2Volt 600Ah Deep Cycle Gel Battery UPS System Back Up Full Capacity
 
Description

Deep Cycle Gel battery is a battery in which the electrolyte is in gel state, which belongs to a development classification of lead-acid battery, the method is to add gelling agent to sulfuric acid, so that the sulfuric acid electrolyte becomes gel state. Gel battery with a smaller industrial cost, manufacturing a higher quality battery, its discharge curve is straight, the inflection point is high, its energy and power than conventional lead-acid battery is more than 20%.

 

ModelNominal VoltageCapacity C10WeightDimension
HeightLengthWidth
VAhkgmmmmmm
JGFM 100-221007.2205172102
JGFM 150-221509320172102
JGFM 200-2220013329171111
JGFM 300-2230018330171151
JGFM 400-2240025329211176
JGFM 500-2250028331241172
JGFM 600-2260035331301175
JGFM 800-2280048333410175
JGFM 1000-22100062329470175
JGFM 1500-22150096343401351
JGFM 2000-222000123343491351
JGFM 3000-223000180341712353

 


 
Product Features

  • Product name: Deep Cycle Gel Battery
  • Capacity range: 100Ah-3000Ah
  • Voltage class: 2V
  • Float charge voltage: 2.23V-2.25V
  • Equalized charge voltage: 2.35V-2.40V
  • Long working life: 10years
  • Low self-discharge rate: ≤3%/month
  • High sealed reaction efficiency: ≥99%
  • Widen operation temperature rang: -30℃~55℃
  • Excellent production process, high battery consistency
  • Specialized plate grid structure, smaller plate face spacing design, good high power discharge performance, excellent charge acceptance ability

Advantages

  • Product name: Deep Cycle Gel Battery
  • Safe to use, conducive to environmental protection, belongs to the real sense of the green power
  • Wide range of adaptable environment (temperature), especially good performance in low temperature, suitable for northern alpine area.
  • Good seismic performance, can be used safely in various harsh environments.

Application

  • Standby power supply for ships, maritime, petrochemical systems, etc
  • Solar, wind power and wind
  • Photovoltaic complementary energy storage system
  • No utility power, poor grid areas
  • Hybrid power supply system

Compliant standards

  • IEC60896-2-1995
  • TD/T 799-2010
  • GB/T 19638.2-2005
  • GB/T22473-2008
  • YD/T1360-2005
  • JISC8704-2:1999
  • Passed ISO9001.ISO14001, GB/T28001-2001, CE,
  • TLC, CGC certificate

Use of Deep Cycle Gel Battery

  • Product name: Deep Cycle Gel Battery
  • Check before charging and discharging: Before charging and discharging, the insulation of the charging equipment should be checked to see if it is good. Specific method: use 500V megohmmeter to measure the DC charging screen bus not less than 10MΩ.
  • Initial replenishment of electricity: Before putting the battery into use after installation and inspection, it should be balanced and supplemented with 14.1V balanced charging voltage at 25℃ for a single battery, and charged in a constant voltage current-limiting way for the battery pack. The maximum charging current is set to 0.25C10A.
  • Discharge: 1) 12V battery charging and discharging, 250Ah battery with a current of no more than 25A for 10 hours to discharge until the battery termination voltage of 10.8V or more, do not over discharge.

    2) During the discharge process, measure and record the battery voltage, discharge current and ambient temperature every hour, pay attention to the change of ammeter and battery voltage at any time, when the voltage drops to about 12.0V, change to half an hour test. When the measured voltage is 10.8v, stop discharging, open the discharge switch, the discharge is over. And record the discharge termination time, battery voltage, ambient temperature.

    3) After discharge, the battery should be recharged in time, to prevent acidification of the poles, the discharge-charging interval should not exceed 8 hours, so it must be balanced within 8 hours to replenish the electricity, the average charging voltage is set to 14.1V (the average of the measured value of the positive and negative terminals of the battery at 25℃), and the maximum charging current is set to 0.25C10A. The battery will run normally with the float charging voltage of 13.5V. Battery 13.5V.

    4) After discharge, check the discharge capacity at 25℃, it should be not less than 85% of the rated capacity, i.e. 12V250AH battery is not less than 212.5Ah.
  • Temperature compensation: The above current and voltage setting values are the standard values when the ambient temperature is 25℃, if the gel battery working temperature is beyond the range of 20℃-30℃, the floating charge and average charge voltage should be corrected accordingly, the corrected voltage is, that is, for every 1℃ increase in temperature, the floating charge voltage is reduced by 5.5mV, and for every 1℃ decrease in temperature, the floating charge voltage is increased by 5.5mV.

Hot Products

Complete 3000w 48vdc 220vac Off Grid Solar Power System Residential Description An Off Grid Solar ...
Monocrystalline Silicon 3000 Watt Solar Energy Off Grid System For Home Description 3000 Watt Solar ...
3000 Watt 48vdc 220vac Off Grid Solar Power System Home Use Rooftop Description Off Grid Solar Power ...
5000 Watt 48vdc 220vac 380vac Off Grid Solar Power System Solar Power Generator Description Off Grid ...
5000w 48vdc 220vac 380vac Off Grid Solar Power System Solar Kit Ground Description Off grid solar ...
5000watt 48vdc 220vac 380vac Off Grid Solar Power System Independent Electricity Description Off ...