Home Companies Huge Technology Automation Co.,Ltd

X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement

Huge Technology Automation Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Unit 1602, Top Plaza, No.2 Lujiang Road, Siming District, Xiamen Fujian China

Contact name:Candy Wang

Inquir Now

Huge Technology Automation Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement

Country/Region china
City & Province xiamen fujian
Categories Chargers
InquireNow

Product Details

X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement

 

 

MATERIAL NUMBER:

X20AT4222

DESCRIPTION:
  • 4 inputs for resistance temperature measurement
  • For PT100 and PT1000
  • Configurable sensor type per channel
  • Direct resistance measurement
  • Configurable 2- or 3- wire connections per module
  • Configurable filter time

The module is equipped with 4 inputs for PT100/PT1000 resistance temperature measurement.

Short description
I/O module4 inputs for Pt100 or Pt1000 resistance temperature measurement
General information
B&R ID code0x1BA7
Status indicatorsI/O function per channel, operating state, module status
Diagnostics 
Module run/errorYes, using LED status indicator and software
InputsYes, using LED status indicator and software
Power consumption 
Bus0.01 W
Internal I/O1.1 W
Additional power dissipation caused by actuators (resistive) [W]-
Certifications 
CEYes
UKCAYes
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X
ULcULus E115267
Industrial control equipment
HazLoccCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5
DNVTemperature: B(0 - 55°C)
Humidity: B(up to 100%)
Vibration: B(4 g)
EMC: B(bridge and open deck)
LRENV1
KRYes
ABSYes
EACYes
KCYes
Resistance measurement temperature inputs
InputResistance measurement with constant current supply for 2- or 3-wire connections
Digital converter resolution16-bit
Filter timeConfigurable between 1 ms and 66.7 ms
Conversion time 
1 channel20 ms with 50 Hz filter
2 - 4 channels40 ms per channel with 50 Hz filter
Conversion procedureSigma-delta
Output formatINT or UINT for resistance measurement
Sensor 
Sensor typeConfigurable per channel
Pt100-200 to 850°C
Pt1000-200 to 850°C
Resistance measurement range0.1 to 4500 Ω / 0.05 to 2250 Ω
Input filterFirst-order low-pass filter / cutoff frequency 500 Hz
Sensor standardEN 60751
Common-mode range>0.7 V
Insulation voltage between channel and bus500 Veff
Linearization methodInternal
Measurement current250 µA ±1.25%
Reference4530 Ω ±0.1%
Permissible input signalShort-term max. ±30 V
Max. error at 25°C 
Gain0.037%
Offset0.0015%
Max. gain drift0.004%/°C
Max. offset drift0.00015%/°C
Nonlinearity<0.001%
Crosstalk between channels<-93 dB
Temperature sensor resolution 
Pt1001 LSB = 0.1°C
Pt10001 LSB = 0.1°C
Resistance measurement resolution 
G = 10.1 Ω
G = 20.05 Ω
Common-mode rejection 
50 Hz>80 dB
DC>95 dB
Standardized range of values for resistance measurement 
G = 10.1 to 4500 Ω
G = 20.05 to 2250 Ω
Temperature sensor normalization 
Pt100-200.0 to 850.0°C
Pt1000-200.0 to 850.0°C
Temperature measurement monitoring 
Range undershoot0x8001
Range overshoot0x7FFF
Open circuit0x7FFF
General fault0x8000
Open inputs0x7FFF
Resistance measurement monitoring 
Range overshoot0xFFFF
Open circuit0xFFFF
General fault0xFFFF
Open inputs0xFFFF
Electrical properties
Electrical isolationChannel isolated from bus
Channel not isolated from channel
Operating conditions
Mounting orientation 
HorizontalYes
VerticalYes
Installation elevation above sea level 
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature 
Operation 
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating-
Storage-40 to 85°C
Transport-40 to 85°C
Relative humidity 
Operation5 to 95%, non-condensing
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately.
Order 1x bus module X20BM11 separately.
Pitch12.5+0.2mm

 

 

Hot Products

07KR91 GJR5250000R0953 ABB 07KR91 07 KR 91 Central Processing Unit 24 VDC Product Details: Brand ...
07BA60 GJV3074397R1 ABB 07 BA 60 16 Integral Outputs Module 24 / 48 VDC Product Details: Brand Name ...
07BE60R1 GJV3074304R1 ABB 07 BE 60 R1 Slot Rack Programmable Logic Controller Product Details: Brand ...
07BV60 GJV3074370R1 ABB Module 07 BV 60 Bus Coupler Unit Module ABB Automation Product Details: ...
07DC92 GJR5252200R0101 ABB Module 07 DC 92 Digital I/O Module 24 VCD ABB Automation Product Details: ...
07EB61 GJV3074341R0001 ABB Module 07 EB 61 32 Integral Input Module 24 VCD ABB Automation Product ...