Home Companies BELONG INTERNATIONAL CO.,LTD

QY1500S-VC6018 AC/DC 60V18A 1330W intelligent battery charger for cleaning & sweeping machine

Active Member

Contact Us

[China]

Address: Suite 709, Reeco Tower, No. 255 Wubao Road Minhang District, Shanghai, China

Contact name:Winter Teng Email: sales@belong-inc.com

BELONG INTERNATIONAL CO.,LTD

QY1500S-VC6018 AC/DC 60V18A 1330W intelligent battery charger for cleaning & sweeping machine

Country/Region china
City & Province shanghai shanghai
Categories Skin Care

Product Details

 

1. General Information

 

AC/DC 60V18A intelligent charger, 120&220Vac rated input voltage, 100-240Vac input voltage range,

73.5V/18A output, 1330W max output power.

 

Protections against Over-voltage and Under-voltage on input; Over-voltage, Under-voltage and

Current-Limiting on output; Overheating, Reverse Polarity and Short Circuits.

 

2. Specification

 

Max Output PowerInput VoltageOutput VoltageOutput Current
1330W100~240Vac73.2~73.8Vdc16A~18A

 

 

 

 

3. Electrical Characteristics

 

InputItemTechnical StandardUnitNote
Rated Input Voltage120/220Vac 
Input Voltage Range100~240Vac 
Input Frequency Range47~63Hz 
Max Input Current≤6ARated load, and min input voltage
Input Power Factor>0.95 Rated load
ItemTechnical StandardUnitNote
OutputOutput Voltage73.5VVdc 
Output Current Range73.5V16 ~ 18A 
Voltage Precision73.5V±0.3Vdc 
Output Ripple and Noise73.5V≤(Vo X 0.5%)Vp-pmV 
Power-on Output Delay73.5V≤5S 

Output

Rise Time

73.5V≤100mS 
On/Off Overshoot Amplitude73.5V≤(Vo X 5%)Vp-pVRise to 90%Vo from 10%Vo, rated load
Recovery Time≤200uS 
Overall Efficiency>90%

Rated Vin=120/220Vac,

Rated output current=18A

Output Power Off Hold Time≥20mS 
TEMPCO±3mV/℃Negative temperature coefficient compensation

Protection

Alarm

&

Indicator

 

ItemTechnical StandardUnitNote
Output OVP≤(rated Vo) x110%V

Recover automatically

after the output returns to normal

 

Output CLP

≤(rated Io) x110%ANo auto recovery, current limiting or constant power output. Output interrupts are not allowed
Output SCPIo= 0AAAuto recovery
Input OVP>265VacAuto recovery
Input Overvoltage Recovery<260Vac
Input UVP<85VacAuto recovery
Input Undervoltage Recovery>90Vac
DC Output Indicator (ACT)Normal Output (LED)  
Red LEDYellow LEDGreen LED
StandbyONOFFOFF  
Less than 50% chargedSlow Flash(1/S)OFFOFF  
50%-75% chargedOFFSlow Flash(1/S)OFF  
75%-100% charged

 

OFF

 

OFF

Slow Flash(1/S)  
100% fully chargedOFFOFFON  
Power Failure Indicator (ALM)

Abnormal Output (LED)

 

  
Red LEDYellow LEDGreen LED

 

Battery Failure

Fast Flash(2/S)

 

OFF

 

OFF

  
OTPOFFFast Flash(2/S)OFF  

 

Inner Failure

 

OFF

 

OFF

Fast Flash(2/S)  
Safety RequirementItemTest ConditionNote
VISOIn-Out2500Vac/5mA/1minNo flashover or breakdown (Remove lightning protection devices in testing.)
In-GND2500Vac/5mA/1min
  

 

RISO

In-Out≥100MΩ@500VdcRemove lightning protection devices in testing.
In-GND≥100MΩ@500Vdc
Out-GND≥100MΩ@500Vdc

 

LC

 

In-GND

≤3.5mAVin=264Vac/50Hz
RG--≤0.1Ω 
Temp RiseOverall unitKey components: IEC60950/GB4943; Others: within its own normal operating temperature rangeFull load, and at the worst ambient temperature
Flame retardancyPCBGB4943.1/ IEC60950-1 V-0 
Other isolation materialGB4943.1/ IEC60950-1 V-1 
EMCEMI(CE)EN55014-1:2017 
(RE)EN55014-1:2017/CISPR22 CLASS B 
(Harmonic Current)EN61000-3-2: 2014 
EMS(ESD)EN61000-4-2:2009 
(RS)EN61000-4-3:2010 
(EFT)EN61000-4-4:2012 
(SURGE)EN61000-4-5:2014 
(CS)EN61000-4-6:2014 
(MS)EN61000-4-8:2010 
(DIP)EN61000-4-11:2004 

 

 

4. Environmental Condition

 

 

Item

 

Technical Standard

 

Unit

 

Note

Storage Temp-40~+85Storage for 24h, recover for 2h at AT
Operation Temp-25~+45 
RH5~90%Non-condensing
Heat DissipationIntelligent air cooling  
Altitude≤3000m 
Pressure70~106kPa 
MTBF≥200000hBellcore TR-332(Ta=25°C)
VibrationRandom vibration: 5-500Hz in 3 mutually perpendicular directions, 1m2/s3 at 5-10Hz, 3 m2/s3 at 10-200Hz, and 1m2/s3 at 200-500Hz, 20min per direction Normal working after testing.

Working vibration

Frequency: 5-9Hz, 9-200Hz

Amplitude: 1.5mm

Acceleration: 5m/s2

Time: 5-200Hz-5Hz at each axis, 5 cycles in total

 Normal working during testing.
Shock

Shock Waveform: half sinusoid

Peak acceleration: 60m/s2

Cycle: 11ms

Times: ±3 times at each axis, 18 times in total

 Normal working during testing.

 

5. Mechanical characteristics

Shell material: Aluminum Alloy

Outline dimension: L*W*H=281*177.5*83mm

Input socket: meets IEC standard

AC wires: 1.5m length

DC wire: 1.6m length

Output connector: 175A red Anderson connector or equivalent

Net Weight: 3.5Kg

 

 

6. Charging Curve

Lithium battery charging curve

 

Lead-acid battery charging curve

 

7. Application

 

 

Hot Products

Belong intelligent battery charger for cleaning & sweeping machine QY800S-VC6010 AC/DC 60V10A 740W 1...
1. General Information AC/DC 36V25A intelligent charger, 120&220Vac rated input voltage, 100-240Vac ...
1. General Information AC/DC 48V20A intelligent charger, 120&220Vac rated input voltage, 100-240Vac ...
1. General Information AC/DC 48V25A intelligent charger, 120&220Vac rated input voltage, 100-240Vac ...
1. General Information AC/DC 60V18A intelligent charger, 120&220Vac rated input voltage, 100-240Vac ...
1. General Information AC/DC 72V15A intelligent charger, 120&220Vac rated input voltage, 100-240Vac ...