Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

 

 

Shortcut info

 

Product name: glass fuse; rated Voltage: AC 250V; rated current: 5A
Function: slow blow; body Size: 11 x 4mm/ 0. 4' x 0. 15' (LED)
Wire Leads length(each): 27mm/ 1 inch
Color: Clear, Silver Tone; material: glass, alloy

 

___________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________

 

 

Specification

 

A=250V B=125V

Part

No.

Ampere

Rating

Voltage

Rating

Max Voltage

Drop (mv)

I2TMelting

Integral(A2.S)

TBP0250A250mA250V2400.06
TBP0315A315mA250V2200.09
TBP0400A400mA250V2000.2
TBP0500A500mA250V1900.4
TBP0630A630mA250V1801.0
TBP0800A800mA250V1601.9
TBP1100A1A250V1404.2
TBP1125A1.25A250V1308.7
TBP1160A1.6A250V12010.1
TBP1200A2A250V10020.3
TBP1250A2.5A250V10040
TBP1315A3.15A250V10068
TBP1400A4A250V100100
TBP1500A5A250V100133
TBP1630A6.3A250V100172

 

 

Certifications

 

Voltage Rating

Agency

Ampere Range

Agency File Number

250VUR250mA ~ 5AE340427(JDYX)
C-UR250mA ~ 5AE340427( JDYX7)
CQC250mA ~ 5ACQC16012161227
VDE500mA,1A,1.25A,1.6A,2A,2.5A,3.15A,5A40032053
PSE250mA ~ 5 APending
KTL250mA ~ 5 APending

Standards:In accordance with IEC60127-1, IEC60127-3, GB9364.1, GB9364.3.

 

 

Dimension (mm)

 

                                                           

 

 

Operating Characteristics

 

% of Ampere Rating(In)

Blowing Time

210%*In2 min Max
275%*In400 ms~10 s
400%* In150 ms~3s

 

 

Average Time Current Curves

 

 

 

Installation Recommendations

 

Propose installation way as following picture.

 

A.Horizontal installation
B.Vertical installation
C.Vertical installation

 

 

Checking and replacing fuses

 

Procedure

 

Many electrical devices used in eye care have an externally accessible fuse near the electrical cord (Figure 1) that you can check and replace by following these steps.

 

Figure 1

 

  1. Disconnect the device from the electrical system.
  2. Remove the fuse from its holder. In some cases you may need a small screwdriver to unscrew the fuse holder cap.
  3. Look at the fuse wire. If there is a visible gap in the wire or a dark or metallic smear inside the glass then the fuse is blown and needs to be replaced. If you cannot see whether the fuse is blown, follow steps 4 and 5. If the fuse is definitely blown, go to step 6.
     
  4. Set a multimeter (Figure 2) to the resistance or Ω (Ohms) setting.

Figure 2

 

5.Place one of the multimeter leads on one end of the fuse. Place the other lead on the other end of the fuse. If the reading is between 0 and 5 Ω (Ohms), the fuse is good. A higher reading indicates a bad or degraded fuse. A reading of OL (Over Limit) definitely means a blown fuse.

6.If the fuse is blown, replace the fuse with one that is exactly the same (see panel). Make sure to note the fuse amperage and voltage ratings, which should be marked on the fuse itself (Figure 3) or on the panel label near the fuse holder. Additionally, note the size and whether it is a slow-blow or a fast-blow type fuse. If there are no markings on the fuse itself or on the equipment you must consult the device's operating manual.

Figure 3

 

 

General suggestions

 

*Always disconnect equipment from electrical power before removing a fuse; not doing so may result in serious injury.
*Always replace a fuse with an identical type, and never substitute a fuse with foil or another object. This could lead to electrocution and fires.
*Keep enough stock of the fuses used in your clinic or hospital. Store each type in separate containers with a label describing the fuse's voltage and amperage, whether it is a fast-blow or slow-blow type, the size, minimum number needed (the minimum stock level), and the models of equipment that use each type of fuse.
*Check your stock of fuses frequently and order more fuses when it reaches the minimum stock level.
If possible, tape a spare fuse to the equipment so that it is available when needed.

Hot Products

Add-A-Circuit Car Automotive Blade Style ATM ATT ACN APS Low Profile Mini Fuse Holder Fuse Tap in ...
Withstand Inrush CQ24LT 002 6.1x2.6mm Ceramic Time Lag Chip Fuse 2A 350V 6125 For LED Lighting ...
CE Certificated 451 453 Series NANO2 Very Fast-Acting Subminiature Surface Mount Fuse 2410 6125 1A ...
CQ24LF 001 6.1x2.6mm Fast Acting Surface Mount Fuse 2410 350V 1A With Silver Plating Interrupting ...
High Voltage Explosion Proof 10.1x3.1mm 4012 Time Delay Surface Mount Fuse 1A 600VAC 350VDC AOLITTEL ...
0201 0402 0603 0805 1206 1Ω~2.2MΩ ±1% SMD General Purpose LED Chip Resistor 1Ω~22MΩ±5% 1210 1218 ...