E26 Lamp cap gauge | go gauges for caps E26-7006-27D-3

 


“GO” GAUGE FOR CAPS CALIBRE «ENTRE» POUR CULOTS E26, E26/50x39, E26/51x39 & E26d

 

Dimensions in millimetres - Dimensions en millimètres
The drawing is intended only to illustrate the essential dimensions of the gauge.
Le dessin a pour seul but d’illustrer les dimensions essentielles du calibre.
For details of caps E26, E26/50x39, E26/51x39 and E26d, see sheets 7004-21A, 7004-130 and 7004-29 respectively.
Pour les détails des culots E26, E26/50x39, E26/51x39 et E26d, voir feuilles 7004-21A, 7004-130 et 7004-29 respectivement.

 

 

 

 

(1) Detail of thread. Right-hand thread.
(2) The sharp part of the edge of the thread at the entrance of the gauge shall be broken with a radius of 0,2 mm to 0,3 mm.
(1) Détail du filetage. Filet à droite.
(2) Le bord vif de la partie filetée à l'entrée du calibre doit être arrondi avec un rayon de 0,2 mm à 0,3 mm.

 

 

 

PURPOSE: To check the maximum dimensions of the screw thread and dimension T1min of E26, E26/50x39, E26/51x39 or E26d caps on finished lamps.
TESTING: When the cap on a finished lamp has been screwed into the gauge as far as it will go, the central contact shall touch surface X. When the lamp is removed from the gauge, at least two full turns shall be required to disengage the threads.
BUT: Vérification des dimensions maximales du filetage et de la dimension T1min des culots E26, E26/50x39, E26/51x39 ou E26d sur lampes terminées.
ESSAI: Lorsque le culot sur lampe terminée est vissé complètement dans le calibre, le contact central doit toucher la surface X. Lors de l'enlèvement de la lampe du calibre, au moins deux tours complets doivent être accomplis pour désengager les filetages.

 

Related gauges:

 

"NOT GO" GAUGE FOR E26, E26/50x39, E26/51x39 & E26d CAPS ON FINISHED LAMPS (Sh. 7006-29L-4)
"GO" GAUGE FOR CAPS E26, E26/50x39, E26/51x39 & E26d (7006-27D-3)
GAUGE FOR TESTING CONTACT-MAKING OF LAMPS FITTED WITH CAPS E26, E26/50x39,E26/51x39 & E26d (NON-SKIRTED) (7006-29-3)
E26d GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT (7006-29A-2)
E26d GAUGE WITH REFERENCE DIAMETER OF 23 mm FOR CAPS (7006-29B-2)
E26d GAUGE WITH REFERENCE DIAMETER OF 13,2 mm FOR CAPS (7006-29C-2)
E26d GAUGE WITH REFERENCE DIAMETER OF 10,4 mm FOR CAPS ON FINISHED LAMPS (7006-29D-1)

Hot Products

E26d Lamp Cap Gauge | Gauge With Reference Diameter Of 10.4mm For E26d Caps On Finished Lamps E26d...
E27 Lamp Cap Gauge | "NOT GO" Gauge for E27 Caps On Finished Lamps | 7006-28A-1 Purpose: to check ...
DIN-VDE0620-1 Plug And Socket Gauge For Measuring German Standard Plug And Socket Product informatio...
G5 Lamp Cap Gauge | "GO" Gauge For Bi-Pin Cap On Finished Lamps G13-7006-46A-3 Purpose: Purpose: to ...
G10q , GX10q, GY10q,GZ10q Lamp cap gauge , "GO" GAUGE FOR CAPS C G10q, GX10q, GY10q , GZ10q GO" ...
ISO 8124-1 2014 Stainless Steel Protrusion Test Gauge Technical Parameter Material Stainless steel ...