Wenzhou Ace Machienry Co., LTD |
|
Structure and working principle
Bag type filter is a pressure filtration device ,which is mainly
consists of filtration cylinder,cylinder cover and fast open
structure,stainless steel strengthen filtration bag,etc.when
filtrate flows from side entrance of filter shell into the pipe
bag,The bag itself is installed inside the enhanced basket ,liquid
penetrates bag with required fineness grade that can be provided
with qualified filtrate,impurity particles were bag intercept.It is
very easy to replace the filtration bags,there is hardly no
material to be consumed.
Main advantages
Small probability for side-bag leakage , which effectively
guarantee the filtering quality.
Bag type filter can bear greater working pressure, it is of small
pressure loss,low operation cost and obvious energy saving .
Accuracy of filtration bag increased continuously, it could reach
0.5 μm at most.
Bag type filter large handling capacity, small volume, containing a
large quantity of pollutants.
Based on the working principle and structure of Bag type filtering
system,which is convenient to replace the filter bag and without
cleaning,and time saving and labor saving.
Filtration bag could be use repeated after cleaning to save cost.
Bag filter application scope is broad, with flexible operation and
multiple installation .
Application
Bag filters systems are applied in various industries solutions.
Treated liquids include: milk products, paint, lime, beer,
chemicals, mineral water, hot solvent, latex, inks, sugar water,
juice, etc.
To customers
What kind of water you want to treat?
What flow rate you want to treat per hour?
Do you have other specific requirements of bag filters?
1.Main tanks, vessels and machines will be packaged with painted steel frames.
2.All spare parts, accessories and fittings will be packaged with
painted steel box.
3.All items wrapped with soft package for protection.
4.Standard shipping containers will be used for general purpose.
5.All equipments will be loaded into containers according to exact
container layout drawings.
6.After loaded into containers, all equipments will be well fixed
to the containers.
Model | Bag Qty | Filtering area (m) | Max flow (t/h) | Inlet/ outlet connection | Working pressure (Mpa) | Housing Dia. (mm) | Overal heigh (mm) | Housing height (mm) |
JXB2 | 2 | 1 | 70 | DN50 | 0.5 | 456 | 1572 | 1144 |
JXB3 | 3 | 1.5 | 105 | DN80 | 0.5 | 508 | 1592 | 1190 |
JXB4 | 4 | 2 | 140 | DN100 | 0.5 | 558 | 1632 | 1244 |
JXB5 | 5 | 2.5 | 175 | DN150 | 0.5 | 608 | 1788 | 1254 |
JXB6 | 6 | 3 | 210 | DN150 | 0.5 | 658 | 1854 | 1300 |
JXB7 | 7 | 3.5 | 245 | DN150 | 0.5 | 710 | 1875 | 1340 |
JXB8 | 8 | 4 | 280 | DN150 | 0.5 | 760 | 1922 | 1404 |
JXB10 | 10 | 5 | 350 | DN200 | 0.5 | 910 | 2004 | 1430 |
JXB12 | 12 | 6 | 420 | DN200 | 0.5 | 962 | 2064 | 1460 |
JXB14 | 14 | 7 | 490 | DN200 | 0.5 | 1012 | 2124 | 1490 |
JXB16 | 16 | 8 | 560 | DN250 | 0.5 | 1112 | 2146 | 1512 |
JXB18 | 18 | 9 | 630 | DN250 | 0.5 | 1162 | 2225 | 1595 |
JXB20 | 20 | 10 | 700 | DN250 | 0.5 | 1212 | 2280 | 1640 |
JXB22 | 22 | 11 | 770 | DN250 | 0.5 | 1366 | 2320 | 1694 |
JXB24 | 24 | 12 | 840 | DN300 | 0.5 | 1416 | 2358 | 1748 |