Promass F has a long-standing reputation as a highly accurate sensor. Immune to fluctuating and harsh environments it is suited for the broadest range of applications. With its innovative remote transmitter Promass F 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures compliance and process safety at all times.
Highest process safety – immune to fluctuating and harsh environments
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in/outlet run needs
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Measuring principle operates independently of physical fluid properties such as viscosity or density
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Device properties
Mass flow: measurement error ±0.05 % (PremiumCal)
Medium temperature: -196 to 350 °C (-320 to 662 °F)
Nominal diameter: DN 8 to 250 (3/8 to 10")
Remote version with up to 4 I/Os
Backlit display with touch control and WLAN access
Standard cable between sensor and transmitter
Coriolis
Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: -196 to 350 °C (-320 to 662 °F).
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access.
DN 8 to 250 (⅜ to 10")
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602
(UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022);
1.4301 (F304)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
PN 100, Class 600, 63K
Standard: –50 to +150 °C (–58…+302 °F)
Option: –50 to +240 °C (–58…+464 °F)
High temperatur option: –50 to +350 °C (–58…+662 °F)
Option: –196 to +150 °C (–320 to +302 °F)
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F)
Standard: 1.4301 (304), corrosion resistant
Option: 1.4404 (316L)
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L);
1.4409 (CF3M) similar to 316L
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69.
Transmitter remote version: IP66/67, Type 4X enclosure
External WLAN antenna: IP67
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Status input
4-20 mA input
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC
CE, C-tick, EAC marking
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Calibration performed on accredited calibration facilities (acc. to
ISO/IEC 17025)
Heartbeat Technology complies with the requirements for traceable
verification according to ISO 9001:2008 – Section 7.6 a (TÜV
attestation)
MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic
liquids)
NTEP (Liquids other than water, LPG, cryogenic liquids)
MC (Liquids other than water, cryogenic liquids)
PED, CRN, AD 2000
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
cGMP
Kit power supply, 100-230VAC, Ex
Kit power supply, 24VDC, Ex
Kit pow.supply,100-230VAC/24VDC, Non-haz
Kit main elec.extend.,Promass500 dig.,Ex
Kit main elec.extender,500 dig., Non-haz
Kit ISEM extender, 500 digital, Ex
Kit T-DAT, 100/300/400/500/500 digital
ISEM electronic module, Promass 300/500
Kit module cartridge, 300/500, Ex
I/O module, slot 1, 300/500
Kit ISEM ribbon cable, 300/500
Kit ISEM ribbon cable, 500 digital
Kit conn.terminal option A, 300/500, Ex
I/O module, slot 2/3/4, 300/500
Kit conn.terminal option B, 300/500, Ex
Display module, 300/500/DKX001
Kit conn.terminal option C, 300/500, Ex
Kit terminal option A, 500 dig., Non-haz
Kit terminal option B, 500 dig., Non-haz
Kit terminal option C, 500 dig., Non-haz
Kit connection board, Promass 500, Ex
Kit connec.board, Promass 500, Ex, -50oC
Kit connec.board, Promass 500, Ex, -50oC
Kit cover, sight glass, Alu,Non-haz/Exde
Kit cover,glass, Alu, -50oC,Non-haz/Exde
Kit cover,glass, Alu, -50oC,Non-haz/Exde
Kit cover, sight glass, Alu, Exd
Kit cover, sight glass, Alu, -50oC, Exd
Kit cover, sight glass, Alu, -50oC, Exd
Kit cover, sight glass, cast, Ex
Kit cover, sight glass, cast, -50oC, Ex
Kit cover, sight glass, cast, -50oC, Ex
Kit cover gasket, sight glass/blind
Kit cover gasket,sight glass/blind,-50oC
Kit cover gasket,sight glass/blind,-50oC
Kit cover, electronic compart., Alu, Ex
Kit cover, electr.compart., Alu,-50oC,Ex
Kit cover, electr.compart., Alu,-50oC,Ex
Kit cover, electronic compart., cast, Ex
Kit cover, electr.compart.,cast,-50oC,Ex
Kit cover, electr.compart.,cast,-50oC,Ex
Kit cover gasket, electronic compart.,Ex
Kit cover gasket,elect.compart.,-50oC,Ex
Kit cover gasket,elect.compart.,-50oC,Ex
Kit cover, wall mount, Alu, Ex
Kit cover, wall mount, Alu, -50oC, Ex
Kit cover, wall mount, Alu, -50oC, Ex
Kit cover, wall mount, cast, Ex
Kit cover, wall mount, cast, -50oC, Ex
Kit cover, wall mount, cast, -50oC, Ex
Kit cover gasket, wall mount, Ex
Kit cover gasket, wall mount, -50oC, Ex