Home Companies CN Cable Group Co., Ltd.

Tunneling Special Cables Flexible Cable Rubber Insulation For Energy Supply

CN Cable Group Co., Ltd.
Active Member

Contact Us

[China] country

Address: No.80 Dianchang Road,High-Tech Industrial Zone, Zhengzhou,China

Contact name:Andrea

Inquir Now

CN Cable Group Co., Ltd.

Tunneling Special Cables Flexible Cable Rubber Insulation For Energy Supply

Country/Region china
City & Province zhengzhou henan
Categories Power Cables
InquireNow

Product Details

3GHSSHCH 3.6/6kV and 6/10kV flexible cable for energy supply to MV equipment in tunneling
 
APPLICATION
Flexible cable for energy supply to MV equipment in tunnelling and underground mining applications. Low smoke zero halogen (LSZH) sheathed version. Suitable for indoor and outdoor applications.
 
CONSTRUCTION
Phase Conductor
Class 5 copper conductor according to VDE 0295
(IEC 60228)
Insulation
Rubber compound conductor Type 3GI3 according to
VDE 0207 Part 20
Semi-Conductive Layers
Semi-conductive tape over the conductor and inner and outer
semi-conductive rubber layer on the insulation
Protective Earth Conductor
Individual copper screen
Control Conductor
Class 5 tinned copper according to VDE 0295 (IEC 60228)
Central Filler
Rubber compound on a textile polyester support
First Inner Sheath
LSZH (Low Smoke Zero Halogen) Type M1 according to
EN 50363
Monitoring Conductor
Copper wire screen over the frst inner sheath
Second Inner Sheath
LSZH (Low Smoke Zero Halogen) Type M1 according to EN
50363
Armour
Steel wire braid over the second inner sheath
Outer Sheath
LSZH (Low Smoke Zero Halogen) Type M1 according to EN
50363
CHARACTERISTICS
Voltage Rating (Uo/U)
3.6/6kV
6/10kV
Test Voltage
3.6/6kV: 11kV
6/10kV: 17kV
Maximum Short Circuit Temperature
+250°C
Ambient Temperature
Fixed: -40°C to +80°C
Flexed: +5°C to +80°C
Minimum Bending Radius
Fixed: 6 x overall diameter
Flexed: 10 x overall diameter
Maximum Tensile Load*
15N/mm2
Sheath Colour
Black
 
DIMENSIONS

VOLTAGE
kV
NO. OF CORES
(PHASE + EARTH
+ CONTROL+ÜL)
NOMINAL CROSS SECTIONAL AREA
mm²
CONDUCTOR DIAMETER
mm
MINIMUM OVERALL DIAMETER
mm
MAXIMUM
OVERALL
DIAMETER
mm
NOMINAL
WEIGHT
kg/km
MAXIMUM
TENSILE
LOAD
N
Phase
Conductor
Earth
Conductor
Control
Conductor
3.6/6
3.6/6
3.6/6
3.6/6
3.6/6
3.6/6
3.6/6
6/10
6/10
6/10
6/10
6/10
6/10
6/10
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
3+3+3+ÜL
25
35
50
70
95
120
150
25
35
50
70
95
120
150
25/3E
25/3E
25/3E
35/3E
50/3E
70/3E
70/3E
25/3E
25/3E
25/3E
35/3E
50/3E
70/3E
70/3E
2.5ST
2.5ST
2.5ST
2.5ST
2.5ST
2.5ST
2.5ST
2.5ST
2.5ST
2.5ST
2.5ST
2.5ST
2.5ST
2.5ST
6.1
7.2
8.9
10.6
12.3
13.8
15.5
6.1
7.2
8.9
10.6
12.3
13.8
15.5
47.2
49
52.5
56.1
60.3
63.8
67.2
47.2
49
52.5
56.1
60.3
63.8
67.2
52.1
54
57.8
61.6
66.2
70
73.7
52.7
54.6
58.4
62.2
66.8
70.7
74.4
4120
4570
5300
6370
7600
8990
10130
4160
4610
5340
6410
7640
9030
10170
1125
1575
2250
3150
4275
5400
6750
1125
1575
2250
3150
4275
5400
6750

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
ELECTRICAL CHARACTERISTICS
Current Carrying Capacity

NOMINAL CROSS
SECTIONAL AREA
mm²
LAYING ON
THE FLOOR
Amps
 
FREE IN
AIR
Amps
 
REELED
1 Layer
Amps
2 Layer
Amps
3 Layer
Amps
4 Layer
Amps
5 Layer
Amps
6 Layer
Amps
7 Layer
Amps
25
35
50
70
95
120
150
131
162
202
250
301
352
404
138
170
212
263
316
370
424
105
130
162
200
241
282
323
80
99
123
153
184
215
246
64
79
99
123
147
172
198
55
68
85
105
126
148
170
50
62
77
95
114
134
154
35
44
55
68
81
95
109
29
36
44
55
66
77
89

 
Voltage Drop

NOMINAL CROSS SECTIONAL AREA
mm²
POWER FACTOR
0.70.80.91.0
25
35
50
70
95
120
150
1.29
0.95
0.69
0.51
0.41
0.34
0.29
1.45
1.06
0.77
0.56
0.45
0.36
0.31
1.6
1.16
0.83
0.6
0.47
0.38
0.32
1.71
1.23
0.87
0.61
0.47
0.36
0.29

DE-RATING FACTORS

AMBIENT TEMPERATURE10ºC15ºC20ºC25ºC30ºC35ºC40ºC45ºC50ºC55ºC60ºC65ºC70ºC75ºC80ºC
DE-RATING FACTOR1.151.121.081.041.000.960.910.870.820.760.710.650.580.500.41










































































































































































































































































































































Hot Products

APPLICATION: XLPE insulated and halogen-free thermoplastic compound sheathed power and auxiliary ...
RZ1-K LSZH Cable use for where fire, smoke emission and toxic fumes create a potential threat to ...
plain single or multi copper conductor Halogen free sheathed cable NHMH-J and NHMH-O Application ...
Halogen free sheathed cable with improved fire characteristics NHXMH-J type cable Application These ...
Indoor cables for telecommunication J-YY ... Bd As communication cable for permanent installation. ...
Fire-alarm cable J-YY cable as communication cable for permanent installation making out connection ...