Fire Alarm Temperature Detection Equipment Temperature Sensor Thermistor Chip Radial NTC 10KOhm 3470

Country/Region china
City & Province dongguan guangdong
Categories Chargers
InquireNow

Product Details

 

Fire Alarm Temperature Detection Equipment Temperature Sensor Thermistor Chip Radial NTC 10KOhm 3470

 

 

Features

 

Temperature sensor designs according to device of firealarm
Chip of it is Shibaura NTC thermistor
Epoxy coated so it can resist humidity
Good coherence and stability,high humidity and durability
Enjoys a large sale in China, America and Japan

 

__________________________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________

 

 

Dimension (mm)

 

 

Material

 

NOMaterial NameItem/PN
1.ElementR25=10KΩ±1% B25/50=3470K±1%
2.CoatingResin (Black)
3.Lead WireStents

 

 

Electrical Performances

 

NOItemSignTest ConditionsMin.Normal valueMax.Unit
1.Resistance at 25℃R25

Ta=25±0.05℃

PT≦0.1mw

9.910.010.1
2.B ValueB25/503435.334703504.7k
3.Dissipation factorσTa=25±0.5℃≧0.9mW/℃
4.Time constantτTa=25±0.5℃≦15sec
5.Maximum rated powerP/≦25mW
6.Operating temp.range//-40/+125

 

 

Reliability Test

 

NOItemTechnical requirementsTest conditions and method
1.WeldabilitySolder coating area is over 95%Temperature: 260℃±5℃, Time: ≤Sec
2.Resistance To Soldering HeatR25 △R/R≤±3%Tin stove temperature: ≤260±5℃, Immersion depth is ≥9mm distance far away with body, Time: ≤3Sec
3Steady State TemperaturR25 △R/R≤±3%Temperature:40±3℃; Humidity:90-98%, Time:300H
4Temp. cycle testR25 △R/R≤±3%–20±3℃×30min 120±3℃×30min×50 cycles
5.High temperature storageR25 △R/R≤±3%Temperature:120±3℃; Time:300H
6Low temperature storageR25 △R/R≤±3%Temperature:-20℃; Time:300H
7Drop testNo visible damageFree fall into concrete floor from height 1M ,5 cycle.
8Bending testBend 90°binding site wire and epoxy resin.Back and forth 3 times
9Tensile testsFixed resistors at both ends ,Pull: 10±1N, Time: 10±1 Sec

 

 

Resistance Vs. Temperature Table 

 

R-T CONVERSION TABLE
 
R25=10KΩ±1% B25/50=3470K±1%
T(℃)R↓(%)Rmin (KΩ)Rcen (KΩ)Rmax (KΩ)R↑(%)
-40-4.094222.2558231.7438241.46074.193
-39-4.037209.6808218.502227.53114.132
-38-3.98197.8985206.1023214.49484.072
-37-3.924186.8541194.4861202.28944.012
-36-3.868176.4971183.5991190.85663.953
-35-3.813166.7797173.3905180.14243.894
-34-3.757157.6592163.8144170.09773.836
-33-3.703149.095154.8275160.67633.778
-32-3.648141.0496146.3899151.83563.72
-31-3.594133.4886138.4647143.53653.663
-30-3.54126.38131.018135.74273.606
-29-3.487119.7408124.0667128.47133.55
-28-3.434113.4893117.5251121.63223.495
-27-3.381107.601111.3668115.19733.44
-26-3.329102.0526105.5671109.14033.385
-25-3.27796.8223100.103103.43683.33
-24-3.22691.890494.953398.06433.276
-23-3.17487.238190.098193.00173.223
-22-3.12382.847885.518888.22923.169
-21-3.07378.703481.198283.72873.116
-20-3.02274.789777.120379.48313.064
-19-2.97271.102873.280775.48773.012
-18-2.92267.617969.653371.7152.96
-17-2.87364.322666.225168.15122.908
-16-2.82361.205662.983964.78362.857
-15-2.77458.256659.91961.60062.807
-14-2.72655.465557.019758.59122.756
-13-2.67752.82354.276155.74472.706
-12-2.62950.320251.678953.05152.656
-11-2.58147.949449.219850.50272.606
-10-2.53345.702646.890548.08962.557
-9-2.48643.595644.707245.82882.509
-8-2.4441.595242.635343.68442.461
-7-2.39339.695840.66941.65022.413
-6-2.34737.891738.802339.722.365
-5-2.30136.177637.029537.88772.318
-4-2.25534.548735.345636.14822.271
-3-2.20933.000433.745834.49622.224
-2-2.16331.528332.225432.9272.177
-1-2.11830.128430.780331.43612.131
0-2.07328.796529.40630.0192.084
1-2.02627.486528.05528.62652.037
2-1.9826.245226.775427.30821.99
   
