Hangzhou Union Industrial Gas-Equipment Co., Ltd. |
|
Cryogenic Liquid Nitrogen Generation Plant , Air Separation Equipment For Medical
Quick Details:
Condition: new
Place of origin: China(mainland)
Brand name: UIG
Model number: KDN,KLN,KDON SERIES
Production capacity:50-2000 m3/hour
Power :60-1000 KW
Voltage:380v,400V,440V
Certification: ISO 9001:2000
Warranty:1 year
Life:20 years with proper maintenance
After-sales service provided: Engineers available to service plants
overseas
Usage: Industrial and medical (oxygen, liquid oxygen, nitrogen,
liquid nitrogen)
UIG Air separation plants are designed for a vast range of
capacities and products summarized below: FOR OXYGEN 99.7 % AND
NITROGEN 99.999%
Specifications:
The main technical specifications of liquid series ASPs
Model contents | KLN- | KLN- | KDON- 100Y/100Y | KDON- 200/200Y | KDON- 300Y/300Y | KDON- 500Y/500Y | KDON- 800Y/800Y | KDON- 1000Y1000Y | |
Lo2 flow | L/h | -- | -- | 100 | 200 | 300 | 500 | 800 | 1000 |
Lo2 purity | %(o2) | -- | -- | 99.6 | 99.6 | 99.6 | 99.6 | 99.6 | 99.6 |
Lox pressure | Mpa | -- | -- | ~0.03 | ~0.03 | ~0.25 | ~0.25 | ~0.25 | ~0.25 |
LN2 flow | L/h | 8L/h | 30L/h | Or 100 | Or 200 | Or 300 | 500 | Or 800 | 1000 |
LN2 purity | %(N2) | 99.9 | 99.9 | 99.999 | 99.999 | 99.999 | 99.999 | 99.999 | 99.999 |
LN2 pressure | Mpa | Ordinary pressure | Ordinary pressure | ~0.025 | ~0.025 | ~0.4 | ~0.4 | ~0.4 | ~0.4 |
Start-up time | h | 1 | 2 | 5-8 | 8-12 | -16 | -22 | -20 | -26 |
Operating period | year | -- | -- | ≥2 | ≥2 | ≥2 | ≥2 | ≥2 | ≥2 |
Description:
Raw air is sucked from atmosphere. After removing of the mechanical
impurity by air filter, it goes into the screw air compressor to be
compressed to 1.0Mpa. After being cooled and separated from the
water drops, it goes to the air precooler to be cooled to about 8
.0℃. It is separated from water drops through water separator for
removal of saturated water, carbon dioxide and some hydrocarbon
such as acetylene.
Purified air is cooled by the counter flow in the main heat
exchanger to saturated tempt., and part of them flows to the
rectifification column after being liquefied. After
rectifying, the liquid air is sucked from the bottom of the column
and cooled in subcooler and throttled to condenser-evaporator to
evaporate as cold resource. The nitrogen in the top of the column
is evaporated to condensation by liquid air. Most of the condensed
liquid is used as reflux, the rest of them flow to the liquid
storage tank to discharge regularly to the liquid storage tank out
of the column.
To meet different demands from customers, different processes
like air cycle process ,nitrogen cycle process, high and low
temperature booster turbine expanding processor low temperature
refrigerating process etc. are adopted to reduce the power
consumption. In order to achieve stable and reliable operating of
plant, PLC control system or DCS control system are recommended.
Applications:
We have supplied to many countries (Russia, Kazakhstan, Tajikistan,
India, Bangladesh, Thailand, Philippines, North Korea, Mongolia,
Equatorial Guinea, Botswana, Zambia, Angola, Tanzania) .
Competitive Advantage:
The design, selection of material, manufacture, inspection, and test must be in accordance with the state standard and enterprise specification and factory codes .
Quality certificate, inspection and test and records will be provided by the manufactory(quality certificate for pressure vessel will be given by pressure vessel supervision department).
Cryogenic air separation unit,Cryogenic nitrogen machine,Cryogenic liquid nitrogen plants,Cryogenic air separation equipment,Cryogenic air separation plant,Cryogenic nitrogen equipment