overweight elimination separator on line Check weigher 100g 0.01g INCW100 100G 0...
Automatic Photometer 100cm Filtration Efficiency Tester 【Scope of application】 :It is used to ...
Automatic Filter Material 0.3um Electrical Test Bench Equipment The automatic filter material test ...
Small Bag 800g 100w Check Weigher Machine Technical parameters: Max capacity:800g Min weight: 2g ...