   
R-T CONVERSION TABLE
 
R25=10KΩ±1% B25/50=3470K±1%
3-1.93425.068525.562926.05961.943
4-1.88923.952824.413924.87691.897
5-1.84322.894523.324523.75611.851
6-1.79821.890122.29122.69331.805
7-1.75420.936821.310521.68551.759
8-1.70920.031420.379820.72921.714
9-1.66519.171519.496219.82181.67
10-1.62218.354118.656718.961.626
11-1.57817.577417.859318.14181.582
12-1.53516.838717.101217.36421.538
13-1.49216.136216.380616.62541.495
14-1.4515.467515.69515.92291.452
15-1.40714.831115.042815.25481.409
16-1.36614.225214.422114.61921.367
17-1.32413.647813.830914.01411.325
18-1.28213.098113.268213.43851.283
19-1.24112.57412.73212.89011.242
20-1.212.074312.22112.36771.201
21-1.1611.597711.733811.86991.16
22-1.11911.143211.269411.39561.12
23-1.07910.709410.826310.94321.079
24-1.0410.295410.403510.51171.04
25-19.91010.11
26-1.0399.51499.61489.71471.039
27-1.0789.14819.24789.34751.078
28-1.1178.79788.89728.99661.117
29-1.1558.46318.5628.66091.155
30-1.1938.14358.24188.34021.194
31-1.2317.83757.93528.03291.232
32-1.2697.54537.64227.73921.269
33-1.3067.26557.36167.45781.307
34-1.3436.9987.09337.18861.344
35-1.386.7426.83636.93071.381
36-1.4166.49666.58996.68331.418
37-1.4526.2626.35436.44671.454
38-1.4886.03716.12836.21971.491
39-1.5245.82175.91186.00211.527
40-1.565.61515.70415.79331.563
41-1.5955.41735.50515.59311.599
42-1.635.22765.31425.4011.634
43-1.6655.04575.13115.21681.669
44-1.74.87114.95535.03981.705
45-1.7344.70374.78674.871.739
46-1.7684.5434.62484.70691.774
 

 

 

R-T CONVERSION TABLE
 
R25=10KΩ±1% B25/50=3470K±1%
47-1.8024.38884.46934.55011.809
48-1.8364.24074.324.39961.843
49-1.8694.09834.17644.25481.877
50-1.9033.96194.03874.11591.911
51-1.9363.82793.90353.97941.945
52-1.973.69913.77343.84811.979
53-2.0033.57523.64833.72182.013
54-2.0363.45613.52793.60012.047
55-2.073.34133.41193.48292.081
56-2.1023.23093.30033.37012.115
57-2.1353.12453.19273.26132.148
58-2.1683.02223.08923.15662.182
59-2.22.92372.98953.05572.215
60-2.2322.82892.89352.95852.248
61-2.2652.73742.80082.86472.281
62-2.2972.64932.71162.77432.314
63-2.3282.56452.62562.68722.346
64-2.362.48262.54262.60312.379
65-2.3922.40372.46262.5222.411
66-2.4232.32772.38552.44382.443
67-2.4542.25432.3112.36822.476
68-2.4852.18362.23932.29552.508
69-2.5162.11542.172.22512.54
70-2.5472.04952.10312.15722.571
71-2.5781.98612.03872.09182.603
72-2.6081.92491.97642.02852.635
73-2.6391.86561.91621.96732.666
74-2.6691.80861.85821.90832.697
75-2.6991.75361.80221.85142.728
76-2.7291.70031.7481.79622.759
77-2.7591.64891.69571.7432.79
78-2.7891.59921.64511.69152.821
79-2.8181.55141.59641.64192.852
80-2.8481.50511.54921.59392.882
81-2.8771.46021.50351.54732.913
82-2.9061.4171.45941.50242.943
83-2.9351.37531.41691.4592.973
84-2.9641.33481.37561.41693.004
85-2.9931.29581.33581.37633.033
86-3.0221.25751.29671.33643.064
87-3.0511.22041.25881.29773.094
88-3.081.18481.22241.26063.124
89-3.1091.151.18691.22433.154
90-3.1371.11651.15271.18943.184
 

 

 

R-T CONVERSION TABLE
 
R25=10KΩ±1% B25/50=3470K±1%
91-3.1661.0841.11941.15543.214
92-3.1941.05271.08741.12273.244
93-3.2231.02241.05641.0913.273
94-3.2510.9931.02641.06033.303
95-3.2790.96450.99721.03043.332
96-3.3070.9370.9691.00163.362
97-3.3350.91020.94160.97353.391
98-3.3630.88440.91520.94653.42
99-3.3910.85940.88960.92033.449
100-3.4180.83530.86490.8953.478
101-3.4460.81170.84070.87023.507
102-3.4730.78890.81730.84623.536
103-3.50.7670.79480.82313.565
104-3.5280.74570.7730.80083.593
105-3.5550.7250.75170.77893.622
106-3.5820.70490.73110.75783.65
107-3.6090.68550.71120.73743.679
108-3.6360.66660.69180.71743.707
109-3.6620.64840.67310.69823.735
110-3.6890.63080.6550.67963.763
111-3.7150.61380.63750.66173.791
112-3.7420.59710.62030.6443.819
113-3.7680.5810.60380.6273.847
114-3.7940.56540.58770.61053.875
115-3.820.55030.57220.59453.902
116-3.8470.53550.55690.57883.93
117-3.8730.52120.54220.56373.958
118-3.8990.50730.52790.54893.985
119-3.9240.4940.51420.53484.012
120-3.950.48090.50070.52094.04
121-3.9760.46820.48760.50744.067
122-4.0010.45590.47490.49434.094
123-4.0270.4440.46260.48174.121
124-4.0520.43250.45080.46954.148
125-4.0770.42120.43910.45744.175
 
