Home Companies Huge Technology Automation Co.,Ltd

X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC

Huge Technology Automation Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Unit 1602, Top Plaza, No.2 Lujiang Road, Siming District, Xiamen Fujian China

Contact name:Candy Wang

Inquir Now

Huge Technology Automation Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC

Country/Region china
City & Province xiamen fujian
Categories Chargers
InquireNow

Product Details

X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Safe Type A Digital Inputs, 4 Pulse Outputs, 24 VDC

MATERIAL NUMBER:

X20SI4100

DESCRIPTION:
  • 4 safe digital inputs
  • 4 pulse outputs
  • Sink circuit
  • Software input filter configurable for each channel

This module is equipped with 4 safe digital inputs. It is designed for a nominal voltage of 24 VDC.

The module can be used to read various digital signals in safety-related applications up to PL e or SIL 3.

The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line.

This module is designed for X20 12-pin terminal blocks.

Short description
I/O module4 safe type A digital inputs, 4 pulse outputs, 24 VDC
General information
B&R ID code0x1DBD
System requirements 
Automation Studio3.0.71 or later
Automation Runtime2.95 or later
SafeDESIGNER2.58 or later
Safety Release1.1 or later
mapp Technology Packagemapp Safety 5.7.0 or later
Status indicatorsI/O function per channel, operating state, module status
Diagnostics 
Module run/errorYes, using LED status indicator and software
InputsYes, using LED status indicator and software
Blackout mode 
ScopeModule
FunctionModule functionality
Standalone modeNo
Max. I/O cycle time800 µs
Power consumption 
Bus0.32 W
Internal I/O1.25 W
Additional power dissipation caused by actuators (resistive) [W]0.6
Electrical isolation 
Channel - BusYes
Channel - ChannelNo
Certifications 
CEYes
Functional safetycULus FSPC E361559
Energy and industrial systems
Certified for functional safety
ANSI UL 1998:2013
Functional safetyIEC 61508:2010, SIL 3
EN 62061:2013, SIL 3
EN ISO 13849-1:2015, Cat. 4 / PL e
IEC 61511:2004, SIL 3
Functional safetyEN 50156-1:2004
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X
ULcULus E115267
Industrial control equipment
HazLoccCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5
DNVTemperature: A(0 - 45°C)
Humidity: B(up to 100%)
Vibration: A(0.7 g)
EMC: B(bridge and open deck)
LRENV1
KRYes
ABSYes
EACYes
KCYes
Safety characteristics
EN ISO 13849-1:2015 
CategoryCat. 3 when using individual input channels,
Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
PLPL e
DC>94%
MTTFD2500 years
Mission timeMax. 20 years
IEC 61508:2010,
IEC 61511:2004,
EN 62061:2013
 
SIL CLSIL 3
SFF>90%
PFH / PFHd 
Per channel<1*10-10
openSAFETY wiredNegligible
openSAFETY wireless<1*10-14* Number of openSAFETY packets per hour
PFD<2*10-5
Proof test interval (PT)20 years
I/O power supply
Nominal voltage24 VDC
Voltage range24 VDC -15% / +20%
Integrated protectionReverse polarity protection
Safe digital inputs
Quantity4
VariantType A
Nominal voltage24 VDC
Input characteristics per EN 61131-2Type 1
Input filter 
Hardware≤150 μs
SoftwareConfigurable between 0 and 500 ms
Input circuitSink
Input voltage24 VDC -15% / +20%
Input current at 24 VDCMin. 2 mA to max. 4.59 mA. Hardware revision J0 and later: Min. 2 mA to max. 3.28 mA.
Input resistanceMin. 5.23 kΩ, hardware revision J0 and later: Min. 7.33 kΩ
Error detection time100 ms
Insulation voltage between channel and bus500 Veff
Switching threshold 
Low<5 VDC
High>15 VDC
Line length between signal source (pulse output or external signal) and inputMax. 60 m with unshielded line
Max. 400 m with shielded line
Pulse outputs
Quantity4
VariantPush-Pull
Nominal output current100 mA, hardware revision J0 and later: 50 mA
Output protectionThermal shutdown of all channels in the event of overload or short circuit,
hardware revision J0 and later: Shutdown of individual channels in the event of overload or short circuit
Peak short-circuit current300 mA, hardware revision J0 and later: 25 A for 15 µs
Short-circuit current100 mAeff
Leakage current when the output is switched off0.1 mA
RDS(on)60 Ω
Switching voltageI/O power supply minus voltage drop due to RDS(on)
Total nominal current400 mA, hardware revision J0 and later: 200 mA
Operating conditions
Mounting orientation 
HorizontalYes
VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Ambient conditions
Temperature 
Operation 
Horizontal mounting orientation0 to 60°C
Vertical mounting orientation0 to 50°C
DeratingSee section "Derating".
Storage-40 to 85°C
Transport-40 to 85°C
Relative humidity 
Operation5 to 95%, non-condensing
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x safety-keyed terminal block separately.
Order 1x safety-keyed bus module separately.
Pitch25+0.2mm

Hot Products

07KR91 GJR5250000R0953 ABB 07KR91 07 KR 91 Central Processing Unit 24 VDC Product Details: Brand ...
07BA60 GJV3074397R1 ABB 07 BA 60 16 Integral Outputs Module 24 / 48 VDC Product Details: Brand Name ...
07BE60R1 GJV3074304R1 ABB 07 BE 60 R1 Slot Rack Programmable Logic Controller Product Details: Brand ...
07BV60 GJV3074370R1 ABB Module 07 BV 60 Bus Coupler Unit Module ABB Automation Product Details: ...
07DC92 GJR5252200R0101 ABB Module 07 DC 92 Digital I/O Module 24 VCD ABB Automation Product Details: ...
07EB61 GJV3074341R0001 ABB Module 07 EB 61 32 Integral Input Module 24 VCD ABB Automation Product ...