HANGZHOU HENGQING TECHNOLOGY CO.,LTD |
LC3000SP Binary Semi-preparative HPLC, 0.01-50ml/min,0.1-10mg
Product Description
Preparative method confirmation and optimization
the system can use the preparative method which we can get from the analyti-cal HPLC system to confirm and optimize the preparative method.
Recommendation : LC3000SP semi-preparative HPLC system.
LC3000S semi-preparative high performance liquid chromatography
system can produce purifications from mg to gram scale.
Applications:natural extracts,synthetic mixtures,chiral compounds,etc.
The system comprises as follows:
No. | Description | Quantity |
1 | P3000 HPLC pump, 50ml pump head (stainless steel) | 2 |
2 | UV3000 UV-VIS Detector with preparative flow cell | 1 |
3 | Rheodyne 7725i manual injection valve OR A1359 manual injection valve(sample loop can be customized) | 1 |
4 | CXTH-3000 Chromatography Workstation | 1 |
5 | Preparative column,Column size can be customized(ID 10mm-30mm)*3 | 1 |
6 | Isocratic Starter-kit, semi-preparative | 1 |
7 | Solvent tray | 1 |
8 | Dynamic mixing chamber,semi-pieparative | 1 |
9 | Accessories required(recommended)* |
|
Note:
* When the customers use the HPLC system for the fist time, we suggest that solvent filter, vacuum pump, ultrasonic cleaner, AC regulated power supply should be equipped.
Preparation of the sample mass range
You may need to select the type of the inner diameter of the preparative column , this system the amount of sample can be prepared substantially as 0.1mg to 100mg .
P3000 Semi-Preparative High Pressure Pump Specification
P3000 HPLC pump is a new generation of pumps that use CPLD technology and be controlled by microprocessor. It presents us high precision and accuracy based on fully digital frequency generation system, advanced motor driver system and kindly user‘s interface. The design of the pump shares experiences from the most advanced pumps in the world. Our independent concept is that we can give longer guarantee to customers for trouble free. The flow rate calibration can be processed at anytime by the firmware that ensures the user to obtain better analysis reproducibility and higher measurement accuracy. P3000 HPLC pumps support HPG, customers can use the HPG mode by introducing additional P3000 pump up to quaternary.
SPECIFICATIONS
Hydraulic system | Dual piston in series pump, main & auxiliary |
Pump head | 10ml stainless steel /PEEK analytical 50 ml stainless steel /PEEK semi-preparative |
Maximum working pressure | 10ml pump head 42Mpa for stainless steel /30Mpa for PEEK 50ml pump head 30Mpa for stainless steel /20Mpa for PEEK |
Flow Range | 10ml pump head 0.001-9.999ml/min 50ml pump head 0.001-49.99ml/min |
Flow rate accuracy | ±0.5% measurement at 1ml/min |
Flow rate precision | RSD≤0.1% measurement at 1ml/min |
Display | 320 X 240 blue background color |
Protection | Adjustive Pmax & Pmin, the pump stop automatically when the pressure higher than Pmax or lower than Pmin for 2 minutes, meanwhile the data will be automatically saved |
System connection | 1/16”capillaries |
Control | Stand-alone mode by front keypad HPG Mode: one pump work as master, others work as slave CXTH control software(e.g. CXTH3000,Clarity etc. ) |
Communications | RS-232 |
Power supply | AC220V±10%,50Hz,400W |
Dimensions and weight | 410 X 270 X 180mm(LX W X H) 14Kg |
Ordering Details:
No. | Description | Quantity |
1 | P3000 HPLC pump with 10ml pump head (stainless steel) | 1 |
2 | P3000 HPLC pump with 10ml pump head PEEK | 1 |
3 | P3000 HPLC pump with 50ml pump head (stainless steel) | 1 |
4 | P300 HPLC pump with 50ml pump head PEEK | 1 |
UV3000 UV/VIS Detector Specification
UV3000 is completely digital designed. It is also a UV-VIS detector and can be controlled by PC. It is widely used in biology, environment, pesticide, pharmacy and chemistry etc. The wavelength of the detector can be selected between 190 and 700nm and can be changed during measurement.
SPECIFICATION
Wavelength Range | 190-700nm |
Light Source | Deuterium lamp (standard) Tungsten-Halogen lamp (optional) |
Wavelength accuracy | <±1nm |
Wavelength precision | 0.2nm |
Wavelength Scanning | Stop-flow scanning mode, the start, the end and the step length of the scan can be set in program. |
Detection Range | 0-2AU |
Baseline Noise | 1 X 10-5 AU Measuring method: Dynamic, Flow rate 1ml/min methanol/water=80/20, Wavelength 254nm |
Baseline Drift | 4 X 10-4 AU/h Measuring method: Dynamic, Flow rate 1ml/min methanol/water=80/20, Wavelength 254nm |
Time Constant | 0.1/0.2/0.5/1/2/5/10s |
Analog Output | ±0.1V ±1.0V ±10V |
Integrator Output | 16grades adjustable |
Auto zero | Full scale range |
Control | Stand-alone mode by front keypad CXTH control software(e.g. CXTH3000,Clarity etc. ) |
Communications | RS-232 |
Display | 320 X 240 latticed LCD Screen display, adjustable blue background light |
Power | 220V±10%,50Hz,60W |
Dimensions and Weight | 410 X 270 X 180mm (L X W X H) 10kg |
GLP Support | Detailed reports such as lamp operation time, number of lamp ignitions and further service information. |
Ordering Details:
No. | Description | Quantity |
1 | UV-VIS Detector UV3000 | 1 |
2 | Tungsten-Halogen lamp with base | 1 |
3 | Deuterium lamp with base | 1 |
4 | Semi-Preparative Flow Cell | 1 |
Application Range
Ø Natural plant extract
Ø Synthetic medicine
Ø Protein and peptide separation
Our typical customers
1.Zhejiang Medicine Co.Ltd.Xinchang Pharmaceutical Factory(XINCHANG PHARM.)
http://www.xcpharma.com/english/about.asp
2. Zhejiang Hisun Pharmaceutical Co. Ltd
http://www.hisunpharm.com/English/index.html
3. Zhejiang Huahai Pharmaceuticals Co., Ltd.
4. uXi AppTec (NYSE: WX)
About sales
If you need more technical support , please contact our Sales Manager , we have strong technical engineers can provide you with a detailed drug purification solutions .