Home Companies HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Vacuum Chamber Helium Leak Testing Equipment For Auto Condenser Evaporator

HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Contact Us

[China] country

Trade Verify

Address: No.6-36, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou, Guangdong, China

Contact name:Tessa Huang

Inquir Now

HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Vacuum Chamber Helium Leak Testing Equipment For Auto Condenser Evaporator

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

Vacuum Chamber Helium Leak Testing Equipment For Auto Condenser And Evaporator

 

Product information:

The Helium Leak Detection System is specially designed for leak test of auto parts like Condenser, Evaporator, Automobile radiator, Engine cooler, switch gears, and it is the most efficient industrial-scale automatic leak testing equipment for heat exchangers in market.

The system is able to run the following tests:

Leak detection with pressure decay method to find Gross Leaks.

Helium test with mass spectrometer to find Fine leaks. Helium Leak Testing Equipment

 

Features:

PLC control, touch screen display

All automatic leak testing with over all leak test

Non operator dependent

Back ground suppression technology, ensure precise testing

Automatic digital pass/Fail indication.

Ensure operation reliability

 

System Description:

The chamber helium leak test system proposed has the totally automatic cycle with manual load and unload of the tested piece.

The Test Cycle can be described in the following way:

Manual load of the tested piece in the Test Chamber.

Closure of the Chamber.

Evacuation of the Chamber to a value of vacuum suitable for Leak Test with Mass Spectrometer. During the evacuation of the Chamber, the system will run the following Tests on the tested piece:

Pressure decay to reveal Gross Leaks;

Tested piece evacuation;

Reaching a vacuum value suitable for transfer, that is to put the mass spectrometer in communication with the Test Chamber.

Reading of background, which is the residual Helium in the Test Chamber.

Pressurization of tested piece with Helium.

Leak test with Mass Spectrometer.

Ventilation of the Test Chamber (return to atmospheric pressure),

Helium Recovery from tested piece.

Opening of the Chamber

Manual unloads of tested piece.

 

Parameter:

WorkpieceCondenser, Evaporator, Automobile radiator, Engine cooler
Vacuum Chamber2 chambers ( Support customization)
Pressure for Gross Leak TestNitrogen / Compressed Air 4.2Mpa (Downward adjustable)
Gas for Fine Leak TestHelium
Detection leak rate1 x 10-5 mbar.l/s
Cycle Time30-60 sec./pcs
Helium RecoveryRecovery Rate ≥95%
Loading and unloading of productsManual Helium Leak Testing Equipment
Test CycleAutomatic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Products

Conductor Damage Degree Test Apparatus IEC 60069-1 Test Equipment Rate 10 ± 2 r/min Standard: IEC ...
IEC Test Equipment Pendulum Hammer Test Apparatus For Mechanical Strength Standard: IEC 60668-2-75...
Load Bank For Externally Ballasted Lamp Loads IEC Test Equipment Standard: IEC 60884-1 'Plugs and ...
Mandrel Test Device IEC Test Equipment 150N Test Force Manual Control Standard: IEC 61558-1 ‘Safety ...
IEC 60065 Figure 6 Test Equipment Dielectric Strength Test Instrument Standard: IEC 60065-1 ‘Audio, ...
IEC 60669-1 Test Equipment Self Ballasted Lamp Load Box Three Test Stations Standard for Self ...