1. All the parts contacting the products are made of AISL 316L
stainless steel, the surface roughness reaches Ra≤ 0.5 um
2. The inner circle of the chest has a smooth transition without
dead corner, no objects accumulated.
3. Consider for user, the structure is easy to clean
4. Option for steam sterilization or chemical sterilization.
Except for the above, we can also provide automatic running CIP(
on-site cleaning) and SIP( steam sterilization) functions to ensure
the high quality of cleaning and the sterilization of the
equipment.
SIP: Use overheat pure steam (121º C)
1. Equipped with cooling water jacket, after sterilizing, it can
fast reduce the temperature of chest (if less than 20m2, the
equipment is optional, if larger than 20m2, the equipment is
standard configuration).
2. Optional pneumatic door lock, it locks automatically.
3. Use import sterilization filter to ensure the absolutely
sterilized air coming into equipment.
4. The chest and various kinds of container and tube are all
wrapped with import insulating layer to efficiently avoid from heat
transmission
5. Can carry out constant humidity control to the refrigeration
humidity
6. Equipped with water circulation pump capable to eliminate
residual water in sterilization layer
CIP:
1. The high-pressure clean water thoroughly wash inner surface of
the chest and condenser
2. Equipped with large flow rate CIP pump, fixed with CIP tubing
that automatically drains the residual water.
3. Use rotary and fixed nozzle with 360-degree spray.
4. The hydraulic system uses isolated retractable corrugated tube
1. Uses world famous brand e. G. Frescoed Deafness Copeland Castel
Edwards and etc.
2. The system, uses double stage half sealed piston compressor to
reach first class temperature reducing
Speed rate and the lowest temperature in China
3. The system, power equipped is much greater than needed to
efficiently ensure the refrigeration performance
4. Digital and module design has an high protection to ensure the
system to run normally and stably.
5. The powerful refrigeration system liquid spray cooling system
and other protection installations keep to the best working
temperature and high system reliability
6. The sensitive transuding system can provide alarm and protection
in time against again abnormal running situation
7. Uses refrigerant conforming to the world environment protection
requirement such ad HCFCR22 and HFCRA for choice
8. Special synthetic lubricating oil can eliminate various kinds of
problem due to high temperature of normal mineral oil.
The reliable vacuum system:
The vacuum system of the freeze drier provides a necessary pressure
environment to freeze drying procedure. Cooperating with condenser
it can reach the vacuum level required by the freeze-drying
procedure To make the system run stably under high vacuum situation
the key point is the performance of the vacuum pump and the valve
seal and instrument that cooperate with the pump.
Control and optimum disposition
The control system of the freeze drier provides a reliable whole
procedure control for the freeze drier. It has advanced functions
of display, control, recording, printing, and alarming.