Home Companies GANDO INTERNATIONAL (HONGKONG) LIMITED

400KW AC Variable Voltage Variable Frequency Inverter Drives for Water Pump

GANDO INTERNATIONAL (HONGKONG) LIMITED
Active Member

Contact Us

Address: 701 of NO.69, xilinxili, siming, xiamen, China

Phone: 86-013-2436807

Contact name:

Inquir Now

GANDO INTERNATIONAL (HONGKONG) LIMITED

400KW AC Variable Voltage Variable Frequency Inverter Drives for Water Pump

City & Province xiamen fujian
InquireNow

Product Details

400KW AC Variable Voltage Variable Frequency Inverter Drives for Water Pump

 

A pump is a machine or device for raising, transferring, or compressing fluids. Pumps represent the largest single use of power in industry (31%) by motor driven equipment. Process variables, including pressure and flow of gases and liquids, have long been regulated using mechanical clutches, throttles, and adjustable inlet guide vanes. Pumps often operate as a variable torque load, a load that increases as the speed increases. These mechanisms waste energy, require frequent maintenance, and provide inaccurate control.

Pumps have two main categories:

1. Positive displacement pumps force a fixed volume of fluid from inlet to discharge with each stroke or rotation. (e.g., reciprocating, rotary, or screw type pumps)

2. Centrifugal pumps are the biggest class of pumps, which use the fluid's own momentum to build up pressure or head. Centrifugal pumps use centrifugal and hydrodynamic forces to create pressure that moves the fluid from inlet to discharge.

Pumps can also be classified by principle of operation and drive requirements. 

  • Principle of Operation Application Served
  • Materials of Construction
  • Liquid Being Pumped
  • Shaft Orientation (Vertical, Horizontal)
  • Number of Stages
  • SuctionPortArrangement

 

Application Challenges

· Reduce energy costs
Motors use less energy as speed is reduced.

· Reduce demand charges
Drives reduce motor starting current 8-10 times.

· Variable and constant torque load characteristics,  depending on pump type.

· The motor may spin backwards due to pump backpressure when stopped.

· Control of pressure and flow is desired.

· High reliability.

· Wide horsepower range for different pump sizes.

· Environmentally friendly (harmonic standards).

· Network communications.

Prevention of water hammer,  pipe stress,  valve,  and pump seals and cavitation prevention.

 

Features of P5 series cooling tower Water Pump application

Features

Benefits

Dual digital tube

Double lines of LED display, monitoring 2 kinds of information meantime, like frequency, current, voltage, speed and PID data.

Smart restart

Instant power off continue running and speed tracking

S curve acceleration/deceleration mode

S curve acceleration/deceleration can reduce impact to the machine at start/stop time, and suitable for the start/stop process for loads of handling and transmission categories.

Terminal control

Multiple control terminal,  6 DI,  4 DO,  2 AI,  4 AO,  RS-485 support Modbus

 

Power range of P5 VFD

Voltage: 3 phase 380VAC(323VAC – 440VAC)

Power: 18.5kw/25HP – 400kw/535HP

 

Specification of P5 VFD

Item

Specification

Input frequency

50/60Hz

Output frequency

0-120Hz

Overload current

120% rated current 1min.,  130% 6 sec.

Control mode

V/F control

Brake torque

125% with additional brake resistor

Set frequency resolution

digital  command  0.01Hz; 

analogue  command  0.1Hz/60Hz

Voltage/Frequency feature

34 fixed V/F features selectable,  any V/F features can be set

Running Mode 

Keyboard,  control terminal,  RS485 

Output Voltage self-adjustment 

When AVR function is enabled, the input voltage changes, while the output voltage almost remains unchanged

Frequency setting signal

0-10V,  0-5V,  4-20mA,  0-20mA

Protection function

Over voltage, under voltage, current limit, over current, overload, electronic thermal relay, overheat, over voltage stalling, data protection, under load precaution, loaded short circuit

Enclosure

IP10

Cooling mode

forced air cooling

Vibration

Less than 0.5g 

Ambient temperature / Humidity

-10 Degrees~+40 Degrees / 20~90%Rh (no condensation)

 

Tips:

A variable-frequency drive (VFD) is a system for controlling the rotational speed of an alternating current (AC) electric motor by controlling the frequency of the electrical power supplied to the motor. A variable frequency drive is a specific type of adjustable-speed drive. Variable-frequency drives are also known as adjustable-frequency drives (AFD), variable-speed drives (VSD), AC drives, microdrives or inverter drives. Since the voltage is varied along with frequency, these are sometimes also called VVVF (variable voltage variable frequency) drives.

Hot Products

400VAC Variable Speed AC Motor Inverter Drives for Compressor A compressor is a mechanical device ...
1000kw / 1250HP AC Variable Frequency Inverter Drives for Metalforming Metalforming is the process ...
22kw – 1000kw Variable Frequency AC Inverter Drives for Conveyor Conveyors are used in a broad range ...
400V Variable Frequency AC VFD Drives for Decanter Centrifuge Decanter centrifuges are used to ...
Variable Frequency AC Drives Inverter with Voltage 400VAC for Mixer Mixers are used in a wide range ...
AC Variable Frequency Inverter Drives VFD for Screw Feeder 400V Screw feeders are used in various ...