 
Thermistor – Temperature Detection Fire Alarm Example
 
Thermistors serve a crucial role in temperature detection. For example, thermistor temperature detection can be used in fire alarms to detect fires based on a sudden change in temperature. Unlike photoelectric detectors or ionization alarms, thermistors only require heat to activate.
 
 
Photoelectric and Ionization Fire Alarms

The photoelectric detector requires heavy smoke or a smoldering fire to work properly. Heavy smoke from a fire enters a chamber in the alarm with a LED light. The smoke will then deflect light onto a photoelectric sensor, activating the alarm. The complex circuitry and required chamber increases manufacturing price.
Although the ionization method in a fire alarm is effective in alerting those around it in the case of hot blazing fires, it is also sensitive to dust or steam which causes false alarms. units will either be disabled or removed completely by annoyed owners due to so many false alarms.The disabling and removal of the fire alarms increases the risk of bodily harm. The radioactive nature of ionization alarms requires proper disposal when the alarms are no longer working. Just like photoelectric detectors, the circuitry in an alarm utilizing the ionization method requires complex circuitry, making this alarm costly. The most cost effective fire alarm is one utilizing the thermistor method.
 
 
Thermistor Temperature Detection in Fire Alarms

The thermistor method, unlike the previous examples, uses heat detection to activate. The alarm activates once the thermistor detects a high temperature. Thermistor temperature detection doesn’t require smoke to activate and has fewer false alarms. The thermistor uses the ambient temperature of a building and will only activate when that temperature increases exponentially. The thermistor method is reliable in this fire alarm example as there would be few false alarms and a quicker alert rate, but the thermistor method is also versatile.
 
 
Versatility with Thermistor Temperature Detection

Thermistors as temperature detectors are versatile in the fire alarm example because of the many placement options available. Thermistor fire alarms can be placed in
  • areas with high steam, such as used in dairy factories
  • Incineration and oven rooms where smoke usually gathers
  • rooms with high temperatures like welding workshops
  • industrial workplaces with a lot of dust and smoke
With strategic placing, the thermistor method would not cause unnecessary alarms, while still being reliable in the industrial workplace to ensure all employees reach safety when a threat of fire occurs. Thermistors can activate at specific temperatures. The fine tuning allows for even greater versatility in their placement.
 
 
Thermistor Temperature Detection for Homes

Data compiled and published by www.usfa.fema.gov show the numbers on residential fires and their causes from 2009 to 2011. The connections behind outlets in the wall cause about nine percent of all residential fires. Although not a high number comparatively, it is another place a thermistor temperature detection type fire alarm would prove beneficial. The thermistor used for temperature detection is so tiny that an alarm could be manufactured small enough to be placed behind electrical outlets. Should a high temperature occur in the outlet creating a fire danger, the alarm would alert those around to shut the power off or could shut off power automatically.
 

Lower Cost of Thermistor Alarms

Production of a fire alarm utilizing the thermistor temperature detection method is more cost effective because of the simple circuitry and easy construction. The alarms require one part for manufacturing, rather than multiple complex parts. The thermistor doesn’t contain hazardous material, allowing for easy disposal when the alarm is no longer working.
Thermistors used in temperature detection are versatile and cost effective pieces of circuitry. In our example of fire alarms, we have seen that they are more cost effective due to simple circuitry, have fewer false alarms due to their effective detection of temperature and are versatile due to their small size. These thermistors are crucial for temperature detection, not just in fire alarms, but in any piece of machinery that requires temperature detection.

Hot Products

Add-A-Circuit Car Automotive Blade Style ATM ATT ACN APS Low Profile Mini Fuse Holder Fuse Tap in ...
CQ24LF 001 6.1x2.6mm Fast Acting Surface Mount Fuse 2410 350V 1A With Silver Plating Interrupting ...
Withstand Inrush CQ24LT 002 6.1x2.6mm Ceramic Time Lag Chip Fuse 2A 350V 6125 For LED Lighting ...
High Voltage Explosion Proof 10.1x3.1mm 4012 Time Delay Surface Mount Fuse 1A 600VAC 350VDC AOLITTEL ...
CE Certificated 451 453 Series NANO2 Very Fast-Acting Subminiature Surface Mount Fuse 2410 6125 1A ...
0201 0402 0603 0805 1206 1Ω~2.2MΩ ±1% SMD General Purpose LED Chip Resistor 1Ω~22MΩ±5% 1210 1218 ...