Acid & Alkali Resistant Corrosion Proof Lab Duct Chemical Fume Hood Explosion Proof

1. Product Description 

 

A fume hood (sometimes called a fume cupboard or fume closet) is a type of local ventilation device that is designed to limit exposure to hazardous or toxic fumes, vapors or dusts.

A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height.

Two main types exist, ducted and recirculating (ductless). The principle is the same for both types: air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room. This is used to:

-protect the user from inhaling toxic gases (fume hoods, biosafety cabinets, glove boxes)
-protect the product or experiment (biosafety cabinets, glove boxes)
-protect the environment (recirculating fume hoods, certain biosafety cabinets, and any other type when fitted with appropriate filters in the exhaust airstream)

Secondary functions of these devices may include explosion protection, spill containment, and other functions necessary to the work being done within the device.

 

2. Product Parameters 

 

Model

Parameters

YT-1500AYT-1500BYT-1500CYT-1800AYT-1800BYT-1800C
Size (mm)1500(W)*865(D)*2400(H)1800(W)*1205(D)*2400(H)
Worktop Size (mm)1260(W1)*795(D1)*1100(H1)1560(W1)*795(D1)*1100(H1)
Worktop20+6mm Ceramic20+6mm Ceramic12.7mm Solid Physiochemical Board20+6mm Ceramic20+6mm Ceramic12.7mm Solid Physiochemical Board
Liner5mm Ceramic Fibre5mm Compact Laminate5mm Compact Laminate5mm Ceramic Fibre5mm Compact Laminate5mm Compact Laminate
Diversion StructureBack Absorption
Control SystemTouch-Tone Control Panel (LED Screen)
Input Power220V/32A
Fan PowerLess than 2.8 A
Socket Max. Load5KW
Faucet1 Set
Drainage ModeNatural Fall
StorageDouble-Lock, Corrosion-Resistant, Damp-proof, Multi-layer Solid Wood with Mobile Wheel
ApplicationIndoor No-blast, 0-40 ℃
Application FieldOrganic Chemical Experiment
Face Velocity ControlManual Control
Average Face Velocity0.3-0.5 m/s Exhaust: 720-1200m³/h0.3-0.5 m/s Exhaust:900- 1490m³/h
Face Velocity DeviationLess than 10%
Average IlluminationLess than 500 Lux
NoiseWithin 55 dB
Exhaust AirNo Residue
Safety TestIn Accord with International Standard
ResistanceLess than 70Pa
Add Air FunctionDistinctive Structure (Need Exclusive Add Air System)
Air Flow Control ValveDia. 250mm Flange Type Anti-Corrosion Control ValveDia. 315mm Flange Type Anti-Corrosion Control Valve

 

3. More About the Fume Hood 

 

Fume hoods and other exhaust devices are the single largest energy consumer in a typical laboratory. It is therefore essential to explore options to minimize the energy consumption. When seeking to lower the energy consumption of fume hoods there are, broadly speaking, three approaches.

-Reduce the size of the working sash opening while maintaining a conventional face velocity of 80 - 100 feet /minute
-Reduce the face velocity to 50 - 60 feet/minute while maintaining a generous working opening.
-Implement usage based controls such as VAV so that energy consumption is minimized while the fume hood is not in use.

We supports all these options with our product range which includes restricted bypass hoods for VAV use, High Efficiency hoods that operate at 50-60 feet/minute and the Low Volume model which features a reduced size working opening. We also offers auto lowering sashes in both spring return and motorized versions.

 

Fume Hood Sash Types

We provides fume hoods with a variety of sash configurations. The most common type for bench hoods is the vertically rising sash. This sash travels up and down only and generally provides maximum protection for the operators face when it is used approximately half open. The combination sash is essentially a vertically rising sash frame with smaller inset horizontally sliding panels. In general this should be reserved for operations that require frequent access to the upper portion of the fume hood chamber. Larger floor mount fume hoods can be provided with double hung vertically rising sashes or top hung horizontally sliding panels. Various combinations of the above sashes can be specifically designed to meet your exact needs.

Counter Top Materials
Counter tops can be provided for hoods in either stainless steel (note limitations in liner section) or cast epoxy resin. Epoxy is most commonly selected due to its very broad chemical resistance

 

4. Detailed Photos

 

 

 

 

 

5. Fume Hood Maintenance

 

Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.

• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.

Fume hoods should be certified, at least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies have shown that face velocity is not a good predictor of fume hood leakage.

• Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.

Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from exposure to vapors, aerosols, toxic materials, odorous, and other harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.

 

6. Project Cases

 

 

 

7. FAQ

 

6 Questions to Ask When Buying a Fume Hood:

-Which chemicals will you use within the hood?

-Is a ducted or ductless hood best suited to your needs and available space?

-Where will you place the fume hood in the lab? Consider workflows, access to external exhaust systems, and competing air patterns.

-What size fume hood will best suit your needs? Be sure to consider what (if any) equipment will be enclosed in the hood.

-Are any service fixtures or accessories such as airflow monitors, electrical outlets, water, or gas fixtures required?

-Are base cabinets for acid, solvent, or non-chemical storage required?

Hot Products

Fireproof Explosion Proof Acid & Alkali Resistant Chemical Lab Fume Cupboard Heat Resistant 1. ...
Heat Resistant Acid & Alkali Resistant Chemical Laboratory Duct Fume Hood with Fireproof 1. Product ...
Acid & Alkali Resistant Heat Resistant Chemical Laboratory Duct Fume Hood Explosion Proof Fireproof ...
Acid & Alkali Resistant Heat Resistant Fireproof Chemical Lab Duct Fume Hood Explosion Proof 1. ...
Acid & Alkali Resistant Heat Resistant Fireproof Lab Chemical Duct Fume Cupboard Explosion Proof 1. ...
Fireproof Acid & Alkali Resistant Heat Resistant Chemical Lab Duct Fume Hood Explosion Proof 1. ...