Home Companies Guangzhou BioKey Healthy Technology Co.Ltd

Multiplex Respiratory Syncytial Virus RSV Streptococcus Pneumoniae Adenovirus PCR Test

Guangzhou BioKey Healthy Technology Co.Ltd

Contact Us

Trade Verify

Address: Add:No.2, Ruitai Rd, Guangzhou Hi-Tech Industrial Development Zone, 510670, CHINA

Contact name:Lisa

Inquir Now

Guangzhou BioKey Healthy Technology Co.Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Multiplex Respiratory Syncytial Virus RSV Streptococcus Pneumoniae Adenovirus PCR Test

City & Province guangzhou
Categories Rubber Product Making Machinery Parts
InquireNow

Product Details

Multiplex Respiratory viral RT-PCR test kit Lyophilized

 
Intended use:
 

This kit is used for in vitro qualitative detection of SARS-CoV-2/Influenza A+B/RSV/Adenovirus/M.pneumoniae from patients with respiratory tract infection. The test results are for clinical reference only, it cannot be used alone as the basis for the diagnosis or exclusion of cases

 

Test Principle:


The kit adopt TaqMan fluorescent probe method. For the highly conserved and specific region of SARS-CoV-2/Influenza A+B/RSV/Adenovirus/M.pneumoniae, the primer probes, together with RT-PCR reaction solutionfor fluorescent detection are designed and labeled with different fluorescent groups. On the fluorescence quantitative PCR instrument, the real-time fluorescence quantitative PCR detection technology is used to realize the rapid detection of SARS-CoV-2/Influenza A+B/RSV/Adenovirus/M.pneumoniae through the change of fluorescent signal.The detection system contains positive internal control, used to monitor whether the nucleic acid extraction process is normal.The kit adopt TaqMan fluorescent probe method. For the highly conserved and specific region of SARS-CoV-2/Influenza A+B/RSV/Adenovirus/M.pneumoniae, the primer probes, together with RT-PCR reaction solutionfor fluorescent detection are designed and labeled with different fluorescent groups. On the fluorescence quantitative PCR instrument, the real-time fluorescence quantitative PCR detection technology is used to realize the rapid detection of SARS-CoV-2/Influenza A+B/RSV/Adenovirus/M.pneumoniae through the change of fluorescent signal.The detection system contains positive internal control, used to monitor whether the nucleic acid extraction process is normal.

Biokey Multiple Respiratory PCR testing solution.p...


Product components:

 

1. BIK-QL-H004:

No.ComponentsAmount
1PCR Enzyme Mix (Lyophilized)96 tests/bottle
2Primer-Probe Mix 1 (SARS-CoV-2/Influenza A+B )50 μL/vial
3Primer-Probe Mix 2 (RSV/Adenovirus/M.pneumoniae)50 μL/vial
4Enzyme Mix Buffer (5×)400 μL/vial
5Positive Control100 μL/tube
6Negative Control100 μL/tube
7RNase-free water1mL/tube
8Paraffin oil1.5mL/tube*2

 

2. BIK-QL-H004S:

No.ComponentsAmount
11 (SARS-CoV-2/Influenza A+B Mix (Lyophilized))24 tests/kit
22 (RSV/Adenovirus/M.pneumoniae Mix (Lyophilized))24 tests/kit
3Positive Control100 μL/tube
4Negative Control100 μL/tube
5RNase-free water1mL/tube
6Paraffin oil1.5mL/tube

 

Note: Do not mix the components from different batches for detection. The Positive Control of SARS-CoV-2/Influenza A+B/RSV/Adenovirus/M.pneumoniae and internal control were constructed artificially, and they were not infectious.

 


Storage and stability:

 

 
1.The kit should be stored under -20±5℃ and protected from light. Its period of validity is 12 months. Products can be shipped at room temperature for 7 days.
2.Repeated thawing and freezing should be no more than 3 times.
 

PCR amplification condition:
 

PCR amplification according to the following procedure:

 

StepCycle numberTemperatureTime
1150℃10min
2194℃3min
34094℃10s
60℃30s Collect the fluorescent
 
Select the detection channels as following:
Select FAM,VIC/HEX,ROX and CY5 channels
 
Quality control:
 
Negative Control: None of the FAM, VIC/HEX, ROX & IC (CY5) channels have a Ct value or Ct > 40;
Positive Control: FAM, VIC/HEX, ROX & IC (CY5) channels Ct ≤ 30;
The above two items should be met simultaneously in one experiment. Otherwise, the experiment is invalid and should be repeated.
 

Interpretation of test results:

 

RSV/Adenovirus/M.pneumoniae reaction:

 

FAM

(RSV)

VIC/HEX

(Adenovirus)

ROX

(M.pneumonia)

CY5

(IC)

Interpretation test results
1----Result invalid ,test again
2+--+/-RSV(+)
3-+-+/-Adenovirus(+)
4--++/-M.pneumonia(+)
5++-+/-RSV,Adenovirus(+)
6+-++/-RSV,M.pneumonia(+)
7-+++/-Adenovirus, M.pneumonia (+)
8++++/-RSV, Adenovirus, M.pneumonia(+)
9---+Negative(-)


 Operation details please check from IFU

Hot Products

Necrotizing Hepato-pancreatitis Bacterium Nucleic Acid Detection Kit (Real time PCR, Lyophilized) ...
Tilapia Lake Virus Nucleic Acid Detection Kit (Real time PCR, Lyophilized) Intended use: This kit is ...
Multiplex fluorescent probe Humam Respiratory viral RT qPCR test kit ( Lyophilized ) Intended use: ...
SARS-CoV-2 Influenza A+B RT-PCR test kit (Lyophilized) Intended use: This kit is used for in vitro ...
Multiplex 6 parameters Respiratory viral fluorescent Tagman probe primers PCR reagent test kit ...
Multiplex Respiratory viral RT-PCR test kit (Lyophilized) Intended use: This kit is used for in ...