Specifications
Sensor block design.Simple operation,flexible & diversified output signal.Economic & Efficient.Succession, short delivery.
QB2000N/T is a fixed pipeline gas detecting transmitter, with 4-20 mA or RS485 ModBus RTU output proportional to combustible gas leakage concentration with original imported catalytic combustion sensor. It monitors
combustible gas(LPG) leakage by natural diffusion. It is flexible,
durable, accuracy, stable and etc. and it can be directly connected
with DCS systems or Central unit. With relay output, once the concentration exceed the preset alarm
point(threshold) it will start the acoustic-optical alarm on the
central unit and drive the external equipment like exhaust fans.It has been widely used in petrol, chemistry, metallurgy, artifice,
gas transportation, biological medicine and water procession etc.
![](http://img.everychina.com/nimg/8c/82/7e15bc18f48e96c6ec304257cbf6.jpg)
Characteristics:
- 4-20mA analog output(3+ channel) for direct communication to DCS
system, RS485 ModBus output for central unit
- Relay output for connecting external device
- LCD display screen(LED display screen optional)
- Sensor module(block) design on -spot replacement s and automatically
distinguish sensor fault and current display fault simultaneously.
- Password verification for repeat operation, avoid fault operations.
- -40~+70°C following compensation for accurate detecting.
- Second grade visual alarms on-site and Relay(connected with
audible/visual alarms or drive exhaust device).
- User-selectable alarm setpoint(s).
- Note: QB2000N is with the digital display screen but QB2000T is
without the digital display screen.
- Especially for pipeline gas leak usage.
Technical parameters:
- Sensor type: original imported catalytic combustion sensor for
combustible gas.
- Range: 0-100%LEL
- Resolution: 1%LEL
- Accuracy:<= + 3% F.S
- Response time:T90<30s.
- Working current:≤50 Ma
- Output signal: 4 to 20mA standard signal(RS485 output optional)
- Power supply to the detector terminals: 16~30V DC.
- Ambient Parameter: Temperature:-20°C~+60°C. Humidity: < 90%(without condensating)
- Type of cable: 3 or 4 active wires screened between detector and
centralized unit. 3×1.5mm2 for 4-20mA signal OR 4*1.5mm2 for RS485
signal, external diameter: >=10mm
- Transmition Distance:<=1000meter
- Mounting Screw thread: G1/2.
- Weight:1200g.
- Anti-explosion Class: Ex d IICT6Gb
- Protection Class:IP66.
![](http://img.everychina.com/nimg/29/7f/b858395fa91f28b95873d271d01a.jpg)
Characteristics:
◆RS485 analog output for direct communication to central unit
◆Relay output for connecting external device
◆LED display screen
◆Sensor module(block) design on -spot replacement s and
automatically distinguish sensor fault and current display fault
simultaneously.
◆Password verification for repeat operation, avoid fault
operations.
◆ -40~+70℃ following compensation for accurate detecting.
◆ Second grade visual alarms on-site and Relay(connected with
audible/visual alarms or drive exhaust device).
◆User-selectable alarm setpoint(s).
Detailed image: