Home Companies CN Cable Group Co., Ltd.

110kV Compact High Voltage Power Cables XLPE Insulation HDPE Sheath

CN Cable Group Co., Ltd.
Active Member

Contact Us

[China] country

Address: No.80 Dianchang Road,High-Tech Industrial Zone, Zhengzhou,China

Contact name:Andrea

Inquir Now

CN Cable Group Co., Ltd.

110kV Compact High Voltage Power Cables XLPE Insulation HDPE Sheath

Country/Region china
City & Province zhengzhou henan
Categories Power Cables
InquireNow

Product Details

110kV High Voltage compact Power Cable XLPE Insulation HDPE Sheath

 

APPLICATION:

The high voltage power cables contained within this datasheet are suitable for the primary distribution of power up to a maximum network voltage of 110kV. Suitable for locations where mechanical protection is afforded by other means and where the additional protection of a moisture barrier has been determined not to be necessary, see 2XS(FL)2Y and A2XS(FL)2Y. The cables are triple extruded using proprietary materials on modern catenary line equipment to the latest IEC standards. Waterblocking tape options ensure that should the cable be damaged, repair lengths and associated works are kept to a minimum. The cables are provided as standard with

a high density polyethylene sheath, chosen to give the best compromise between abrasion resistance and flexibility to ensure installation confidence. The range can be customized to meet specific project demands should the need arise

 

CONSTRUCTION:
Conductor
Class 2 copper or aluminum conductor, compacted or segment
strand Milliken to BS EN 60228 (previously BS 6360)
Conductor Screen
Extruded semi-conductive XLPE (Cross-Linked Polyethylene)
Insulation
XLPE (Cross-Linked Polyethylene)
Insulation Screen
Extruded semi-conductive XLPE (Cross-Linked Polyethylene)
Separator
Water swellable semi-conductive tape
Screen
Copper wire screen, with a counter helix of copper tape
Separator
Water swellable tape
Sheath
HDPE (High Density Polyethylene)

 

CONSTRUCTION:
Conductor
Class 2 copper or aluminium conductor, compacted or segment
strand Milliken to BS EN 60228 (previously BS 6360)
Conductor Screen
Extruded semi-conductive XLPE (Cross-Linked Polyethylene)
Insulation
XLPE (Cross-Linked Polyethylene)
Insulation Screen
Extruded semi-conductive XLPE (Cross-Linked Polyethylene)
Separator
Water swellable semi-conductive tape
Screen
Copper wire screen, with a counter helix of copper tape
Separator
Water swellable tape
Sheath
HDPE (High Density Polyethylene)

 

DIMENSIONS
2XS(F)2Y Copper Conductor

NO. OF
CORES
NOMINAL
CROSS
SECTIONAL
AREA
mm²
ELECTRICAL
PROTECTION
mm2
NOMINAL
DIAMETER OF
CONDUCTOR
mm
NOMINAL
THICKNESS OF
INSULATION
mm
NOMINAL
DIAMETER
OVER
INSULATION
mm
NOMINAL
OVERALL
DIAMETER
mm
NOMINAL
WEIGHT
kg/km
MINIMUM
BENDING
RADIUS
(FIXED)
mm
MAXIMAL
FORCE OF
DRAGGING
(CONDUCTOR
PULLING)
kN
1
1
1
1
1
1
1
1
150
185
240
300
400
500
630
800
95
95
95
95
95
95
95
95
14.1
15.7
18
20.3
23
26.5
30.3
36.9
18
17
16
15
15
15
15
15
54.9
54.5
54.8
55.1
57.6
61.3
64.5
71.8
64.5
64.1
64.4
64.7
67.4
71.3
74.8
82.6
4910
5145
5614
6085
7075
8185
9740
11869
970
960
970
1000
1010
1070
1200
1240
7.5
9.2
12
15
20
25
31.5
40


