High Efficient Carbon Steel Fin Tube Boiler Economizer In Power Plant

 

Quick Details Specifications

 

As a kind of environmental protection equipment, economizer is the essence of a heat exchanger, both through two existed in the equipment for heat transfer temperature difference of the medium, to the secondary utilization of equipment, due to the burning boiler industry more for gas, use of the heat exchanger is commonly gas gas heat exchanger, air heat exchanger, water is usually installed in the tail gas boiler flue gas recycling waste heat of smoke directly.


The boiler economizer is an indispensable mechanical device for coal fired boilers, and is located at the boiler flue, where heat is captured from the flue gas in order to pre-heat cold water inlet or heat the boiler feed water. Our economizers are generally made of 20 low and medium pressure boiler pipes, 20G seamless steel tubes or ASME grade steel tubes. It reduces the flue gas temperature and maximizes the heat recovery to help customers reduce fuel costs. When entering the steam drum, the temperature of the feed water is increased after it has been heated using the economizer. The thermal stress caused by the temperature difference between the steam drum wall and the feed water is reduced, which reduces the shrink and swell in the steam drum. Our economizer is an excellent, less expensive replacement for high temperature boiler water wall tubing, thus reducing manufacturing costs for coal fired boilers.

 

(1) The economizer is a steam generation system as like a boiler. when the exhaust gas discharge from the engine cylinder through the exhaust valve it goes to the boiler for generate steam by heating of water.

 

(2) After those gas it goes through the economizer the remaining exhaust gas temperature is heated the water in economiser. it help to generate steam, and it is improving the efficiency and save the fuel consumption

 

(3) An economizer uses the waste heat from the boiler exhaust, that would otherwise be lost to atmosphere to (in most cases) preheat the feed water into the boiler.This improves the boiler efficiency and reduces fuel costs.

 

Competitive Advantage

 

1.Fuel saving: After the high temperature fuel gas released by fuel combustion transfers to the boiler water wall tubing, superheater, and reheater, the temperature is extremely high, the economizer makes it ideal for preventing heat loss. The economizer located at the flue of the boiler reduces the flue gas temperature, and maximizes the heat recovery to lower customer fuel costs.

 

2.Improvement of boiler steam drum working conditions: When entering the steam drum, the temperature of the feed water is increased after it has been heated using the economizer. The thermal stress caused by the temperature difference between the steam drum wall and the feed water is reduced, thus reducing the shrink and swell of the steam drum, and extends the service life.

 

3.Cost reduction of coal fired boilers: Water is being heated in the boiler economizer made using low temperature material. This makes the economizer a less costly replacement for high temperature boiler water wall tubing, and reduces overall boiler manufacturing costs.

 


Economizers must be sized for the volume of flue gas, its temperature, the maximum pressure drop allowed through the stack, what kind of fuel is used in the boiler, and how much energy needs to be recovered. Economizers designed for natural gas only, would likely plug-up if installed on a coal boiler and would face increased risk of corrosion if installed on an oil-fired boiler. Some units are designed to keep the flue gases above condensation temperature, and others are made of materials that resist the corrosive effect of condensed flue gases.

Highly Accuarcy Industrial Coal Fired Boiler Stack Economizer For Power Plant

 

 

 

Parameters

 

DescriptionBoiler economizer
MaterialAlloy steel, Carbon steel, SA210C ,SA213T22, etc.
Material standardASTM, EN or ISO etc.
DimensionCustomization
Weight

Min: 10 ton

Max.:1000 ton

Smelting Process:EF+LF + VD
ProcessMaterial→Ingot → Hot/Cold-Rolling→ Heat treatment (Normalizing+ tempering) → Inspection →rough machining→UT →2nd Heat treatment →finishing machining →Inspection
UT standardASTM A388 or EN10228, etc
 

*Note:HD BOILER can bespoke special type of economizer according to customer's requirement.

 

Internal heat exchangers

 

1.Subcooling may also be produced by superheating the gas leaving the evaporator and heading to the gas compressor.

2.These systems withdraw heat from the liquid line but heat up the gas compressors suction.

3.This is a very common solution to insure that gas reaches the compressor and liquid reaches the valve.

4.It also allows maximum heat exchanger use as minimizes the portion of the heat exchangers used to change the temperature of the fluid,and maximizeds the volume in which the refrigerant changes its phase.

 


 

Hot Products

ASME Standard Boiler Economizer Made of SA210A1 Tubes with 210° Shields for Waste Incinerator ...
Boiler Economizer Banks Made of CS Tubes in ASME Standard for Waste Incinerators​ Product Introdutio...
Waste Heat Recovery H Fin Tube High Frequency Welding Industrial Boiler Economizer ASME Performance ...
SA210A1 Tubes Made Boiler Economizer With Shields For Waste Incinerator Product Introdution ...
Carbon Steel Base Tubes Made Boiler Economizer With Tube Shields For Waste Incinerator Product ...
SA210A1 Tubes Made Boiler Economizer Banks With SA240-309S Shields For Waste Incinerator Product ...