Home Companies SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD.

Black sealed rechargeable lead acid battery 6v 4ah 20hr UPS Lead Acid Battery

SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD.
Active Member

Contact Us

[China] country

Address: No.188 Chunxu Road ,Economic Development Zon, Kunshan City, Suzhou, Jiangsu Province, China.

Contact name:Roger Ning

Inquir Now

SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD.

Black sealed rechargeable lead acid battery 6v 4ah 20hr UPS Lead Acid Battery

Country/Region china
City & Province suzhou jiangsu
Categories Batteries
InquireNow

Product Details

Black sealed rechargeable lead acid battery 6v 4ah 20hr UPS Lead Acid Battery

 

 

> Primary competitive advantages of UPS Lead Acid Battery

 

1. 100% Pre-delivery inspection to ensure stable quality and reliable performance;
2. Pb-Ca grid alloy battery plate, low water loss, and stable quality low self-discharge rate;
3. Low internal resistance, good high rate discharge performance;
4. Excellence high-and-low temperature performance, working temperature ranging from -25°C to 50°C;
5. Design float service life: 5-7 years.

 

> Specification(FBR6-4.5)
 
Battery Model No. FBR6-4.5
Nominal Voltage 6V
Capacity20HR(5.25V)4.5Ah
(25ºC)10HR(5.25V)4.2Ah
 1HR(4.80V)2.95Ah
DimensionLength42±1mm
Width48±1mm
Height102±1mm
Total height108±1mm
Approx. Weight0.5kg±5%
Terminal typeF1
Internal resistance(Fully charged,25ºC)Approx 16
Capacity affected by40ºC102%
Temperature(20HR)25ºC100%
0ºC85%
-15ºC65%
Self-discharge(25ºC)3monthRemaining Capacity:91%
6monthRemaining Capacity:82%
12monthRemaining Capacity:65%
Nominal operating temperature25ºC±3ºC(77ºF±5ºF)
OperatingDischarge-15ºC-50ºC(5ºF-122ºF)
temperature rangeCharge-10ºC-50ºC(14ºF-122ºF)
 Storage-20ºC-50ºC(-4ºF-122ºF)
Float charging voltage
(25ºC)
4.54 to 4.6V
Temperature compensation:-18mV/ºC
Cyclic charging voltage
(25ºC)
4.84 to 5.0V
Temperature compensation:-30mV/ºC
Max charging current1.35A
Max discharging current67.5A(5sec.)
Designed floating life(20ºC)5years
 
 
>Structure and composition
 
ComponentPositive plateNegative plateContainerCoverSeparatorElectrolyteSafety valveTerminal
Raw materialLead dioxideLeadABSABSAGMSulfuric acidRubberCopper
 
>Constant Current Discharge Characteristics(A,25ºC)
 
F.V/Time10min15min30min60min2h3h4h5h8h10h20h
9.6V26220212174.243.831.225.221.514.812.26.47
9.9V2541971187343.63125.121.414.712.26.46
10.2V24319011571.243.230.824.921.314.612.26.44
10.5V23318311269.742.630.624.721.114.512.16.4
10.8V22017310867.641.529.72420.514.1126.36

 

 

>Constant Power Discharge Characteristics(Watt,25ºC)

 

F.V/Time10min15min30min60min2h3h4h5h8h10h20h
9.60V28252214135384550836729725517614677.7
9.90V27412160132683350536529525317514677.5
10.2V26282081128581250036229325117414577.3
10.5V25142010125479549336029125017214476.9
10.8V23731904120877048034928224216714376.3
 
 
>Discharge diagram
 
>Application

 

 
>Workshop scene
>Daily maintenance and operation

 

Discharge

 

1.Do not let the terminal voltage drop below the terminal voltage;

 

2.Do not leave the battery in a discharged condition. Recharge it immediately. Also when the battery has been over discharged by mistake,

 

recharge it immediately;

 

3.The maximum permissible discharge current 6C amps discharge for 5 seconds or less, do not exceed this value,

 

otherwise it may damage the battery.

 

Charge

 

1.Float charge


The floating charge voltage should remain constant;

 

The effects of too high or too low a floating charge voltage is as follows:


Too high for extended period (overcharge): it may shorten battery life


Too low for extended period (undercharge):

 

it may not meet load or cause variances in battery voltage that will decrease the capacity of battery pack and shorten their life.

 

2.Recovery charge

 

When resuming charging, the initial current should be limited to 0.1C-0.3CA;

 

3.Temperature compensation


When the temperature deviates from 25℃, please modify the voltage as 3mv/cell fo every 1C deviation.

 

3.The equalizing charge


The equalizing charge voltage is 2.30 - 2.35V/cell.

 

4.Cautions during charge


(a)If the charge current exceeds 0.05CA at the final stage of charge, the storage batter may be permanently damaged in appearance and life.

 

Pay special.attention to charging voltage.


(b)The battery charger should be the one that can provide automatic constant voltage with drooping characteristics, if other types will be used,

 

please contact us before applied.

 

 

STORAGE

 

1.When you wish to store the battery, battery should be stored without charger and load at dry location with low temperature.
     

2.If batteries are stored for a long period, give a supplementary charge before use.

 

 

 

 

Hot Products

Factory sealed lead acid battery maintenance 12V 90ah 100ah For back up power System > This SLA ...
Long Life small rechargeable agm battery 4v0.4ah for Toy Use > 4V0.4 lead acid battery Specification ...
Wholesale Motorcycle Parts 12V 4ah Ytx5l-BS, Ytz6s Motorcycle Battery Wholesale Motorcycle Parts ...
Foberria Motorcycle Parts YTX5L-BS Maintenance Free Motorcycle Battery Primary competitive ...
>Product Description FBR Maintenance Free AGM / VRLA battery are constructed with lead alloy and ...
>Product Description FBR Maintenance Free AGM / VRLA battery are constructed with lead alloy and ...