Stainless steel Low Temperature Air to Water heat pumps EVI, Scroll Compressor Heat Pump

 

AW10/L - DNNNS

LOW TEMPERATURE AIR TO WATER HEAT PUMP

AW10/L-DNNNS

Heat output/Power consumption at 7/35℃

kW

11.40/2.70

Heat output/Power consumption at 7/45℃

kW

12.10/3.41

Heat output/Power consumption at 7/55℃

kW

12.18/4.19

Heat output/Power consumption at 2/35℃

kW

10.30/2.70

Heat output/Power consumption at 2/45℃

kW

11.63/3.37

Heat output/Power consumption at -7/35℃

kW

9.78/3.04

Heat output/Power consumption at -7/45℃

kW

9.66/3.58

Heat output/Power consumption at -10/35℃

kW

8.75/3.04

Heat output/Power consumption at -10/45℃

kW

8.57/3.62

Heat output/Power consumption at -15/35℃

kW

7.82/3.09

Heat output/Power consumption at -15/45℃

kW

7.73/3.62

Starting current 

A

53

Power

 

380-415V/3PH/50Hz

Compressor

 

HITACHI scroll

Condenser

 

Brazed plate heat exchanger

Nominal flow heating medium

l/s

0.55

Internal pressure drop at nominal flow

kPa

16

Air flow

m3/h

5000

Nominal output fan

W

300

Max outgoing heating medium temperature

55

Dimensions(HxWxD)

mm

1075X1105X505

Pipe connector

 

DN32

Weight

kg

185

The above data is tested by EN14511

 


More Detail:

HISEER low temperature air source heat pump AW10/L-DNNNS, adopt Hitachi EVI compressor, can be used at -20 degree outside temperature. The injection new technology make it possible that, even at -15 degree, the efficiency of the heat pump can reach 1.9. This is the ideal product to be used at the rather cold winter area.

 

EVI low temperature AW10/L-DNNNS, stainless steel (443) cabinet, 380V/3/50Hz, R410a, all the parts install into one cabinet, adopt the following world famous parts:

*Hitachi EVI compressor

*SWEP or GEA plate type heat exchanger

*Schneider A/C contactor

*Saginomiya low pressure switch

*Carle pressure sensor

*Honeywell R410a refrigeration

 

When the ambient temperature drops to below zero degree in winter, the normal air source heat pump can not run stably caused by the system low evaporated temperature, small gas absorption , small system gas flow and unstable superheat degree, etc . So that the air source heat pump’s heating output is low , the system runs unstably , even worse to cause the compressor damaged. Normal air source heat pump can not meet the heating requirement in the cold area in winter. So, the market for the heat pumps that can work under low ambient temp. is promising.

Hot Products

EVI Low temperature Scroll Compressor Heat Pump, Room Air Source Heat Pumps 2- 15KW HISEER low ...
Stainless steel Low Temperature Air to Water heat pumps EVI, Scroll Compressor Heat Pump AW10/L - ...
Energy Saving House Air to Water EVI Injection Air Source Heat Pumps, House Heat Pump 3KW Energy ...
Air to Water Electric R410a Low Temperature Air Source Heat Pumps, Residential Heat Pump Energy ...
7- 15KW Monobloc Air to Water Low Temperature, Home Heating Air Source Heat Pumps EVI HISEER low ...
R410a Low Ambient EVI Stainless Steel Air Source Air to Water Heat Pumps For Home EVI low temperatur...