Home Companies SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD.

Deep Cycle UPS AGM Front Terminal 12v 150ah Battery For Solar Power System

SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD.
Active Member

Contact Us

[China] country

Address: No.188 Chunxu Road ,Economic Development Zon, Kunshan City, Suzhou, Jiangsu Province, China.

Contact name:Roger Ning

Inquir Now

SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD.

Deep Cycle UPS AGM Front Terminal 12v 150ah Battery For Solar Power System

Country/Region china
City & Province suzhou jiangsu
Categories Batteries
InquireNow

Product Details

Deep Cycle UPS AGM Front Terminal 12v 150ah Battery for Solar Power System

 

FOBERRIA FT series is specially designed for telecom use with 12 years design life in folat service.

 

By adopting a new AGM separator and centralised venting system, the battery can be installed in any position while maintaining high reliability.

 

The demensions of the FT series is designed for 19″ and 23″ cabinet installation. It’s suitable for UPS/EPS

 

>Advantages

 

1. Battery can be installed in any position. Easy instalation and handling.

 

2. Design for telecom with more than 12years design life.

 

3. High purity lead-tin alloy, reduce battery self discharge rate and increase battery service life.

 

4. ABS battery case made by LG raw material to increase battery service life.

 

5. Heat sealing technique instead of glue sealing to increase the tightness and stability of battery.

 

6. TTP technique not only reduce internal resistance and material cost but also increase battery life.

 

7. Conduct four large current discharge texting before package to insure battery quality.

 

8. Full charge before delivery. Buy and use it directly.

 

 

 

 
>Specification
Cells Per Unit6
Voltage Per Unit12
Capacity

100Ah @10hr-rate to 1.80V per

cell @ 25℃

150Ah @10hr-rate to 1.80V per

cell @ 25℃

200Ah @10hr-rate to 1.80V per

cell @ 25℃

Weight31.0KG43.5KG61.0KG

Max.

Discharge Current

1000A(5 sec)1500A(5 sec)1000A(5 sec)
Internal ResistanceApprox. 5.5mΩApprox. 5.0 mΩApprox. 4.5 mΩ
Recommended Maximum Charging Current Limit

 

30A

 

45A

60A
Operating Temperature RangeDischarge: -20℃~60℃ Charge:0℃~50℃ Storage:-20℃~60℃
Normal Operating Temperature Range25℃ ± 5 ℃
Float charging Voltage13.6 to 13.8V DC/unit Average at 25℃
Equalization and Cycle Service14.4to 14.6V DC/unit Average at 25℃
Self DischargeFront triminal batteries can be stored for more than 6 months at 25℃. Self-discharge ratio less than 3% per month at 25℃. Please charge batteries before using.
Size410*109*293MM550*110*290MM550*125*317MM
 
>Structure and composition
 
ComponentPositive plateNegative plateContainerCoverSeparatorElectrolyteSafety valveTerminal
Raw materialLead dioxideLeadABSABSAGMSulfuric acidRubberCopper
 
>Constant Current Discharge Characteristics(A,25ºC)
 
F.V/Time10min15min30min60min2h3h4h5h8h10h20h
9.6V25419611771.943.831.225.221.514.812.26.47
9.9V24619111570.943.631.025.121.414.712.26.46
10.2V23618411169.143.230.824.921.314.612.26.44
10.5V22617810867.642.630.624.721.114.512.16.40
10.8V21316810465.541.529.724.020.514.112.06.36

 

 

>Constant Power Discharge Characteristics(Watt,25ºC)

 

 

F.V/Time10min15min30min60min2h3h4h5h8h10h20h
9.60V27412147131382050836729725517614677.7
9.90V26582096128680850536529525317514677.5
10.2V25492017124778750036229325117414577.3
10.5V24391950121777149336029125017214476.9
10.8V23021847117274748034928224216714376.3
 
 
>Discharge diagram
 
>Application
① Solar and Wind System
② UPS
③ Electronic Apparatus and Equipment
④ Alarm and Security System
⑤ Communication Power Supply
⑥ DC Power Supply
⑦ Emergency Lighting
⑧ Backup Power for Testing and Measuring Instrument
⑨ Telecommunication System
Fire Alarm and Security System
 

>Warning

Replacement of battery shall be performed as per following order. If failed, it may cause fire and explosion. Remove cable from negative terminal first.Connect cable to negative terminal last.

• When connect cable to battery, make sure not to get changed post of +and -. It may cause the damage of electronic components or fire.

• When ueing the battery ,handle with care,sulfuric acid may cause blindness or severe burn.

>Caution

When moving battery, be careful not to drop the battery , which is heavy, Do not shake the battery with handle, if there is the handle, It may cause the injury.

• Do not shore the battery at the following places. High temperature and humidity. Being exposed to rain,snow, direct sunshine.

 
>Production process
 
>FAQ
 
Q1: How to choose the right battery?

A1: Tell us your demand, then our sales will recommend a suitable battery for you.

Q2. Do you have any MOQ limit?

A2: Yes, we have MOQ for mass production, it depends on the different model numbers. 50-500pcs sample order is available.
 
for sample checking is available.

Q3. Is it OK to print my logo on the product?
A3: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.

Q4: How to solve the technical problem?

A4: 24 hours after-service consultancy just for you and to make your problem to solve easily.

Q5:. What certificate your company have?

A5: ISO 9001, ISO 14001, OHSAS 18001, CE, UL, IEC 61427 test report, Patent for gel technology and other Chinese honor.

Q6. What is your warranty time for VRLA battery ?

A6: It depends on battery capacity, depth of discharge, and battery usage. Please kindly contact us for accurate information based on detailed requirements.

Q7. Why battery has different capacity at different hour rate?

A7: The capacity of a battery, in Ahs, is a dynamic number that is dependent on the discharge current.
 
For example, a battery that is discharged at 10A will give you more capacity than a battery that is discharged at 100A.
 
With the 20-hr rate, the battery is able to deliver more Ahs than with the 2-hr rate because the 20-hr rate uses a lower discharge current than the 2-hr rate.

Q8. Are you a battery manufacturer, and do you produce the plate by yourself ?

A8: Yes, we are a professional battery manufacture in Fujian Province, China. And we produce plates by ourselves.

Q9. How to proceed with an order?

A9. Firstly let us know your requirements or application. Secondly, We quote according to your requirements or our suggestions.

Thirdly customer confirms the samples and places a deposit for formal order.

Fourthly We arrange the production.

Q10: How about the delivery time?

A10: About 7 days for stock products, around 20 days for half container products, 30 days for 20ft full container products.
 
 
 
 

Hot Products

Factory sealed lead acid battery maintenance 12V 90ah 100ah For back up power System > This SLA ...
Long Life small rechargeable agm battery 4v0.4ah for Toy Use > 4V0.4 lead acid battery Specification ...
Wholesale Motorcycle Parts 12V 4ah Ytx5l-BS, Ytz6s Motorcycle Battery Wholesale Motorcycle Parts ...
Foberria Motorcycle Parts YTX5L-BS Maintenance Free Motorcycle Battery Primary competitive ...
>Product Description FBR Maintenance Free AGM / VRLA battery are constructed with lead alloy and ...
>Product Description FBR Maintenance Free AGM / VRLA battery are constructed with lead alloy and ...