Temperature Protection Aupo Thermal Fuse Cutoff TF 125℃ 250V 3A A3-3A-F Plastic Case Thermal Links For Home Appliances

 

 

Description

 

The following product specifications apply to fuses of the A series. The A series consists of thermal cutoff fuses for over-temperature protection. The A series thermal fuses are widely used in various applications such as transformers, adapters, secondary batteries, household appliances, gas water heaters, lighting and other heating equipment.

 

The A-3A-F thermal cutoff fuses are non-resetting single-pole and normally closed devices and provide accurate, reliable protection for high temperature applications against overheating through interrupting electric current. With their metal body and strong leads these fuses offer a sturdy built and high rated currents such as 3 Ampere.

 

 

 

Features

 

• Epoxy sealing material

• Small size, 6.2mm×6.3mmx2.5mm

• Protection against harmful over-temperature in primary and secondary applications.

• Lead-free, RoHS compliant

• Designed according to IEC 60691

 

 

Dimension(mm)

 

 

 

Ordering info

 

Model NORated functioning temp.Fusing-off temperatureHolding temperatureMaximum temp .limitRated currentRated voltage
PN(Tf) (Th)(Tm)(Ir)(Ur)
A0-3A-F84℃82±2℃65℃203℃3A250V
A1-3A-F102℃98±2℃80℃203℃3A250V
A2-3A-F115℃112±3℃95℃203℃3A250V
A3-3A-F125℃120±3℃105℃203℃3A250V
A4-3A-F130℃126±2℃107℃203℃3A250V
A5-3A-F135℃131±3℃115℃203℃3A250V
A7-3A-F138℃135±2℃115℃203℃3A250V
A12-3A-F145℃140±2℃126℃203℃3A250V
A8-3A-F150℃145±3℃128℃203℃3A250V
A16-3A-F160℃155±2℃135℃203℃3A250V

 

RatingsIndicatorDescription
Rated Functioning TemperatureTfThe temperature at which the thermal cutoff fuse changes its state of conductivity and opens the circuit with detection current of <10mA as the only load. The temperature tolerance for UL CSA and VDE standards is +0. -10ºC
Hold TemperatureThThe maximum temperature at which a thermal cutoff can be maintained while conducting rated current for 168 hours without causing a change in the conductivity to open the circuit.
Maximum Temperature LimitTmAt the rated voltage, the temperature the fuse can withstand for 10 minutes at highest temperature rating without change in the conductivity
Rated CurrentIrThe maximum current which the thermal cutoff fuse is able to carry and not affect its electrical characteristics.
Rated VoltageUrThe maximum voltage which the thermal cutoff fuse is able to carry and not affect its electrical characteristics.

 

 

Test Conditions

 

1 Insulation Resistance

 

A .Lead and shell For the thermal fuse body in testing the insulation resistance between wire and plastic shell, should be the first resistance limit pointer adjustment for the position of the 2 m Ω, then use the foil package thermal fuse body shell, then measure the insulation resistance between wire and metal foil.When indicating value of the insulation resistance is greater than 2 m Ω;NG signals does not produce, found the sample is qualified.

 

B. (after disconnecting) between the two lead On heat fusing two fuses, in testing the insulation resistance between the resistance limit pointer adjustment to the first position in the 0.2 M Ω, then measure the heat fusing the insulation resistance between the two leads.When indicating value of the insulation resistance is greater than 0.2 M Ω;NG signals does not produce, found the sample is qualified.Lead and shell For the thermal fuse body in testing the insulation resistance between wire and plastic shell, should be the first resistance limit pointer adjustment for the position of the 2 m Ω, then use the foil package thermal fuse body shell, then measure the insulation resistance between wire and metal foil.When indicating value of the insulation resistance is greater than 2 m Ω;NG signals does not produce, found the sample is qualified.

 

 

2 Dielectric strength

 

A. fuses with the shell On the thermal fuse body between the wire and plastic shell to wear strength test, the fuse body shell with metal foil, and then between the wire and metal foil test voltage of 1500 v (AC), a minute, if you do not see any discharge or breakdown phenomenon is found for qualified. B. (after disconnecting) between the two lead On the thermal fuse body fight between two fuses in strength test, applying test voltage of 500 v (AC) between the two leads, a minute, if you do not see any discharge or breakdown phenomenon is found for qualified.

 

 

Thermal Links Family

 

Hot Products

Add-A-Circuit Car Automotive Blade Style ATM ATT ACN APS Low Profile Mini Fuse Holder Fuse Tap in ...
CQ24LF 001 6.1x2.6mm Fast Acting Surface Mount Fuse 2410 350V 1A With Silver Plating Interrupting ...
Withstand Inrush CQ24LT 002 6.1x2.6mm Ceramic Time Lag Chip Fuse 2A 350V 6125 For LED Lighting ...
High Voltage Explosion Proof 10.1x3.1mm 4012 Time Delay Surface Mount Fuse 1A 600VAC 350VDC AOLITTEL ...
CE Certificated 451 453 Series NANO2 Very Fast-Acting Subminiature Surface Mount Fuse 2410 6125 1A ...
0201 0402 0603 0805 1206 1Ω~2.2MΩ ±1% SMD General Purpose LED Chip Resistor 1Ω~22MΩ±5% 1210 1218 ...