Chengdu Ample Import And Export Co., Ltd. |
|
1. Product Description
A fume hood (sometimes called a fume cupboard or fume closet) is a
type of local ventilation device that is designed to limit exposure
to hazardous or toxic fumes, vapors or dusts.
A fume hood is typically a large piece of equipment enclosing five
sides of a work area, the bottom of which is most commonly located
at a standing work height.
Two main types exist, ducted and recirculating (ductless). The
principle is the same for both types: air is drawn in from the
front (open) side of the cabinet, and either expelled outside the
building or made safe through filtration and fed back into the
room. This is used to:
-protect the user from inhaling toxic gases (fume hoods, biosafety
cabinets, glove boxes)
-protect the product or experiment (biosafety cabinets, glove boxes)
-protect the environment (recirculating fume hoods, certain
biosafety cabinets, and any other type when fitted with appropriate
filters in the exhaust airstream)
Secondary functions of these devices may include explosion
protection, spill containment, and other functions necessary to the
work being done within the device.
2. Product Parameters
Model Parameters | YT-1500A | YT-1500B | YT-1500C | YT-1800A | YT-1800B | YT-1800C |
Size (mm) | 1500(W)*865(D)*2400(H) | 1800(W)*1205(D)*2400(H) | ||||
Worktop Size (mm) | 1260(W1)*795(D1)*1100(H1) | 1560(W1)*795(D1)*1100(H1) | ||||
Worktop | 20+6mm Ceramic | 20+6mm Ceramic | 12.7mm Solid Physiochemical Board | 20+6mm Ceramic | 20+6mm Ceramic | 12.7mm Solid Physiochemical Board |
Liner | 5mm Ceramic Fibre | 5mm Compact Laminate | 5mm Compact Laminate | 5mm Ceramic Fibre | 5mm Compact Laminate | 5mm Compact Laminate |
Diversion Structure | Back Absorption | |||||
Control System | Touch-Tone Control Panel (LED Screen) | |||||
Input Power | 220V/32A | |||||
Fan Power | Less than 2.8 A | |||||
Socket Max. Load | 5KW | |||||
Faucet | 1 Set | |||||
Drainage Mode | Natural Fall | |||||
Storage | Double-Lock, Corrosion-Resistant, Damp-proof, Multi-layer Solid Wood with Mobile Wheel | |||||
Application | Indoor No-blast, 0-40 ℃ | |||||
Application Field | Organic Chemical Experiment | |||||
Face Velocity Control | Manual Control | |||||
Average Face Velocity | 0.3-0.5 m/s Exhaust: 720-1200m³/h | 0.3-0.5 m/s Exhaust:900- 1490m³/h | ||||
Face Velocity Deviation | Less than 10% | |||||
Average Illumination | Less than 500 Lux | |||||
Noise | Within 55 dB | |||||
Exhaust Air | No Residue | |||||
Safety Test | In Accord with International Standard | |||||
Resistance | Less than 70Pa | |||||
Add Air Function | Distinctive Structure (Need Exclusive Add Air System) | |||||
Air Flow Control Valve | Dia. 250mm Flange Type Anti-Corrosion Control Valve | Dia. 315mm Flange Type Anti-Corrosion Control Valve |
3. More About the Fume Hood
Fume hoods and other exhaust devices are the single largest energy consumer in a typical laboratory. It is therefore essential to explore options to minimize the energy consumption. When seeking to lower the energy consumption of fume hoods there are, broadly speaking, three approaches.
-Reduce the size of the working sash opening while maintaining a conventional face velocity of 80 - 100 feet /minute
-Reduce the face velocity to 50 - 60 feet/minute while maintaining a generous working opening.
-Implement usage based controls such as VAV so that energy consumption is minimized while the fume hood is not in use.
We supports all these options with our product range which includes
restricted bypass hoods for VAV use, High Efficiency hoods that
operate at 50-60 feet/minute and the Low Volume model which
features a reduced size working opening. We also offers auto
lowering sashes in both spring return and motorized versions.
Fume Hood Sash Types
We provides fume hoods with a variety of sash configurations. The
most common type for bench hoods is the vertically rising sash.
This sash travels up and down only and generally provides maximum
protection for the operators face when it is used approximately
half open. The combination sash is essentially a vertically rising
sash frame with smaller inset horizontally sliding panels. In
general this should be reserved for operations that require
frequent access to the upper portion of the fume hood chamber.
Larger floor mount fume hoods can be provided with double hung
vertically rising sashes or top hung horizontally sliding panels.
Various combinations of the above sashes can be specifically
designed to meet your exact needs.
Counter Top Materials
Counter tops can be provided for hoods in either stainless steel
(note limitations in liner section) or cast epoxy resin. Epoxy is
most commonly selected due to its very broad chemical resistance
4. Detailed Photos
5. Fume Hood Maintenance
• Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.
• In case of exhaust system failure while using a hood, shut off
all services and accessories and lower the sash completely. Leave
the area immediately.
• Fume hoods should be certified, at least annually, to ensure they
are operating safely. Typical tests include face velocity
measurements, smoke tests and tracer gas containment. Tracer gas
containment tests are especially crucial, as studies have shown
that face velocity is not a good predictor of fume hood leakage.
• Laboratory fume hoods are one of the most important used and
abused hazard control devices. We should understand that the
combined use of safety glasses, protective gloves, laboratory
smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous
exposure.
• Laboratory fume hoods only protect users when they are used
properly and are working correctly. A fume hood is designed to
protect the user and room occupants from exposure to vapors,
aerosols, toxic materials, odorous, and other harmful substances. A
secondary purpose is to serve as a protective shield when working
with potentially explosive or highly reactive materials. This is
accomplished by lowering the hood sash.
6. Project Cases
7. FAQ
6 Questions to Ask When Buying a Fume Hood:
-Which chemicals will you use within the hood?
-Is a ducted or ductless hood best suited to your needs and
available space?
-Where will you place the fume hood in the lab? Consider workflows,
access to external exhaust systems, and competing air patterns.
-What size fume hood will best suit your needs? Be sure to consider
what (if any) equipment will be enclosed in the hood.
-Are any service fixtures or accessories such as airflow monitors,
electrical outlets, water, or gas fixtures required?
-Are base cabinets for acid, solvent, or non-chemical storage
required?