Home Companies Biovantion Inc.

High Precision Laboratory Or Hospital High Precision RUO Human Vitamin D ELISA Kit

Biovantion Inc.

Contact Us

[China] country

Trade Verify

Address: Room230/232, Building 1, No.538 YongfengTun, Haidian District, Beijing

Contact name:Steven

Inquir Now

Biovantion Inc.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

High Precision Laboratory Or Hospital High Precision RUO Human Vitamin D ELISA Kit

Country/Region china
City & Province beijing beijing
Categories Respiratory Equipment
InquireNow

Product Details

                                                        Human Vitamin D ELISA Kit 

INTENDED USE

Our Human Vitamin D ELISA kit is to assay Vitamin D levels in Human serum, plasma, culture media or any biological fluid.

 

Product detailsDescription
DeliveryWithin 48 hours
Packaging Specifications8 x 12 strips, 96 wells
Country Of OriginChina
Manufacturer18 months
Preservation method2℃-8℃
SpecimenWhole blood
Assificationclass1
TypeElisa Test Kit

 

Sample preparation

1. Serum preparation

After collection of the whole blood, allow the blood to clot by leaving it undisturbed at room temperature. This usually takes 10-20 minutes. Remove the clot by centrifuging at 2,000-3,000 rpm for 20 minutes. If precipitates appear during reservation, the sample should be centrifugated again.

2. Plasma preparation

Collect the whole blood into tubes with anticoagulant (EDTA or citrate). After incubated at room temperature for 10-20 minutes, tubes are centrifugated for 20 min at 2,000-3,000 rpm. Collect the supernatant carefully as plasma samples. If precipitates appear during reservation, the sample should be centrifugated again.

3. Urine samples

Collect urine into aseptic tubes. Collect the supernatant carefully after centrifuging for 20 min at 2,000-3,000 rpm. If precipitates appear during reservation, the sample should be centrifugated again. The preparation procedure of cerebrospinal fluid and pleuroperitoneal fluid is the same as that of urine sample.

4. Cell samples

If you want to detect the secretions of cells, collect culture supernatant into aseptic tubes. Collect the supernatant carefully after centrifuging for 20 min at 2,000-3,000 rpm. If you want to detect intracellular components, dilute the cells to 1X100/ml with PBS (pH 7.2-7.4). The cells were destroyed to release intracellular components by repeated freezing and thawing. Collect the supernatant carefully after centrifuging for 20 min at 2,000-3,000 rpm. If precipitates appear during reservation, the sample should be centrifugated again.

5. Tissue samples

Tissue samples are cut, weighed, frozen in liquid nitrogen and stored at -80℃ for future use. The tissue samples were homogenized after adding PBS (pH 7.4). Samples should be operated at 4℃. Collect the supernatant carefully after centrifuging for 20 min at 2,000-3,000 rpm. Aliquot the supernatant for ELISA assay and future use.

 

Materials provided with the kit

Notes:

  • Store the kit at 4°C upon receipt.The kit should be equilibrat4ed to room temperature before the assay. Remove any unneeded strips from Human Vitamin D Antibody-Coated plate, reseal them in zip-lock foil and keep at 4°C.
  • Precipitates may appear in concentrated washing buffer. Please heat the buffer to dissolve all the precipitates, which will not affect the results.
  • Accurate pipette should be used to avoid experimental error. Samples should be added to the Microplate in less than 5 minutes. If a large number of samples are included, multiple channel pipette is recommended.
  • Standard curve should be included in every assay. Replicate wells are recommended. If the OD value of the sample is greater than the first well of standards, please dilute the sample (n times) before test. When calculating the original Vitamin D concentration, please multiply the total dilution factor (XnX5).
  • In order to avoid cross-contamination, Microplate sealers are for one-time use only.
  • Please keep Substrate away from light.
  • All the operation should be accordance with the manufacturer's instructions strictly. The results determined by the Microtiter Plate Reader.
  • All the samples, washing buffer and wastes should be treated as infectious agents.
  • Reagents from different lots should not be mixed.

 

Storage and validity

1.Storage: 2-8℃.

2.validity: six months

Hot Products

1 Human Anti-Mullerian Hormone(AMH)ELISA INTENDED USE This kit is used to assay the Anti-Mullerian ...
25-OH Vitamin D ELISA TEST KIT INTENDED USE Detection Kit for 25-OH Vitamin D (Enzyme-Linked ...
Anti-ACA IgM ELISA Test Kit (Serum/Plasma) INTENDED USE This kit is a qualitative detection of human ...
Thyroid-stimulating hormone(TSH) ELISA Test Kit INTENDED USE Detection Kit for thyroid-stimulating ...
Thyroxine(T4)ELISA Test Kit (Serum) INTENDED USE Detection Kit for thyroxine(T4)(Enzyme-Linked ...
Triiodothyronine(T3) ELISA Test Kit INTENDED USE Detection Kit for 3,5,3'-Triiodothyronine(T3)...