Neware Technology Limited |
|
Neware 8 Channel 18650 Battery Analyzer 21700 Cylinder Battery
Testing System
Neware Battery Charge and Discharge Test System , ranging from μA
single cell applications up to 1MW packs , is a high precision
system designed specifically for testing lithium ion battery cells
, modules , packs and capacitors .
It is suitable for product development, quality control , and
helpful to characteristic research , cycle life testing , product
screening, and quality assessment .
Windows - based software interface for easy operation .
Uses standard SQL data - base management .
Real - time monitoring windows and integrated graph / data windows
can set various working modes for measuring capacity and cycle life
of all types of rechargeable batteries , such as constant current
discharge , constant current charge , constant voltage charge ,
rest , as well as voltage , current , time , capability , negative
voltage slope , and other limit conditions .
The user can define the curve by different types such as voltage -
time curve , current - time curve , capacity - voltage curve ,
Loop times - charge / discharge capacity curve , loop times -
charge / discharge efficiency curve , etc . to make curves be
compared both by visually and statistically .
Provide timely instructions , warnings , and intelligent support .
Market - proven Testing System
Less than 20ms Response Time to Meet Rapidly Changing Power
Requirements
0.1 percent Full - scale Accuracy for Current and Voltage
10Hz Data Acquisition Frequency , 100Hz Optional
500ms Minimum Pulse Width More Than 1 Million Records Can Be
Processed
Time | Current Response Time | 1ms |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers |