Product Details

 
IEC 60584 Class 1 Thermocouple Grade Wire Type K Type N Type J Used For Thermocouple Construction
 
Shanghai tankii, specializing in producing thermocouple wire, thermocouple cable, thermocouple MI cable.
A typical thermocouple construction consists of a pair of dissimilar metals that are electrically joined together at the sensing point and connected to a voltage measuring instrument at the other end. When one junction is hotter than the other, a thermal “electromotive” force (in millivolts) is produced that is roughly proportional to the difference in temperature between the hot and cold junctions.

 

Tankii Type K thermocouple is composed of a Nickel-10% chromium (+) wire versus a nickel-5% aluminum and silicon (-) wire. This type of thermocouple should only be used in oxidizing or inert atmospheres with a service temperature range between -200°C and 1260°C (-330°F to 2300°F). They are most widely used at temperatures above 540'C (1000"F) due to superior oxidation resistance in comparison to Types E, T, or J. There are some conditions which should be avoided when using Type K thermocouples. Vacuum applications should not use Type K due to vaporization of chromium in the positive element. Tankii Type K thermocouples should not be used in Sulfurous environments since both elements will rapidly corrode and the negative element will eventually fail mechanically due to becoming brittle. Reducing atmospheres should also be avoided. Low oxygen levels can cause the Green-Rot phenomenon in which the chromium in the elements starts to oxidize causing large negative drifts in calibration.

 

IEC 60584 Class 1 Thermocouple Grade Wire Type K Type N Type J Used For Thermocouple Construction
 
Characteristics:
The thermocouple wires have excellent performance and are extensively used in the temperature measurement and control in different fields, such as metallurgy, chemical industry, petroleum industry, machinery-electric industry, energy industry, agriculture and military industry.
 

Tankii products conform to the standards of IEC584 -1and IEC-2.

 
Tankii Thermocouple strips, thermocouple connectors are available.
Tankii thermocouple grade extension wire can be supplied as per your request.
Tankii KX, JX, TX KC, RC,EX wire with class 1 and 2 are available.
 
Application Industry of Tankii thermocouple wire:
 
1. Aerospace and Composites
2. Aluminum industry
3. Food and Pharmaceutical
4. Forgings
5. Glass, Ceramics, Clay Tiles, Bricks
6. Heat Treating
7. Petroleum, Downhole Oil & Gas
8. Sensor Manufacturing
9. Steel industry
10. Utilities Power Generation
 
Used for thermocouples:
1. Thermocouple assembly
2. Bayonet Mount Thermocouples
3.Thermocouples With Plug
4. Thermocouple With Connection Head
5. Armored Thermocouple
6.Handheld Thermocouple
7. High-Temperature Thermocouple
8.Surface Mount Thermocouple
9. Transition Joint Thermocouple
10. Bare Lead Thermocouple
11. Overbraided Thermocouple
12. Multi-Point Thermocouple
13. Autoclave Thermocouple
14. Magnet Mount Thermocouple
15. Replacement Thermocouple
16. Spring Loaded Thermocouple
17. Bearing Thermocouple Sensor
18.Tube Skin/Weld Pad Thermocouple
19. Penetration Thermocouple
20.Screw In Thermocouple
 
 
IEC 60584 Class 1 Thermocouple Grade Wire Type K Type N Type J Used For Thermocouple Construction
 
Tankii Thermocouple Type and Temperature Range

Thermocouple type and index
 

Measurement Range

Type
 

Index
 

 
PtRh30-PtRh6

B600~1700

 
PtRh13-Pt

R0~1600

 
PtRh10-Pt

S0~1600

 
NiCr-NiSi

K-200~1300

 
NiCr-CuNi (constantan)

E-200~900

 
Fe-CuNi (constantan)

J-40~750

 
Cu-CuNi (constantan)

T-200~350

 
NiCrSi-NiSi

N-200~1300
 

The allowable grade and Tolerance are obtained at 0℃

Thermocouple
Type

Grade

Temperature range

Allowable Tolerance /℃
Type B600~1700±0.25% t
600~800±4
800~1700±0.5%t
Type R(S)0~1100±1
1100~1600±[1+(t-1100) ×0.3%]
0~600±1.5
600~1600±0.25% t
Type K and Type N-40~1100±1.5℃ or ±0.4%t
-40~1300±2.5℃ or ±0.75%t
-200~40±2.5℃ or ±1.5%t
Type E-40~1100±1.5℃ or ±0.4%t
-40~1300±2.5℃ or ±0.75%t
-200~40±2.5℃ or ±1.5%t
Type J-40~750±1.5℃ or ±0.4%t
-40~750±2.5℃ or ±0.75%t
Type T-40~350±0.5℃ or ±0.4%t
-40~350±1.0℃ or ±0.75%t
-200~40±1.0℃ or ±1.5%t

 
DIN250 spool: 17~18kg
 
 

 Delivery and Packing of thermocouple wire:
 
1. Packaging Details : DIN spools with plastic film wrapped and carton package. 
 
2. Leading time : 5 - 20 days, as the order quantity of thermocouple wire.
 
3. Delivery: By express, air, sea as per thermocouple wire qty
 
 
IEC 60584 Class 1 Thermocouple Grade Wire Type K Type N Type J Used For Thermocouple Construction
 
Welcome to call me or email to me for more information on K type thermocouple wire, Thermocouple stranded wire , thermocouple flat wire, thermocouple strip.

Hot Products

1.6mm 0Cr21Al4 FeCrAl Alloy High Resistance Electric Resistance Heating Wire Fe-Cr-Al alloy has the ...
17 SWG 0Cr21Al4/ 0Cr19Al3 Bright Surface High Temperature Heating Wire for Electric Heating Elements ...
Customized Size 0Cr21Al4 FeCrAl 1.4MM-1.6MM Wire Acid Wash Soft Alloy Wire for Redrawing Alloy ...
1.6mm Cr21Al4 Fecral Alloy Wire 0Cr19Al3 FeCeAl Alloy 1.4mm Electric Heating Wire/ Rod Wire Acid ...
High Temperature Heating Resistance Wire Kantha A1 Wire Long Life Sweden Wire for Heating Resistor ...
Cr22Al4.5Fe FeCrAl Alloy Flat /Round Bar With Good Surface Used For Electrical Heating Elements ...