KOMEG Technology Ind Co., Limited |
|
Electronic Salt Spray Testing Machine Simulation Test Chamber
KOMEG offers the newest and most modern salt fog testing chambers
for your testing requirements. KOMEG salt spray test chambers are
offered in 60 Liter, 270 Liter, 800 Liter and 960 Liter models and
are cost effective solutions to acceleratedcorrosion testing of
samples in salt fog. Models have an uncomplicated design that has
optimized the openarea to maximize the number of test coupons while
providing headroom for testing large and bulky objects.
Specifications
Specifications (Note: We reserve the right to change specifications without prior notice) | ||||
Model | HL-160-NS | HL-120-BS | HL-90-BS | HL-60-SS |
Interior dimensions(W*H*D)mm | 1600 X 500 X 1000 | 1200 X 500 X 800 | 900 X 500 X 600 | 600 X 400 X 450 |
Exterior dimensions(W*H*D)mm | 2240 X 1500 X 1600 | 1410 X 1280 X 880 | 1460 X 1280 X 910 | 1130 X 1070 X 630 |
Testspace Volume(L) | 800 | 480 | 270 | 108 |
Salt Water Tank Volume (L) | 60 | 40 | 25 | 15 |
Heater | 15KW+1KW | 11KW+1KW | 7KW+0.75KW | 3KW+0.75KW |
Air compressor | 2HP | 2HP | 1/2HP | 1/2HP |
Temp. range (Testing barrel) | 35±1℃~50±1℃ | |||
Temp. range (Pressure barrel) | 47±1℃~63±1℃ | |||
Test applicable | NSS, ACSS,CASS,CORK | |||
Pressed Air Pressure | 1.00±0.01kgf/cm² | |||
Spray Amount | 1.0~2.0ml/80cm²/h(Collect at least 16 hours, take the average) | |||
Ambient Relative Humidity | More than 85%R.H. | |||
PH Value | 6.5~7.2 3.0~3.2 | |||
Spraying Manner | Programmable Spraying | |||
Power | AC220V 1Φ 50Hz |
Advantages
Salt Water Spray Test Chamber's Features
A. The whole part of the device is made of P.V.C. Sheet and the
inside of the device is reinforced by using a special lining
material. Hence, it is sturdily made and will not transform
forever.
B. The test chamber is heated from five directions in order to
ensure the temperature difference in the chamber may be kept within
(± 1℃).
C. Spray nozzle: The nozzle is specially made to enable it to suck
up the salt water and then spray it out in the shape of mist with
considerable high speed. When it falls on the surface of the item
being tested, the difference of fallen mist may be controlled
within ± 0.3ml / 80 cm2h.
D. HUNTER PRINCIPLE is used to make the saturated air hot and moist
and to keep the humidity in the test chamber required for test.
E. Temperature is the pre-requisite condition that with have direct
impact on corrosion rate. We use P.I.D. temperature control unit to
limit the temperature difference within the range of ± 0.5℃.
F. A warning device is used to indicate the low level of the test
fluid, when the fluid is only enough for being sprayed for five
hours, a buzzer will remind the user to replenish the liquid to
ensure continuous spray test.
G. Use full automatic detecting system, test stopped automatic, and
lighting display when trouble.
Combined Cycle Tester System Diagram
Salt Spray Test Chamber System Diagram
Salt Spray Testing working Principle
Standards implemented and met:
1) GB/T 2423.17-1993 salt spray test
2) GB/T 2423.18-2000 salt spray test
3) GB/T 10125-1997 salt spray test
4) ASTM.B117-97 salt spray test
5) JIS H8502 salt spray test
6) IEC68-2-11 salt spray test
7) IEC68-2-52 1996 salt spray test
8) GB.10587-89 salt spray test
9) CNS.4158 salt spray test
10) CNS.4159 CASS Copper accelerated acid salt spray test
11) GB/T 12967.3-91 CASS Copper accelerated acid salt spray test