Home Companies Changsha Sinocare Inc

Russian Version Blood Glucose Meter Kit Alternate Site Testing 0.6ul Blood Volume Diabetes Sugar Meter Glucometer

Changsha Sinocare Inc
Active Member

Contact Us

[China] country

Address: No.265 Guyuan Road Hi-tech Zone,Changsha,Hunan,China,410205

Contact name:

Inquir Now

Changsha Sinocare Inc

Russian Version Blood Glucose Meter Kit Alternate Site Testing 0.6ul Blood Volume Diabetes Sugar Meter Glucometer

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

 

Russian Version Blood Glucose Meter Kit

 

 

Alternate Site Testing 0.6ul Blood Volume Diabetes

 

 

Sugar Meter Glucometer

SAFE-ACCU

BLOOD GLUCOSE MONITORING SYSTEM

SPECIFICATION

FAD-GDH System

Blood sample:fresh capillary whole blood

Calibration sample:venous plasma

Test range:20-600mg/dL(1.1-33.3mmol/L)

Test time:10s

Blood volume:0.6ul

HCT:30-60%

Expiry date:24 months

Memory:200 test results

Battery lifetime:above 1000 times

 

 

 

 

Features

 

1.Memory with capacity for 200 results
2.Automatic strips ejections
3.0.6 ul blood sample

4.No coding
5.Virtually pain free glucose testing
6.Automatically applying blood sample

 

 

 

 

Safe Accu blood glucose monitoring system is easy to operate, convenient and speedy. It can be applied to medical organizations and patients with diabetes mellitus.

 

First step: prepare the components you will use

 

1Batteries
2Glucometer
3Strip vial
4Lancing device
5Lancets

 

Wash your hands, rinse and dry completely.

 

Screw off the cap of the lancing device. Insert a lancet into the lancet holder and push down until is fully seated. Note that the lancet is for one-time use only

Twist off the protective cap until it separates from the lancets.

Replace the lancing device cap and set the puncture depth to the desired number.

 

Pull back the cocking control until it makes a click, and then release. Now the lancing device is ready to use.

 

Remove a new test strip within the valid expiration from vial. After taking the strip, immediately cover the vial. To avoid losing efficiency. Insert test strip into the strip slot, the test strip is suggested to use up within 3 minutes. The meter turns on automatically. When the blood symbol starts blinking, the meter is ready to use.

 

 

Use a 75% cotton ball with alcohol at the blood sample site for disinfection, be careful not to use iodine or disinfectant containing "iodine" disinfectant. Once the alcohol has evaporated cleanly, align the prepared puncture device with the disinfected skin and press the button to collect the blood. Use your thumb to resist the lower part of the puncture device to help the blood draw ..

 

 

To obtain best accurate results, wipe off the first drop of blood and squeeze another.Apply the blood sample to the opening of the absorbent channel of the test strip until the confirmation window is fully covered with blood. The meter will display your blood glucose value after several seconds.

 

 

Push strip ejector to eject the tested strip automatically, twist off the lancets, cover its cap and place it properly according to Medical Waste Management Regulations.

 

Application

 

  • The Safe-Accu Blood Glucose Monitoring system is intended for use outside the body(in vitro diagnostic use) and should not be used for the diagnosis of or screening of diabetes.

 

  • The Safe-Accu Blood Glucose Test Strip is intended to be used with the Safe-Accu Blood Glucose Meter to quantitatively measure glucose(sugar) in capillary whole blood samples drawn from the fingertips or venous whole blood samples.

 

  • The Safe-Accu Blood Glucose Test Strip is intended for use by people with diabetes mellitus in the home and by healthcare professionals in clinical setting as an aid in monitoring the effectiveness of diabetes control.

 

 

 

ABOUT SINOCARE INC.

 

  • Leading diabetes management expert in China and BGM expert in the world.
  • Provide customers with safe, accurate and affordable products.
  • Sinocare always dedicates itself to developing BGM systems by applying the cutting-edge biosensor and manufacturing technology.

Hot Products

Life Time Warranty Diabetes Glucose Meter With 7/14/28/60/90 Testing Result Average Light Warning ...
Accurate Diabetes Glucose Meter Automatic Applying Blood Sample 24 Months Expiry Date No coding ...
No Coding Diabetes Blood Sugar Test Machine In Accuracy Result Safe Accu 200 test results MOQ 3000 ...
Life Time Warranty Diabetes Glucose Meter With 7/14/28/60/90 Testing Result Average Light Warning ...
Accurate Diabetes Glucose Meter Automatic Applying Blood Sample 24 Months Expiry Date No coding ...
No Coding Diabetes Blood Sugar Test Machine In Accuracy Result Safe Accu 200 test results MOQ 3000 ...