A2XS(F)2Y Aluminium Conductor

NO. OF
CORES
NOMINAL
CROSS
SECTIONAL
AREA
mm²
ELECTRICAL
PROTECTION
mm2
NOMINAL
DIAMETER OF
CONDUCTOR
mm
NOMINAL
THICKNESS OF
INSULATION
mm
NOMINAL
DIAMETER
OVER
INSULATION
mm
NOMINAL
OVERALL
DIAMETER
mm
NOMINAL
WEIGHT
kg/km
MINIMUM
BENDING
RADIUS
(FIXED)
mm
MAXIMAL
FORCE OF
DRAGGING
(CONDUCTOR
PULLING)
kN
1
1
1
1
1
1
1
1
1
1
150
185
240
300
400
500
630
800
1000
1200*
95
95
95
95
95
95
95
95
95
95
14.1
15.7
18
20.3
23
26.5
30.3
36.9
37.9
44
18
17
16
15
15
15
15
15
15
15
54.9
54.5
54.8
55.1
57.6
61.3
64.5
71.8
72.8
78
64.5
64.1
64.4
64.7
67.4
71.3
74.8
82.6
84
90
3995
4026
4156
4263
4746
5287
5908
6925
7409
8010
970
960
970
1000
1010
1070
1200
1240
1260
1350
4.5
5.5
7.2
9
12
15
18.9
24
30
36

 

CONDUCTOR

Class 2 Stranded Conductors for Single Core and Multi-Core Cables

NOMINAL CROSS
SECTIONAL AREA
mm²
MINIMUM NO. OF WIRES IN CONDUCTORMAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
CircularCircular CompactedAnnealed Copper ConductorAluminum or Aluminum
Alloy Conductor
ohms/km
CuAlCuAlPlain Wires
ohms/km

150
185
240
300
400
500
630
800

1000
1200*

37
37
37
61
61
61
91
91

91
/

37
37
37
61
61
61
91
91

91
/

18
30
34
34
53
53
53
53

53
/

15
30
30
30
53
53
53
53

53
/

0.124
0.0991
0.0754
0.0601
0.047
0.0366
0.0283
0.0221

0.0176
/

0.206
0.164
0.125
0.1
0.0778
0.0605
0.0469
0.0367

0.0291
0.0247

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL CHARACTERISTICS

1= cross-bonding of grounding
2= both ends grounded

CONDUCTOR TYPECOPPER CONDUCTORALUMINIUM CONDUCTOR
INSTALLATIONGROUNDAIRGROUNDAIR
METHOD OF
INSTALLATION
Flat SpacedTrefoilFlat SpacedTrefoilFlat SpacedTrefoilFlat SpacedTrefoil
METHOD OF
EARTHING
1212121212121212
NOMINAL CROSS
SECTIONAL AREA
mm²
CURRENT RATINGS
Amps
150
185
240
300
400
500
630
800
1000
1200*
435
490
570
640
720
825
940
1055
-
-
406
448
505
535
595
650
705
755
-
-
410
465
540
610
690
785
890
1000
-
-
406
453
519
580
650
730
810
885
-
-
551
630
740
805
915
1060
1235
1415
-
-
515
574
659
685
775
860
950
1040
-
-
478
546
645
710
820
945
1085
1235
-
-
473
538
628
685
785
895
1010
1130
-
-
335
380
445
495
565
645
740
845
950
1025
325
363
416
445
500
555
610
665
720
755
320
360
420
475
540
620
710
805
900
970
320
358
416
460
525
595
670
745
820
870
431
494
583
625
715
835
975
1130
1295
1420
415
465
541
565
640
725
820
910
1005
1070
373
425
504
550
640
745
865
995
1135
1235
373
423
499
540
625
720
830
940
1055
114

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DE-RATING FACTORS

AMBIENT TEMPERATURE10ºC15ºC20ºC25ºC30ºC35ºC40ºC45ºC50ºC55ºC60ºC65ºC70ºC
In Ground1.071.041.000.960.930.890.850.800.760.710.650.600.53
In Air1.151.121.081.041.000.960.910.870.820.760.710.650.58

Hot Products

APPLICATION: XLPE insulated and halogen-free thermoplastic compound sheathed power and auxiliary ...
RZ1-K LSZH Cable use for where fire, smoke emission and toxic fumes create a potential threat to ...
plain single or multi copper conductor Halogen free sheathed cable NHMH-J and NHMH-O Application ...
Halogen free sheathed cable with improved fire characteristics NHXMH-J type cable Application These ...
Indoor cables for telecommunication J-YY ... Bd As communication cable for permanent installation. ...
Fire-alarm cable J-YY cable as communication cable for permanent installation making out connection ...