Mobile Dental X Ray Machine / Portable X Ray Equipment With 0.1 MA Tube Current

City & Province shenzhen guangdong
InquireNow

Product Details

BLX - 8 Portable Dental X - ray Machine Wireless Digital Portable Dental Equipment

 

Technical Specifications:

 

Power ( V )24V 8000MA
Charger220V / 110V 50 HZ
Tube Voltage70 KV
Tube Current0.1 MA
Frequency30 KHz
Time of Exposure1 - 9 s
Radiation Leakage< 20 μ gy / h
Rated Power60 W
Weight2.2 KG
Relative Humidity< 80 %
Environmental Temperature 5 - 40 °C

 

Size:


1. Carton: Length 51cm, height 33cm, width 31cm.
2. Aluminum case: Length 42cm, height 22cm, width 27cm. Gross weight: 6 kg

3. Net weight: 2.2 kg

 

The Composition and Use of the Equipment:

 

The machine is made up of two parts: the main unit and the ball head. The main unit includes the power supply,central data processing unit,and the part to shock,enlarge,and feedback. The ball head is made up by components with functions of controlling pressure and frequency and ball tube,vacuum sealed part, etc. The shell is from an injection mold with lead sealing protection.

The machine is mainly used in dental clinics,to check out before treatment,and to be used for comparison and confirmation during and after treatment. It is an indispensable piece of equipment for daily work within a clinic. Some examples of its use include checking tissue structure,the depth of the root,the degree of inflammation,and for the inner inspection of broken teeth.

While using a small amount of radiation there is no need for protection. Hospitals have purchased this machine to take films of fingers and toes by the side of a patient's bed

 

Operation of the Main Unit:

  1. Upon receiving,open the box and check the product for possible damage during shipping.
  2. Make sure the fittings on the encasement list are packaged within the box.
  3. Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw; Install the blue ray tube to the foreside of the ball head,then tighten it.
  4. After the Main Unit and ball head are perfectly fit together,plug in the international standard electrical source,grounding is strongly recommended.
  5. Turn on the Power;the pilot lamp will be light up.During this time,the digital tube of the main unit will show the fore setting time. Now the equipment is in standby mode.
  6. Setting the time (Skip to next step if unneeded) Use the "SET","+",and" -" buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
  7. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
  8. Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.
  9. After positioning,use the ON/OFF on the main Unit,the remote controller,or the button on the touch head tube to take pictures. The three methods have the same effect. (Notice: gently press 0.5 sec to turn it on)
  10. After exposure to the tube,press the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray,so the dental films can be used again).
  11. Repeat step 6 to reset the picturing time.To repeat the picturing process,please repeat steps 7 to 9.
  12. Turn the power of the main unit off when the work is finished,press POWER, making sure the pilot lamp is off.Don't keep the main unit long in standby mode.

Reference of the Angles:

 

ToothUpperLower
1 - 242- 15
345- 18
4 - 530- 10
6 - 828- 5

 

 

ToothAdultChild
Central & Lateral2.5 - 3.252 - 2.7 
Cuspid & 1 Biscuspid3.2 - 42.7 - 3.5
Upper 5 , 63.5 - 43 - 3.5
Upper 7 , 87.5 - 87- 7.5
Lower 5 , 64 - 4.53.5 - 4
Lower 7 , 84 - 4.53.5 - 4

 

Notice:

 

1. For your safety, do not open the unit. Only professional personnel can inspect and repair the vacuum components and high-voltage parts of the X-ray machine.


2. Tubehead equipped with perfect radiation-shield protection except the radial mouth. The test shows the radial index is zero. Safety is guaranteed.

 

Hot Products

Dental Russian type metal matrices assorted kit stainless steel matrices 1. Made of high quality ...
green silicone Dental Add-on Fixing Wedges Dental Matrix System for Dental use Description: Add-On ...
Rogin Dental Veterinary Endodontic Files of Dentistry Treatment for animals​ Features: High-strength ...
Barbed Broaches Veterinary Endo Files for Pets Special Design for Veterinary Patients Product Name ...
Veterinary Dental Files Stainless Steel K Files and H Files and K-Reamers for Animal Endodontics ---...
Veterinary Paste Carriers for Vets Spiral Lentulos 25mm 31mm 60mm #25-40 ​ Product Name Veterinary ...