Home Companies Innovation Electronic Co.,Ltd

PLASMA CLEAN-05 Flexible Operation Antivibration AC220V (±20%) Thermal Bubble Tij Inkjet Printer 25-30kHz

Innovation Electronic Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: #201,Shunda Road, Yuhang Economic Area, Hangzhou,China

Contact name:TINA LIU

Inquir Now

Innovation Electronic Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

PLASMA CLEAN-05 Flexible Operation Antivibration AC220V (±20%) Thermal Bubble Tij Inkjet Printer 25-30kHz

Country/Region china
City & Province hangzhou zhejiang
Categories Used Measuring & Analysing Instruments
InquireNow

Product Details

Antivibration Designed TIJ Printer , Flexible Operation Thermal Inkjet Printer Input voltage AC220V (±20%)

 

Antivibration Designed TIJ Printer , Flexible Operation Thermal Inkjet Printer Input voltage AC220V (±20%)

  • Low temperature plasma surface treatment technology

The particle energy is about several to tens of MeV in low temperature plasma, the energy greater than the polymer materials combination bond energy (several to tens of EV), can break chemical bonds in organic molecules and form new bonds; but the energy is much lower than the high-energy radioactive energy, involving only the material surface, does not affect the properties of the matrix. 

 

1. Plasma nozzle 2. Voltmeter

3. Ammeter 4. Pause button

5. Start button 6. Barometer

7. Alarm buzzer 8. Panel power switch

9. Gas pressure control knob 10. Plasma nozzle and cable

11. Air source input 12. Plasma output control

13. 220Vac power supply input 14. Enclosure ground

15. Oil & water separator 16. Cooling fan

 

2. Installation

2.1 Nozzle installation

2.1.1 Install the nozzle on the mechanical arm or an appropriate position; fix properly, to keep the high-voltage cables, ground cable and gas tubes on the nozzle away from strong pulls, frictions, scrapes and piercing.

2.1.2 Adjust the distance between the nozzle and workpiece to be processed to 3.5mm~8mm .

2.1.3 The purple flame on the nozzle is a high voltage arc, do not touch by hand to avoid electric shock. The yellow or light yellow flame area is the safe area.

 

2.1.4 The people who are not the after-sales staff or professional technicians shall not randomly change or replace the nozzle.

 

2.2 The installation of main machine

2.2.1 When it is in the operation, the main machine’s fan and exhaust window shall not be obstructed by anything.

2.2.2 Place the main machine on a flat ground, and keep it well ventilated.

2.2.3 The 4 sides of the main machine shall not be close to a large area of iron, please keep them above 10cm away from the iron, otherwise it will lead to the increased power consumption and temperature rise due to eddy current effect;

 

2.2.4 The input air source shall be connected to “GAS” on the back, please use a dry air source to guarantee a good treatment quality and a long service life for the nozzle.

 

2.3 AC220V power supply connection

2.3.1 Please use the cables attached for the machine, or choose the cables with the sizes over 1.5mm^2, connect the AC220V power supply to the power input of the machine. The connection has no polarity, but it shall not be mistaken as the ground.

 

2.3.2 The power plug of the main machine shall be reliably grounded, or the enclosure of the main machine shall be reliably grounded, each time before you start the operation, you shall check whether it is well grounded. The machine is high-voltage equipment; if it is not reliably grounded, do not turn on the power supply to start randomly, as there will be an electric shock!

2.3.3 The screws on the connection platform shall be tightened firmly, otherwise it will work intermittently or the platform will be burnt by overheat.

 

4. Operation guide

1. Connect the dry air source to “GAS IN” end.

2. Adjust “gas pressure knob”, to make the reading of “barometer” to 0.2Mpa (2.0KG), attention: too high pressure or too low pressure will lead to low treatment quality.

3. Toggle “220Vac breaker” up to “ON”, check whether the cooling fan works normally, and check whether there is any reading on the voltmeter and the ammeter.

4. Press “start button”, the nozzle will start and the machine will be in the operation.

5. When it is in the normal operation, the reading on the voltmeter and the ammeter on the panel will be stable, the fluctuations within ±3V and ±0.05A are normal.

 

6. When it stops, press stop button”, and then toggle “AC220V power supply switch down to “OFF”.

7. When you use “plasma output control”, please use the mechanical controller switch, or the electrical controller switch. When you use the electrical controller switch, you shall use the relay (and the similar electrical insulation) electrical switch.

 

5. Main technical parameters

1. Input voltage: AC220V (±20%)

2. Input voltage fluctuation range: ±3V

3. Input current: 2.4A-3.1A

4. Capacity: 600-1000 VA

5. Treatment width: 50mm

6. Frequency: 25-30kHz

7. Air source pressure: 0.10Mpa~0.20Mpa (1.0Kg/cm²~2.0Kg/cm²)

8. Main machine dimensions: 560mm*253mm*460mm

9. Weight: 30kg

10. Relative humidity: <93% (No dew)

11. Storage environment temperature:-25℃~+55℃

 

Hot Products

JXPM-F003 48w Filter Tester For Melt Blown Fabric Product overview Compared with the traditional ...
INCW30G 30g 0.001g 120m Per Min Check Weigher Machine The high-precision weighing scale developed ...
INCW-100 Biscuit overweight elimination separator on line Check weigher 100g 0.01g INCW100 100G 0...
Automatic Photometer 100cm Filtration Efficiency Tester 【Scope of application】 :It is used to ...
Automatic Filter Material 0.3um Electrical Test Bench Equipment The automatic filter material test ...
Small Bag 800g 100w Check Weigher Machine Technical parameters: Max capacity:800g Min weight: 2g ...