Home Companies Beijing KES Biology Technology Co., Ltd.

Medical CE Approved E-Light IPL RF Beauty Equipment For Wrinkle Removal

Beijing KES Biology Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.15,Zone 2,Mafang Industrial Park,Zhongguancun Science and Technology Park, Pinggu District ,Beijing

Contact name:Jackie

Inquir Now

Beijing KES Biology Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Medical CE Approved E-Light IPL RF Beauty Equipment For Wrinkle Removal

Country/Region china
City & Province beijing beijing
InquireNow

Product Details

Medical CE Approved E-light IPL RF Beauty Equipment for Wrinkle Removal
 

Applications

 
 

750-1200nmHair Removal (Skin Type IV)
690-1200nmHair Removal (Skin Type III)
640-1200nmHair Removal (Skin Type I & II ) ; Wrinkle Removal
590-1200nmPigmentation and Vascularity; Skin Rejuvenation
560-1200nmVascular and Pigmented Lesions; Skin Rejuvenation
530-1200nmSkin Rejuvenation; Superficial Vascular Lesions
510-1200nmSuperficial Vascular Lesions
480-1200nmLight Pigmentation
430-1200nmAcne
RF TreatmentSkin Tightening and Face Lifting

 

 

 

How it works?


E-Light is the perfect combination of IPL technology with Bi-polar Radio Frequency (RF) and Skin Contact Cooling.
Radio Frequency is independent of melanin and thus independent of skin type. With Radio Frequency, increased selectivity and deeper dermal penetration would be achieved, thus lower energy is applied during the IPL treatment. Uncomfortable feeling during the IPL treatment will be decreased significantly and better result can be expected.  That is, less optical energy (IPL), when synergistically combined with Bi-polar RF, improves the safety factor when treating all skin types.
Meanwhile, contacting surface cooling technology applied on the treatment probe head can eliminate the heat effect attributed to optical energy, and increase the resistance of surface skin, reduce the RF absorption of the surface skin, greatly improving both the treatment performance and safety.  The technology is equally applicable and effective to mild color target tissues.

 

 

Before And After

 

Unique Advantages


SHR mode:10 times/s
Intelligent + Professional mode = parameters setting automatically
Appearance design make excellent cooling
Strong system with 3 Capacitors and 2 power supplies!

 

Technical Specifications
 

Wavelength (Spectrum)

650-950nm(HR)
510-1200nm(SR) ,
430/530/640-1200nm (15*35mm)

Energy Density (Fluence)

1-26J/cm2(SHR)
1-60J/cm2(Normal)

Spot Size

15x50mm2 (HR);
10x40mm2 (SR);
15*35mm2 (interchangeable)

Pulse duration1-15ms
PulseSingle
Pulse Repetition Rate1-10Hz
Timer1-30s
IPL Peak Power2500W
CoolingContinuous Crystal contact cooling (-4°C-2°C ) + Air cooling + Closed water circulation cooling
Stand-by WorkingContinuously for 18 hours
Display10.4" True Color LCD Touch Screen
Electrical Requirements100-240VAC, 20A max., 50/60Hz
Net Weight60 kgs
Dimensions (WxDxH)

63*53*126cm

 
 

How to use  IPL ?

Step 1: Remove all visible hair in the area you wish to treat with your preferred hair removal method. If desired, the Braun Skin i·expert Smart IPL includes a Venus razor for easy surface hair removal. Ensure there is no hair remaining above the surface of the skin. Then pat your skin dry.

Step 2: select the standard head or the precision head depending on the size of the area you wish to treat. Plug in the Skin i·expert Smart IPL.

Step 3: Put the nozzle in full contact with the skin to make sure the product works correctly. If the light flashes white, a valid skin tone is detected. If not in proper contact with the skin, the device will not flash. In the case of a red light, there is not full contact or it is an invalid skin tone.

Step 4: For larger body areas use gliding mode: hold down the treatment button and glide along your skin. For smaller areas, press and release the treatment button. For sensitive areas or if it’s your first time, you can use the gentle or extra gentle mode.

Step 5: It is important to wipe clean the nozzle after every use.

Step 6: In the first phase of your treatment, treat once a week for 4 - 12 weeks. Then adjust to your needs (i.e. every 1-2 months).
 

Welcome to inquiry!!! Welcome to Beijing KES company!! 

























Hot Products

MED - 808 peak power 2000w net weight 43kgs portable diode laser hair removal painfree machine Model...
Portable 808 nm Diode Laser Hair Removal Equipment , 808nm 600w laser diode 14*14mm2 Model:MED-808 1...
Portable 808 nm Diode Laser Hair Removal Equipment , 14*14mm2 For Beauty Salon Model:MED-808 1. ...
Portable Diode Laser 808 Medical CE TUV Epicare Hair Removal Beauty Salon Equipment Model:MED-808 1. ...
Hot sales!!! High Quality 808 nm diode laser hair removal machine Function 808nm diode laser ...
2017 KES hot sell factory New tech TEC cooling System Germany bars beauty salon 808 diode laser hair ...