KOMEG Technology Ind Co., Limited |
|
CE Standard With Thermal Shock Test Chamber for Automobile Parts Reliability Test And PCB Test
1. Thermal Shock Chambers :
Thermal shock chamber is metal, plastic, rubber, electronics and
other industries necessary testing equipment. For the continuous
exposure to extremely high temperature, very low temperature
environment, instant exposure of the material structure or
composite material tolerance, can be detected in the shortest
possible time due to thermal expansion and contraction caused by
chemical or physical damage.
The KOMEG thermal shock chamber meets today's environmental stress
screening requirements and is proven in installations around the
world. Our hot and cold direct transfer method is an economical way
to achieve ESS or thermal shocks for rapid component temperature
changes.
2. 3-Zone Thermal Shock Chambers Application:
Such chambers heretofore known include one comprising a test area
for the test sample, a high-temperature air conditioning unit
having gas outlet and intake adapted to communicate with the test
area, an outside air supplying unit having air outlet and inlet
adapted to communicate with the test area, and a low-temperature
air conditioning unit having gas outlet and intake adapted to
communicate with the test area.
The thermal shock chamber of this type is provided with three
dampers, i.e., one for opening or closing the gas outlet and intake
of the high-temperature air conditioning unit, another for the air
outlet and inlet of the outside air supplying unit, and another for
the gas outlet and intake of the low-temperature air conditioning
unit.
3. Specification
(1) KTS-A Series
Model |
| ||||||||
72A | 100A | 150A | 200A | 252A | 300A | 480A | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
Low Temp Chamber | -55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC | ||||||||
Test Chamber | -40ºC~+150ºC | ||||||||
High Temp Chamber | +60ºC~+200ºC ,Within 20 min, Pre-heating time | ||||||||
Transition time | ≤15S | ||||||||
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
≤ 5 min | |||||||||
Ambient Temp. | +5ºC~+35ºC | ||||||||
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(2) KTS-B Series
Model |
| ||||||||
72B | 100B | 150B | 200B | 252B | 300B | 480B | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
Test weight(KG) | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
Low Temp. chamber | -70ºC~-10ºC ,Pre cooling time: +20ºC~-70ºC ,≤ 60 min | ||||||||
Test. Chamber | -55ºC~+150ºC | ||||||||
High Temp. chamber temperature | +60ºC~+200ºC,Preheating time: ≤20 min | ||||||||
Transition time | ≤15S | ||||||||
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
≤ 5 min | |||||||||
Ambient Temp. | +5ºC~+35ºC | ||||||||
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(3) KTS-D Series
Model |
| ||||||||
72D | 100D | 150D | 200D | 252D | 300D | 480D | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
Low Temp Chamber | -80ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-80ºC | ||||||||
Test Chamber | -65ºC~+150ºC | ||||||||
High Temp Chamber | +60ºC~+200ºC ,Within 20 min, Pre-heating time | ||||||||
Transition time | ≤15S | ||||||||
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
≤ 5 min | |||||||||
Ambient Temp. | +5ºC~+35ºC | ||||||||
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
4. Features of Different Cooling Mode for thermal shock chambers:
Since the cold chamber need huge cooling capacity for shocking, the chamber’s cooling mode is often designed as air-cooled or water-cooled.
Air-cooled type need installation environment:
The room must be equipped with exhauster and air conditioner to
make sure heat dissipation timely.
It’s applied to small power products and cool areas.
Water-cooled type need installation conditions:
The customer must prepare water pipe and water tower (located
outside) accordingly.
The water must be pure, or it will block the pipes and result in
some maintenance trouble with time going.
It’s often applied to large system with the features of better heat
dissipation, longer service time, low noise but slightly higher
price if count the fee of water tower and water pipes.
:
Packing Details:
We use PP Film wrapping the test chamber to protect the test chamber from moisture or being scratched first, then use strong plywood case for easy load and transport, and to keep the chambers from potential crash or impact.