Home Companies Jinan Shun Long Machinery Co., Ltd.

Side Manhole 1000l Conical Fermentation Tank With 3 Bar Pressure Vessels

Jinan Shun Long Machinery Co., Ltd.
Active Member

Contact Us

[China] country

Address: Room 220,No. 9-2,Shanda South Road,Licheng District,Ji'nan,Shandong,China (Mainland)

Contact name:Zhao

Inquir Now

Jinan Shun Long Machinery Co., Ltd.

Side Manhole 1000l Conical Fermentation Tank With 3 Bar Pressure Vessels

Country/Region china
City & Province shandong
InquireNow

Product Details

 

Side manhole 3 bar pressure vessels 1000L Conical beer fermenter

 

Technical parameter:

 

Food grade SS304, DIN32

Useful capacity: 1000L (+25% head space)

 

Inner: SS304. TH=3.0mm Outer: SS304.TH=2.0mm

100% TIG welding with pure argon gas shield

Interior Finish: Overall polishing to 0.6μm without dead corner

Insulation: Polyurethane; TH=80mm

Glycol Jacket for cooling

Dished head and 75 degree cone bottom

Top Manhole

CO2 blow-off arm with butterfly valve

Full sanitary sampling valve

Bunging valve 2 bar on CIP arm

Shockproof pressure gauge on CIP arm

Dry hopping port(φ100mm) with solid end cap

4 completely SUS304 heavy duty legs with leveling pad

Thermo well for high accuracy temperature sensor

Testing pressure 3bar keep 48 hours;

Working pressure 2 bar

 

 

 

 

100L200L300L500L1000L2000L3000L5000L
60 degree60606070707070
Single sectionSingleSingleSingleDouble sectionDoubleDoubleDouble/Three

 

 

II Brewing Equipment Installation

2.3 Fermenter

 

2.3.1 After the fermenter is in place, the equipment should be adjusted to ensure that the tank is straight and arranged in an orderly manner.

 

2.3.2 Install CIP L pipe, valves, pressure gauge, temp sensor and other accessories.

 

2.3.3 Install coolant inlet/outlet pipeline, valves and accessories.

 Brewing equipment commission

 

3.1.1 Rinse the device with water and fill it with water to test for leaks.

 

3.1.2 Turn on the wort pump to test leaks one by one. The wort pump must not be idling or reverse running.

 

3.1.3 For electric heating, the water level in the hot water tank/boiler must not be lower than the upper limit of the electric heating pipe, prohibiting the heating pipe from drying.

 

3.2.1 Connect the tap water pipeline, clean the fermentation tank one by one and carry out a pressure test, and maintain the pressure at 0.2 MPa for 2 hours. If the pressure does not change, prepare for cleaning.

 

3.2.2 The leak test of the ice water pipeline is performed together with the pressure test of the refrigeration system.

3.3.  Chilling system

 

3.3.1 The ice water tank is first cleaned with water, and then the water is leak tested. If there is no abnormality, the ice water pump can be turned on to conduct a hydraulic pressure leak test on the cooling pipeline to see if there is any leakage point.

 

Remarks: a. The power cable and the signal cable should be separated according to the regulations without any confusion.

b. The refrigerator needs to be installed by professionals, and the alcohol content in the ice water tank is above 35%.

c. The wort pump must not be unloaded or reversed.

★ Special attention: During the temporary storage of hot water in the fermentation tank, it is necessary to keep the CIP valve open. Otherwise, when the temperature drops, negative pressure will form in the tank, which will damage the tank of the fermenter!

 Special attention: When using the suction filtration method, it is necessary to adjust the frequency converter and carefully control the wort flow to maintain the stability of the return flow. Prevent the formation of vacuum in wheat slag layer and cause damage to the filter

★ Special attention: The level gauge is cleaned once every use, and the water is drained side by side.

★Special attention: During the wort filtration process, if the wort is unclear or difficult to filter, stir the mash for 10 minutes and re-flow until the wort is clear.

CIP washing attention

 

a. During the washing, pay attention to protection, and must be equipped with protective equipment during operation. It is strictly forbidden for the limbs to directly contact the alkaline solution.

b. It is prohibited to use the disinfectant containing Cl-, such as hot water, hypochlorous acid and chlorine, to sterilize the fermentation tank.

 

 

 

 

Hot Products

500L Beer brewing system equipment This type of 500L beer brewing system is design for different ...
500L beer brewing equipment with 2 vessels brewhouse stainless steel material for microbrewery ...
5 BBL micro beer brewing equipment for micro brewery stainless steel semi automatic control ...
500L Beer Brewing Equipment stainless steel material three vessles brewhouse Product Discretion: 1. ...
1000L beer brewing equipment stainless steel steam heating Company Profile Jinnan Shunlong machinery ...
200L Homebrew Beer Brewing Equipment For Home using / pilot brewery Product details Beer brewing ...